Datron/Wavetek 4808

| Attribute | Value |
|---|---|
| Calibration frequency | Recommended once a year |
| DC voltage | 0 to ±1100 V (±200 V with Opt 10; 1100 V with Opt 30) |
| AC voltage | 90 mV to 1100 V (200 V with Opt 20; 1100 V with Opt 30) |
| AC frequency range | 10 Hz to 1 MHz |
| Basic DC voltage uncertainty | 1 ppm (10 V range, 90-day, ±1 °C); 3 ppm (1-year, ±5 °C) |
| DC current | 0 to ±2 A (Opt 40); to 11 A with Opt 60 |
| AC current | 9 mA to 2 A, 10 Hz to 20 kHz (Opt 40); to 11 A with Opt 60 |
| Resistance | 10 Ω to 100 MΩ, decade values (Opt 50) |
| Wideband output | 10 Hz to 30 MHz, 300 mV to 3.5 V into 50 Ω (Opt 70) |
| Interface | IEEE-488 (GPIB) |
| Dimensions (H × W × D) | 178 × 455 × 563 mm |
| Weight | 36 kg |
| Power supply | 110/120/220/240 V ±10%, 48–62 Hz |
Datron/Wavetek 4808 Options:
- 4808 - Option 10 - DC Voltage (0 to ±200 V)
- 4808 - Option 20 - AC Voltage (90 mV to 200 V, 10 Hz to 1 MHz)
- 4808 - Option 30 - High Voltage Amplifier (DC/AC to 1100 V; requires Option 10 or 20)
- 4808 - Option 40 - DC Current (0 to ±2 A) and AC Current (9 mA to 2 A)
- 4808 - Option 50 - Resistance (10 Ω to 100 MΩ, decade values)
- 4808 - Option 60 - Model 4600 Transconductance Amplifier (DC/AC current to 11 A; requires Option 40)
- 4808 - Option 70 - Wideband AC Voltage (10 Hz to 30 MHz, 300 mV to 3.5 V into 50 Ω; requires Option 20)
- 4808 - Option 90 - Rack Mounting Kit
The Datron/Wavetek 4808 is a high-stability multifunction calibrator built for standards laboratories that calibrate precision digital multimeters up to 8½ digits. Fully optioned, it sources DC voltage to ±1100 V, AC voltage from 90 mV to 1100 V over 10 Hz to 1 MHz, DC and AC current to 2 A (11 A with the 4600 transconductance amplifier) and decade resistance from 10 Ω to 100 MΩ. On the 10 V range, DC voltage uncertainty is 1 ppm of output over 90 days (±1 °C).
The 4808 is modular: Option 10 (DC voltage), 20 (AC voltage), 30 (1100 V amplifier), 40 (current), 50 (resistance), 60 (4600 amplifier, 11 A) and 70 (wideband output to 30 MHz) can be combined, so please check the installed options on the unit offered. Spot-frequency calibration, error and offset modes, remote guard and sense, and IEEE-488 control make it well suited to automated calibration systems, and it is supported by the Wavetek 4950 Multifunction Transfer Standard. The Datron/Wavetek line is now part of Fluke Calibration, and the 4808 has been discontinued.
Testwall can supply the used Datron/Wavetek 4808, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Datron/Wavetek 4808.