California Instruments

California Instruments 18000L

AC Power Supply
18,000 VA (18 kVA) Power Output
0 to 300 VAC (single phase), 0 to 150/300 VAC (split phase) Output Voltage Range
45 Hz to 1,000 Hz (DC to 5,000 Hz with extended option) Frequency Range
60 A RMS per phase Output Current (Max)
Single-phase or three-phase output (1Ø or 3Ø) Phase Configuration
Request datasheet
Attribute Value
Power Output 18,000 VA (18 kVA)
Output Voltage Range 0 to 300 VAC (single phase), 0 to 150/300 VAC (split phase)
Frequency Range 45 Hz to 1,000 Hz (DC to 5,000 Hz with extended option)
Output Current (Max) 60 A RMS per phase
Phase Configuration Single-phase or three-phase output (1Ø or 3Ø)
Total Harmonic Distortion (THD) Less than 0.5% THD at full resistive load
Input Voltage 208 VAC, 3-phase, 60 Hz
Programming Interface IEEE-488 (GPIB) and RS-232 interfaces standard
Output Regulation ±0.1% load regulation, ±0.1% line regulation
Operating Temperature 0°C to 40°C (32°F to 104°F)
California Instruments 18000L Options:
  • 18000L - P - Programmable controller (standard programmable, True RMS sensing)
  • 18000L - PT - Fast Transient programmable controller (real-time servo, fast settling)
  • 18000L - M - Manual control oscillator
  • 18000L - MODE - Allows IEEE-programmed or switch configured single-phase or three-phase output
  • 18000L - MT - Military applications controller option; CIIL and full confidence test
  • 18000L - RPV - Allows amplitude to be programmed with an external 0-10 VDC input (manual oscillator)
  • 18000L - SQW - Square wave capability with programmable controller
  • 18000L - 704 - MIL-STD-704 test routines embedded in -P and -PT controller
  • 18000L - 160 - RTCA/DO-160 test routines embedded in -PT controller
  • 18000L - HV - High voltage; changes output transformer to 156 V / 312 V, L-N
  • 18000L - EHV - Extra high voltage; changes output transformer to 200 V / 400 V, L-N (45 Hz to 1000 Hz only)
  • 18000L - LV - Low voltage; changes output transformer to 67.5 V / 135 V, L-N
  • 18000L - UP - Allows system to accept 3-phase L-L voltage from 342 V to 456 V, L-L
  • 18000L - LKM - Clock/Lock Master Unit; installs hardware to adapt to one slave unit
  • 18000L - LKS - Clock/Lock Slave Unit; installs hardware to accept Clock/Lock inputs from LKM unit
  • 18000L - 210960 - Rack slides; required for mounting in 19" (483 mm) instrument rack
Calibration Form California Instruments 18000L

Repair Form California Instruments 18000L
Maximum file size: 40MB

No Related Posts

More Information
Model18000L
California Instruments 18000L is an AC Power Supply
Clicky Copyright © 2025-present Magento, Inc. All rights reserved.