California Instruments
California Instruments 6000L-P/PT
AC Power Supply
6000 VA Power Output
0–300 VAC (single phase), 0–150/300 VAC programmable Output Voltage Range
45–1000 Hz Frequency Range
Up to 40 A RMS continuous Output Current (Max)
208 VAC, 3-phase Input Voltage

| Attribute | Value |
|---|---|
| Power Output | 6000 VA |
| Output Voltage Range | 0–300 VAC (single phase), 0–150/300 VAC programmable |
| Frequency Range | 45–1000 Hz |
| Output Current (Max) | Up to 40 A RMS continuous |
| Input Voltage | 208 VAC, 3-phase |
| Total Harmonic Distortion (THD) | Less than 0.5% at full resistive load |
| Voltage Regulation | 0.1% or better (load and line regulation) |
| Programming Interface | GPIB (IEEE-488) and RS-232 standard; optional LAN/USB |
| Waveform Capability | Sine wave; arbitrary waveform generation (with PT option) |
| Cooling Method | Forced air cooling |
California Instruments 6000L-P/PT Options:
- 6000L-P/PT - -HV - High voltage. Changes output transformer to 156 V/ 312 V, L-N
- 6000L-P/PT - -EHV - Extra high voltage. Changes output transformer to 200 V/ 400 V, L-N (45 Hz to 1000 Hz frequencies only)
- 6000L-P/PT - -LV - Low voltage. Changes output transformer to 67.5 V/ 135 V, L-N. Especially useful when 115 V, L-L is required
- 6000L-P/PT - -UP - Allows any system configured from Model 4500L and up to accept 3-phase L-L voltage from 342 V to 456 V, L-L
- 6000L-P/PT - -LKM - Clock/Lock Master Unit. Installs necessary hardware to adapt to one slave unit
- 6000L-P/PT - -LKS - Clock/Lock Slave Unit. Installs necessary hardware to accept Clock/Lock inputs from LKM unit. Only one slave unit may be driven from a master unit
- 6000L-P/PT - -MODE - Allows certain L-Series models to be IEEE-programmed or switch configured for single-phase or three phase output
- 6000L-P/PT - -MT - Primarily for military applications, where CIIL and full confidence test is required
- 6000L-P/PT - -704 - MIL-STD-704 test routines embedded in the -P and -PT controller along with the standard APE language
- 6000L-P/PT - -160 - RTCA/DO-160 test routines embedded in the -PT controller along with the standard APE language (not available on -P controller)
- 6000L-P/PT - 210960 - Rack slides. Required for mounting in 19" (483 mm) instrument rack
| Model | 6000L-P/PT |
|---|
The California Instruments 6000L-P/PT is an AC Power Supply