Chroma
Chroma 63301A
DC Load Module, 80V, 40A, 200W
0 – 80 V Voltage Range
0 – 30 A Current Range
150 W Power Rating
CC, CV, CR, CP (Constant Current, Constant Voltage, Constant Resistance, Constant Power) Operating Modes
1 V at full current Minimum Operating Voltage

| Attribute | Value |
|---|---|
| Voltage Range | 0 – 80 V |
| Current Range | 0 – 30 A |
| Power Rating | 150 W |
| Operating Modes | CC, CV, CR, CP (Constant Current, Constant Voltage, Constant Resistance, Constant Power) |
| Minimum Operating Voltage | 1 V at full current |
| Input Connector | Binding Posts |
| Communication Interface | RS-232, GPIB (optional), USB (optional) |
| Display | LED Display for Voltage and Current |
| Protection Features | Over-voltage protection (OVP), Over-current protection (OCP), Over-power protection (OPP), Over-temperature protection (OTP), Reverse polarity protection |
| AC Input / Power Supply | 85 – 265 VAC, 47 – 63 Hz, Single Phase |
Chroma 63301A Options:
- 6332A - 6332A - Mainframe for 2 Load Modules
- 6334A - 6334A - Mainframe for 4 Load Modules
- 63302A - 63302A - Load Module 20A/80V/100Wx2 channels
- 63303A - 63303A - Load Module 60A/80V/300W
- 63305A - 63305A - Load Module 10A/500V/300W
- 63306A - 63306A - Load Module 120A/80V/600W
- 63307A - 63307A - Load Module 5A&40A/80V/30W&250W
- 63308A - 63308A - Load Module 20A/500V/600W
- 63312A - 63312A - Load Module 240A/80V/1200W
- 63310A - 63310A - Load Module 2A/500V/100Wx2 channels
- 63323A - 63323A - Load Module 60A/80V/350W
- 63301A - A631000 - GPIB Interface for Model 6334A/6332A Mainframe
- 63301A - A631003 - USB Interface for Model 6334A/6332A Mainframe
- 63301A - A631001 - Remote Controller
- 63301A - A800042 - Test Fixture
- 63301A - A631005 - Softpanel for 6310A/6330A series
- 63301A - A632004 - Sync. Link Box for 6330A/63200 Series
| Model | 63301A |
|---|
Chroma 63301A DC Electronic Load Module The Chroma Model 6330A series high speed DC electronic load improves CPU clock, baud rate, parser and added synchronic parallel function for fast operation. Each load is isolated and floating, programmable in dual cur range and measuring voltage range, and capable of synchronizing with other modules for control operating. Plugging the user selectable load modules into the Chroma 6332A/6334A system mainframes provide easy system configuration. With Synchronic parallel control capability, users can parallel and synchronize more than one load together from an internal loading control signal. Real time measurement of voltage, cur, is integrated into each Chroma 63301A load module using a 16-bit precision measurement circuit. The Chroma 63301A load modules have been enhanced for automated testing. Enhancements include synchronized paralleling allowing from transient response testing using parallel load groups and high speed data transfer circuits allowing for global queries of voltage and cur. It is also protected against OP, OC, OT, OV, and reverse polarity to guarantee quality and reliability for even the most demanding engineering testing and ATE application. Chroma 63301A DC Electronic Load Module Specifications: The Chroma 63301A load modules operate in constant cur, constant voltage, constant power or constant resistance to satisfy a wide range of test requirements (See data sheet for full specifications) For Use with the Chroma 6332A and Chroma 6334A