California Instruments

California Instruments 6000L-P/PT

AC Power Supply
6000 VA Power Output
0–300 VAC (single phase), 0–150/300 VAC programmable Output Voltage Range
45–1000 Hz Frequency Range
Up to 40 A RMS continuous Output Current (Max)
208 VAC, 3-phase Input Voltage
Request datasheet
Attribute Value
Power Output 6000 VA
Output Voltage Range 0–300 VAC (single phase), 0–150/300 VAC programmable
Frequency Range 45–1000 Hz
Output Current (Max) Up to 40 A RMS continuous
Input Voltage 208 VAC, 3-phase
Total Harmonic Distortion (THD) Less than 0.5% at full resistive load
Voltage Regulation 0.1% or better (load and line regulation)
Programming Interface GPIB (IEEE-488) and RS-232 standard; optional LAN/USB
Waveform Capability Sine wave; arbitrary waveform generation (with PT option)
Cooling Method Forced air cooling
California Instruments 6000L-P/PT Options:
  • 6000L-P/PT - -HV - High voltage. Changes output transformer to 156 V/ 312 V, L-N
  • 6000L-P/PT - -EHV - Extra high voltage. Changes output transformer to 200 V/ 400 V, L-N (45 Hz to 1000 Hz frequencies only)
  • 6000L-P/PT - -LV - Low voltage. Changes output transformer to 67.5 V/ 135 V, L-N. Especially useful when 115 V, L-L is required
  • 6000L-P/PT - -UP - Allows any system configured from Model 4500L and up to accept 3-phase L-L voltage from 342 V to 456 V, L-L
  • 6000L-P/PT - -LKM - Clock/Lock Master Unit. Installs necessary hardware to adapt to one slave unit
  • 6000L-P/PT - -LKS - Clock/Lock Slave Unit. Installs necessary hardware to accept Clock/Lock inputs from LKM unit. Only one slave unit may be driven from a master unit
  • 6000L-P/PT - -MODE - Allows certain L-Series models to be IEEE-programmed or switch configured for single-phase or three phase output
  • 6000L-P/PT - -MT - Primarily for military applications, where CIIL and full confidence test is required
  • 6000L-P/PT - -704 - MIL-STD-704 test routines embedded in the -P and -PT controller along with the standard APE language
  • 6000L-P/PT - -160 - RTCA/DO-160 test routines embedded in the -PT controller along with the standard APE language (not available on -P controller)
  • 6000L-P/PT - 210960 - Rack slides. Required for mounting in 19" (483 mm) instrument rack
Calibration Form California Instruments 6000L-P/PT

Repair Form California Instruments 6000L-P/PT
Maximum file size: 40MB

No Related Posts

More Information
Model6000L-P/PT
The California Instruments 6000L-P/PT is an AC Power Supply