Regenerative Grid Simulator, 12 kVA
0 – 300 Vrms (Single Phase), 0 – 150 Vrms (Split Phase) Output Voltage Range
15 Hz – 1000 Hz (Programmable) Output Frequency Range
12 kVA / 12 kW Output Power
40 Arms (Maximum per Phase) Output Current
1Ø / 2Ø (Single Phase / Split Phase Selectable) Phase Configuration
Request datasheet
Attribute Value
Output Voltage Range 0 – 300 Vrms (Single Phase), 0 – 150 Vrms (Split Phase)
Output Frequency Range 15 Hz – 1000 Hz (Programmable)
Output Power 12 kVA / 12 kW
Output Current 40 Arms (Maximum per Phase)
Phase Configuration 1Ø / 2Ø (Single Phase / Split Phase Selectable)
Total Harmonic Distortion (THD) ≤ 0.5% (Linear Load)
Input Voltage 200 / 208 / 220 / 230 / 240 Vac, 3-Phase
Input Frequency 47 Hz – 63 Hz
Waveform Sine Wave (Programmable Arbitrary Waveform Supported)
Interface / Connectivity GPIB, RS-232, USB, Ethernet (LAN)
Chroma 61812 Options:
  • 61812 - A618001 - Softpanel for 61800 Series
  • 61812 - A620039 - GPIB remote interface (option)
  • 61812 - A620045 - CAN remote interface (option)
Calibration Form Chroma 61812

Repair Form Chroma 61812
Maximum file size: 40MB

No Related Posts

More Information
Model61812

 CHROMA 61812 Regenerative Grid Simulator

 

The Chroma 61812 regenerative grid simulators have a power rating of 12kVA, and includes single phase and 3-phase operation.  With output voltage ranges up to 350VLN and 606VLL, each model can achieve 700VLN by a single phase 3-wire setup.  The total harmonic distortion rate is less than 0.5% at full load and 50Hz/60Hz output frequency. In addition to AC output, a DC output mode and AC plus DC output mode is included which can be expanded to DC test and AC test with DC bias voltage. The cur output capability can provide 3 times the RMS peak current, which is suitable for a DUT input inrush cur test.  

Chroma 61812 units are regenerative providing a complete energysaving solution. The power generated by the DUT during the test can be easily fed back to the grid, rather than dissipated as heat, which protects the environment and lowers the cost of operation.  For regulatory testing, 61812 grid simulators can be applied to IEC 61000-3-2/-3- 3/-3-11/-3-12, IEEE 1547/IEC 62116, electric vehicle to grid (V2G) testing, electric vehicle to load (V2L) testing, electric vehicle to home (V2H) testing, energy storage system (ESS) testing.  Remote interfaces include standard USB, LAN, and optional GPIB, CAN interface. Instruments can be controlled by computer and Chroma Softpanel software for fast digital operation.

 

Specifications for the  CHROMA 61812 Regenerative Grid Simulator Include:

Max Power (AC) 12kVA (4kVA per phase)
AC Voltage Range 0~350VLN / 0~606VLL
Max Power (DC) 12kW (4kW per phase)
DC Max Voltage 495V

 

 