Chroma 62015B-80-18

HerstellerChroma
Modell62015B-80-18
ProduktDC Power Supply Module, 80V, 18A, 1440W
TypGebraucht

 

Chroma 62015B-60-25

Chroma 62015B-60-25

Chroma 62020H-150S

Chroma 62020H-150S

Holen Sie sich ein Angebot
SKU
122775
Chroma 62015B-80-18 The Chroma 62015B-80-18 DC Power Supply Module, with its many unique features, is designed for burn-in applications such as the LCD panels, DC-DC converters, power inverters, notebook computers, battery chargers and many other typs of electronic devices.  Its high power density and low cur ripple make it very cost effective. Designed with Modern power factor correction circuitry it meets IEC requirements.
 
Features and Specifications of the Chroma 62015B-80-18 DC Power Supply Module include:
  • Features:
    • N+1 Redundancy
    • Hot-Swappable Maintenance
    • Ideal for Burn-in and Plating
    • High Power Applications with CSU
    • Remote Sense
    • Remote ON / OFF
    • CAN Bus Control
    • DC OK Signal Output
    • Voltage range: 1 ~ 80V
    • Cur range: Up to 2000A (System)
    • Power range up to 1.5KW per module up to 120KW per system
    • High Power Density (464 mW / cm3 = 7.13 W/In3)
  • Specifications:
    • Electrical Specifications:
      • Output Ratings:
        • Output Power:  1440W
        • Output Voltage:  1~80V
        • Output Cur:  1~18A
      • LIne Regulation:  0.1% FS
      • Load Regulation:  1% FS
      • Programming Accuracy:  1% FS
      • Measurement Accuracy:  1% FS
      • Output Noise (20MHz):
        • Voltage Noised (P-P):  200mV
        • Voltage Ripple (rms):  50mV
        • Cur Ripple (rms):  0.18A
      • Efficiency:  > 88% @ full load
      • Turn On Over Shoot Voltage (Rise Time of 100ms):  5% of nominal output
      • Transient Response Time:  < 5 ms
      • AC Input Voltage:
        • Six Position Mainframe:  187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) / 45 ~ 65 Hz
        • Three Position Mainframe:  187 to 250 Vac (single phase) / 45 ~ 65 Hz
        • Input Power Factor:  > 0.98@ full load
    • Protection Function:
      • OVP:  Automatically shuts down at 115% of set value
      • Adjustment Range:  1~83V
      • OCP:  Cur limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
      • OTP:  Automatically shuts down if internal limit is reached
    • I/O Signal:
      • Remote ON/OFF (I/P):  Dry contact (closed = enabled), vice versa
      • AUX Voltage:  4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
      • DC OK Signal Type (O/P):  Dry contact (closed = enabled) (Error : OVP / OCP / OTP / AC Fault)
    • Programming Response Time (Six Position Mainframe through CAN) (Typical):
      • Rise Time (Full Load):  For a programmed 5% to 95% step in output voltage : 100ms
      • Rise Time (No Load):  For a programmed 5% to 95% step in output voltage : 100ms
      • Fall Time (Full Load):  For a programmed 95% to 5% step in output voltage : 40ms
      • Fall Time (No Load):  For a programmed 95% to 5% step in output voltage : 5s
      • Vout Setting:  CAN Bus send command to DC module receiver : 1s
      • Measurement V & I:  Under CAN command using fetch : 100ms
      • Delay Time:  For output ON/OFF enable and disable (under CAN command) : 5s(Single Mainframe)
    • General Specifications:
      • Remote Sensing:  3V maximum line loss compensation
      • Parallel Operation:  Cur Sharing (±5%)
      • Operating Temperature:  0 ~ 50°C
      • Humidity Range:  0 ~ 90% RH. Non-condensing
      • Remote Interface:  CAN Bus (optional)
      • Safety & EMC:  CE
  • N+1 Redundancy
  • Hot-Swappable Maintenance
  • Ideal for Burn-in and Plating
  • High Power Applications with CSU
  • Remote Sense
  • Remote ON / OFF
  • CAN Bus Control
  • DC OK Signal Output
  • Voltage range: 1 ~ 80V
  • Cur range: Up to 2000A (System)
  • Power range up to 1.5KW per module up to 120KW per system
  • High Power Density (464 mW / cm3 = 7.13 W/In3)
  • Electrical Specifications:
    • Output Ratings:
      • Output Power:  1440W
      • Output Voltage:  1~80V
      • Output Cur:  1~18A
    • LIne Regulation:  0.1% FS
    • Load Regulation:  1% FS
    • Programming Accuracy:  1% FS
    • Measurement Accuracy:  1% FS
    • Output Noise (20MHz):
      • Voltage Noised (P-P):  200mV
      • Voltage Ripple (rms):  50mV
      • Cur Ripple (rms):  0.18A
    • Efficiency:  > 88% @ full load
    • Turn On Over Shoot Voltage (Rise Time of 100ms):  5% of nominal output
    • Transient Response Time:  < 5 ms
    • AC Input Voltage:
      • Six Position Mainframe:  187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) / 45 ~ 65 Hz
      • Three Position Mainframe:  187 to 250 Vac (single phase) / 45 ~ 65 Hz
      • Input Power Factor:  > 0.98@ full load
  • Protection Function:
    • OVP:  Automatically shuts down at 115% of set value
    • Adjustment Range:  1~83V
    • OCP:  Cur limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
    • OTP:  Automatically shuts down if internal limit is reached
  • I/O Signal:
    • Remote ON/OFF (I/P):  Dry contact (closed = enabled), vice versa
    • AUX Voltage:  4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
    • DC OK Signal Type (O/P):  Dry contact (closed = enabled) (Error : OVP / OCP / OTP / AC Fault)
  • Programming Response Time (Six Position Mainframe through CAN) (Typical):
    • Rise Time (Full Load):  For a programmed 5% to 95% step in output voltage : 100ms
    • Rise Time (No Load):  For a programmed 5% to 95% step in output voltage : 100ms
    • Fall Time (Full Load):  For a programmed 95% to 5% step in output voltage : 40ms
    • Fall Time (No Load):  For a programmed 95% to 5% step in output voltage : 5s
    • Vout Setting:  CAN Bus send command to DC module receiver : 1s
    • Measurement V & I:  Under CAN command using fetch : 100ms
    • Delay Time:  For output ON/OFF enable and disable (under CAN command) : 5s(Single Mainframe)
  • General Specifications:
    • Remote Sensing:  3V maximum line loss compensation
    • Parallel Operation:  Cur Sharing (±5%)
    • Operating Temperature:  0 ~ 50°C
    • Humidity Range:  0 ~ 90% RH. Non-condensing
    • Remote Interface:  CAN Bus (optional)
    • Safety & EMC:  CE
  • Output Ratings:
    • Output Power:  1440W
    • Output Voltage:  1~80V
    • Output Cur:  1~18A
  • LIne Regulation:  0.1% FS
  • Load Regulation:  1% FS
  • Programming Accuracy:  1% FS
  • Measurement Accuracy:  1% FS
  • Output Noise (20MHz):
    • Voltage Noised (P-P):  200mV
    • Voltage Ripple (rms):  50mV
    • Cur Ripple (rms):  0.18A
  • Efficiency:  > 88% @ full load
  • Turn On Over Shoot Voltage (Rise Time of 100ms):  5% of nominal output
  • Transient Response Time:  < 5 ms
  • AC Input Voltage:
    • Six Position Mainframe:  187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) / 45 ~ 65 Hz
    • Three Position Mainframe:  187 to 250 Vac (single phase) / 45 ~ 65 Hz
    • Input Power Factor:  > 0.98@ full load
  • Output Power:  1440W
  • Output Voltage:  1~80V
  • Output Cur:  1~18A
  • Voltage Noised (P-P):  200mV
  • Voltage Ripple (rms):  50mV
  • Cur Ripple (rms):  0.18A
  • Six Position Mainframe:  187 ~ 250 Vac (3 Phase 4 Wire, Δ Connection ) or 323 ~ 437 Vac (3 Phase 5 Wire, Y Connection) / 45 ~ 65 Hz
  • Three Position Mainframe:  187 to 250 Vac (single phase) / 45 ~ 65 Hz
  • Input Power Factor:  > 0.98@ full load
  • OVP:  Automatically shuts down at 115% of set value
  • Adjustment Range:  1~83V
  • OCP:  Cur limit (0 ~ 100%) / OCP Shutdown at 115% of F.S.
  • OTP:  Automatically shuts down if internal limit is reached
  • Remote ON/OFF (I/P):  Dry contact (closed = enabled), vice versa
  • AUX Voltage:  4 ~ 24V / 0.5A at mainframe (by trimmer adjust voltage)
  • DC OK Signal Type (O/P):  Dry contact (closed = enabled) (Error : OVP / OCP / OTP / AC Fault)
  • Rise Time (Full Load):  For a programmed 5% to 95% step in output voltage : 100ms
  • Rise Time (No Load):  For a programmed 5% to 95% step in output voltage : 100ms
  • Fall Time (Full Load):  For a programmed 95% to 5% step in output voltage : 40ms
  • Fall Time (No Load):  For a programmed 95% to 5% step in output voltage : 5s
  • Vout Setting:  CAN Bus send command to DC module receiver : 1s
  • Measurement V & I:  Under CAN command using fetch : 100ms
  • Delay Time:  For output ON/OFF enable and disable (under CAN command) : 5s(Single Mainframe)
  • Remote Sensing:  3V maximum line loss compensation
  • Parallel Operation:  Cur Sharing (±5%)
  • Operating Temperature:  0 ~ 50°C
  • Humidity Range:  0 ~ 90% RH. Non-condensing
  • Remote Interface:  CAN Bus (optional)
  • Safety & EMC:  CE
  •     

    Keine verwandten Beiträge

    Rückgaben

    Wenn Sie mit Ihrem Kauf nicht vollständig zufrieden sind, senden Sie den Artikel einfach innerhalb von 30 Tagen nach Erhalt in seinem Originalzustand an uns zurück. Zurückgesandte Artikel müssen unbenutzt sein und in der Originalverpackung mit allen beigefügten Unterlagen zurückgeschickt werden. Nach Erhalt erstatten wir Ihnen den vollen Betrag, abzüglich der ursprünglichen Lieferkosten. Alternativ tauschen wir den Artikel gerne um, wenn Sie dies bevorzugen.