Anritsu MA2473A

| Attribut | Wert |
|---|---|
| Frequenzbereich | 10 MHz – 18 GHz |
| Messbereich | -70 dBm bis +20 dBm |
| Sensortyp | Diodensensor (CW) |
| Anschlusstyp | 2,92 mm (K-Typ) |
| VSWR | ≤ 1,35 (typisch) |
| Kalibrierfrequenz | 50 MHz |
| Kalibrierausgangsleistung | 1 mW (0 dBm) |
| Impedanz | 50 Ohm |
| Betriebstemperaturbereich | 0 °C bis +55 °C |
| Kompatible Leistungsmessgeräte | Anritsu ML2430A-Serie, ML2480B-Serie |
Anritsu MA2473A Options:
- MA2473A - MA2473D - Standard Diode Sensor, 10 MHz to 32 GHz, K(m) connector
- ML2490A - 06 - Rear Mount Input A
- ML2490A - 07 - Rear Input A and Reference
- ML2490A - 08 - Rear Mount Inputs A, B and Reference
- ML2490A - 09 - Rear Mount Inputs A and B
- ML2490A - 33 - Extra Operating Manual
- ML2490A - 34 - Extra Programming Manual
- ML2490A - 37 - Electronic Manuals (deletes paper version from shipment)
- ML2490A - 98 - Calibration to Z540, ISO Guide 25
- ML2490A - 99 - Premium Calibration
- ML2480A - 06 - Rear Mount Input A
- ML2480A - 07 - Rear Input A and Reference
- ML2480A - 08 - Rear Mount Inputs A, B and Reference
- ML2480A - 09 - Rear Mount Inputs A and B
- ML2480A - 15 - Factory Fitted 50MHz and 1GHz Calibrator (required by MA2411B Sensor)
- ML2480A - 15R - Retro Fit Calibrator Kit
- ML2480A - 33 - Extra Operating Manual ML2487/8A
- ML2480A - 34 - Extra Programming Manual ML2487/8A
- ML2480A - 35 - Extra Operating Manual: Japanese
- ML2480A - 36 - Extra Programming Manual: Japanese
- ML2480A - 37 - Electronic Manuals only (deletes paper version from shipment)
- ML2480A - 98 - Calibration to Z540, ISO Guide 25
- ML2480A - 99 - Premium Calibration
- ML2400A - 32A - Maintenance Manual ML2480/90A Series
- ML2400A - 31A - Option 31, Extra Operation/Prog manual ML2480A
- ML2400A - 10585-00003 - Maintenance Manual ML2400A Series
- ML2400A - 33 - Extra Operating & Programming Manual ML2437/8A
- MA2499B - MA2499B - Anritsu 4700 & 4600 Series Sensor Adapter
- ML2400A - 06 - Rear Mount Input A on ML2437A
- ML2400A - 07 - Rear Input A and Reference on ML2437A
- ML2400A - 08 - Rear Mount Inputs A, B and Reference
- ML2400A - 09 - Rear Mount Inputs A and B on ML2438A
- ML2400A - 11 - NiMH Battery with Desktop Charger
- ML2400A - 11A - NiMH Battery with Desktop Charger (for use in Japan only)
- ML2400A - 22 - 3m Sensor Cable
- ML2400A - 23 - 5m Sensor Cable
- ML2400A - 24 - 10m Sensor Cable
- ML2400A - 25 - 30m Sensor Cable
- ML2400A - 26 - 50m Sensor Cable
- ML2400A - 27 - 100m Sensor Cable
- ML2400A - 30 - Extra Operation Manual ML2437/8A
- ML2400A - 98 - Calibration to Z540, ISO Guide 25
- ML2400A - 99 - Premium Calibration
- ML2400A - 30A - Option 30, Extra Operation/Prog manual (For use in Japan, only)
- MA2473A - 760-209 - Hardside Transit Case
- MA2473A - D41310 - Soft Carry Case with Shoulder Strap
- MA2473A - MA2418A - 50 MHz Reference Oscillator with Power Supply
- MA2473A - ML2400A-01 - Rack Mount, single unit
- MA2473A - ML2400A-03 - Rack Mount, side by side
- MA2473A - ML2400A-05 - Front Bail Handle
- MA2473A - ML2400A-12 - Front Panel Cover
- MA2473A - ML2400A-20 - Spare 1.5m Sensor Cable
- MA2473A - ML2400A-21 - 0.3m Sensor Cable
- MA2473A - ML2400A-28 - RS232 Bootload Cable
- MA2473A - ML2400A-29 - Bulkhead Adapter
- MA2473A - ML2419A - Range Calibrator
- MA2473A - MA2497A - Agilent/HP84xxA Series Sensor Adaptor
| Model | MA2473A |
|---|
Das Anritsu MA2473A ist für Hochfrequenz-RF-Diagnosen konzipiert und deckt 10 MHz bis 32 GHz mit einem außergewöhnlichen Dynamikbereich von –70 dBm bis +20 dBm (~90 dB) ab. Es bietet Breitbandleistung, schnelle Dioden-Messlogik und in EEPROM gespeicherte Kalibrierkonstanten für konsistente Präzision.
Ideal für Luft- und Raumfahrt, Telekommunikation und fortschrittliche RF-Tests unterstützt das Anritsu MA2473A sowohl CW- als auch gepulste Signale und gewährleistet Zuverlässigkeit in anspruchsvollen Umgebungen.
Testwall kann das gebrauchte Anritsu MA2473A liefern, vollständig getestet. Mit fachkundiger Unterstützung und weltweiter Lieferung gewährleistet Testwall Hochleistungsinstrumentierung mit unübertroffener Zuverlässigkeit und Servicequalität. Bitte kontaktieren Sie uns direkt, wenn Sie eine Kalibrierung oder Reparatur des Anritsu MA2473A benötigen.