Amplifier Research

Amplifier Research 20T4G18

4.2-18GHz 20W RF Amplifier
4 GHz – 18 GHz Frequency Range
20 Watts CW Minimum Output Power
50 dB (typical) Gain
±4 dB (typical) Gain Flatness
0 dBm (typical) Input Power for Rated Output
Request datasheet
Attribute Value
Frequency Range 4 GHz – 18 GHz
Minimum Output Power 20 Watts CW
Gain 50 dB (typical)
Gain Flatness ±4 dB (typical)
Input Power for Rated Output 0 dBm (typical)
Input/Output Impedance 50 Ohms
Input Connector SMA (female)
Output Connector 2.92mm (female)
Power Requirements 220 VAC, 50/60 Hz, Single Phase
Cooling Method Forced Air Cooling
Amplifier Research 20T4G18 Options:
  • 20T4G18 - M1 - E1C: Without outer enclosure (cabinet removed), size 48.3 x 13.3 (3U) x 68.6 cm
  • 20T4G18 - M2 - E1C, E2S & E3H: Without outer enclosure, slides installed, and front handles installed
  • 20T4G18 - M3 - E1C & S1R: Without outer enclosure, plus reflected power port (added Type N female connector on rear panel with forward and reflected sample port calibration data supplied on disk in Excel format at 51 points)
  • 20T4G18 - E1C - Cabinet: Without outer enclosure, size 48.3 x 13.3 (3U) x 68.6 cm, 19.0 x 5.25 (3U) x 27 in. Subtract approximately 9 kg, 20 lbs from weight
  • 20T4G18 - E2S - Slides: Slides installed, add approximately 2 kg, 5 lbs
  • 20T4G18 - E3H - Handles: Front handles installed
  • 20T4G18 - S1R - Reflected Power Port: Added Type N female connector on rear panel; forward and reflected sample port calibration data supplied on disk in Excel format at 51 points, evenly spaced over specified frequency response
Calibration Form Amplifier Research 20T4G18

Repair Form Amplifier Research 20T4G18
Maximum file size: 40MB

No Related Posts

More Information
Model20T4G18

The Amplifier Research 20T4G18A is a self-contained, forced air-cooled TWT microwave amplifier delivering a minimum of 20 watts at the output connector. It offers broadband performance with wide instantaneous bandwidth, high gain, and moderate power output. The digital front panel display provides forward and reflected output along with detailed system status including power, warm-up, standby, faults, and excess reflected power warnings. Standard features include IEEE-488 (GPIB) interface, VSWR protection, gain control, RF sample port, auto-sleep, and extensive monitoring of voltages, currents, and temperatures.

Designed for benchtop use but adaptable for rack mounting, the 20T4G18A is ideal for EMC susceptibility testing, industrial applications, and research & development in laboratories and universities.

Testwall can supply the used Amplifier Research 20T4G18A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Amplifier Research 20T4G18A.