Associated Research
Associated Research 3605
5 kV/20mA AC Hipot Tester
0 to 6 kVAC Test Voltage Range
200 mA Maximum Output Current
0.5 mA to 30 mA Trip Current Range
0.3 to 999 seconds Timer Range
50/60 Hz Frequency

| Attribute | Value |
|---|---|
| Test Voltage Range | 0 to 6 kVAC |
| Maximum Output Current | 200 mA |
| Trip Current Range | 0.5 mA to 30 mA |
| Timer Range | 0.3 to 999 seconds |
| Frequency | 50/60 Hz |
| Power Requirements | 115 VAC / 230 VAC, 50/60 Hz |
| Display | 4-Digit LED Display for Voltage and Current |
| Voltage Regulation | ±1% of full scale |
| Current Measurement Accuracy | ±2% of full scale |
| Dimensions (W x H x D) | 17 in x 7 in x 20 in (432 mm x 178 mm x 508 mm) |
Associated Research 3605 Options:
- 3605 - 38321 - Rack Mount Kit: Connects the instruments & provides the necessary flanges for mounting the system into a 19" rack
- 3605 - 35534 - Resistor Kit: Precision 1% resistor is ideal as a load to set current trip points. Meets 120 k ohm requirements
- 3605 - 35539 - Black Stationary Probe: Provides an insulated fixed metallic contact point to a DUT for a return path
- 3605 - 35822 - Foot Switch: Ideal for applications where an operator needs to start a test "hands off" the instrument
- 3605 - 38081 - Retractable Probe: High voltage retractable 5 KV AC probe for safe testing & application of high voltage
- 3605 - 38082 - Retractable Return Probe: This retractable probe is used on the return side of the Hypot III
- 3605 - 38083 - Safe-T-Probe: Test gun with trigger that controls retractable probe & activates instruments high voltage circuit
- 3605 - 36956 - Adjustable Resistor Bank: Provides test loads from 120 K to 2.148 k ohms. 6 terminals with 12 settings. Helps verify regulation
- 3605 - 260-01 - Interface Kit: Includes cables & adapter box so multiple tests can be performed through a single DUT
| Model | 3605 |
|---|
The 3605 is a manual 5KV AC Hipot tester with an enhanced graphic LCD. It can be used as a bench-top instrument or controlled through enhanced PLC Remote Control. It can also be interconnected to the HYAMP? III family of Ground Bond testers to form a complete test system that will perform AC Hipot and Ground Bond tests in a single DUT connection. It provides a simplified interface and the latest in technology & safety features. It is a perfect solution for entry level AC Hipot testing applications.
- Storage of up to 10 setups with 3 steps per setup
- Built-in security settings
- Digitally controlled arc detection system
- No load setup of trip current and output voltage
- Electronic ramping (up & down)
- Built-in adjustable continuity test