Anritsu MG3697C

| Attribut | Wert |
|---|---|
| Frequenzbereich | 2 kHz – 67 GHz |
| Ausgangsleistung | +20 dBm (typisch) |
| Frequenzauflösung | 0,001 Hz |
| Phasenrauschen | -115 dBc/Hz bei 10 kHz Abstand (typisch) |
| Modulationsarten | AM, FM, ΦM, Puls, I/Q |
| Spektrale Reinheit | Harmonische besser als -55 dBc |
| Ausgangsimpedanz | 50 Ohm |
| Frequenzumschaltzeit | Weniger als 5 ms (typisch) |
| Stromversorgung | 100–240 V AC, 50/60 Hz |
| Betriebstemperaturbereich | 0 °C bis +55 °C |
Anritsu MG3697C Options:
- MG3697C - 1A - Rack Mount with slides. Rack mount kit containing a set of track slides, mounting ears, and front panel handles to let the instrument be mounted in a standard 19-inch equipment rack.
- MG3697C - 1B - Rack Mount without slides. Modifies rack mounting hardware to install unit in a console that has mounting shelves. Includes mounting ears and front panel handles.
- MG3697C - 2C - Mechanical Step Attenuator. Adds a 10 dB/step attenuator. Rated RF output power is reduced.
- MG3697C - 3 - Ultra Low Phase Noise. Adds new modules to significantly reduce SSB phase noise. Not available with Option 3X.
- MG3697C - 3X - Premium Phase Noise. Improves Option 3 < 1 kHz offset. Not available with Option 3.
- MG3697C - 15D - High Power. Adds high-power RF components to the instrument to increase its output power level.
- MG3697C - 16 - High Stability Time Base. Adds an ovenized, 10 MHz crystal oscillator as a high-stability time base.
- MG3697C - 17 - Delete Front Panel. Deletes the front panel for use in remote control applications where a front panel display and keyboard control are not needed. Only available with Options 1A or 1B.
- MG3697C - 22 - 0.1 Hz to 10 MHz Audio coverage. Uses a DDS for coverage down to approximately DC. Output power is derated by 2 dB. Frequency resolution below 10 MHz is 0.02 Hz. No modulation available in the 0.1 Hz to 10 MHz band. Not available without Option 4 or 5.
- MG3697C - 26B - Pulse Modulation. External, via a rear panel BNC connector. For internal modulation capability, requires addition of a Pulse Generator, Option 27.
- MG3697C - 27 - Internal LF and Pulse Generators. Provides modulation waveforms for internal AM (if Option 14 installed), FM (if Option 12 installed), PM (if Option 12 installed) and Pulse (if Option 26A/B installed). Not available without Option 12, 14, or 26.
- MG3697C - 28B - Analog Modulation Suite. Bundles Options 12, 14, 26 and 27, offering internally- and externally-driven AM, FM, PM, and Pulse Modulation.
- MG3697C - 36 - Ultra-Stable Phase Tracking. Provides the capability for ultra-stable phase tracking between instruments using the internal 100 MHz reference. Requires Option 3 or 3X.
- MG3697C - CE - CE Compliance with CE mark.
- MG3697C - 98 - Standard Calibration to ISO17025 and ANSI/NCSL Z540-1. Provides a calibration certificate, decal, and "Calibration void if removed" tamper seals.
- MG3697C - 99 - Premium Calibration to ISO17025 and ANSI/NCSL Z540-1. Provides everything included with Option 98 plus test report and uncertainty data.
| Model | MG3697C |
|---|
Der Anritsu MG3697C ist ein Hochleistungs-Signalgenerator mit erweiterten Funktionen wie gespeicherten Setups, Speicher-Sequenzierung, Master/Slave-Betrieb und präziser Ebenheitskorrektur auf Benutzerebene. Er unterstützt interne und externe Zeitbasis-Kalibrierung mit einer Stabilität von <2 x 10⁻⁹/Tag und bietet eine Auflösung bis zu 0,01 Hz. Mit sicherem Modus, vielseitiger Parametereingabe und umfassenden Sweep-Funktionen gewährleistet er Genauigkeit und Flexibilität in anspruchsvollen Anwendungen.
Mit vielfältigen Sweep-Optionen, benutzerdefinierten Schritten und schneller Haltezeitregelung ist der Anritsu MG3697C ideal für HF-Tests, Kommunikation und Signalanalyse. Er verfügt außerdem über Selbsttest-Diagnosen und unterstützt mehrere Leistungsmessgeräte für präzise Wegkorrekturen.
Testwall kann den gebrauchten Anritsu MG3697C liefern, vollständig getestet. Mit fachkundiger Unterstützung und weltweiter Lieferung bietet Testwall leistungsstarke Messtechnik mit höchster Zuverlässigkeit und Servicequalität. Bitte kontaktieren Sie uns direkt, wenn Sie eine Kalibrierung oder Reparatur des Anritsu MG3697C benötigen.