Druck PV621G Options:
- PV621G - IO620-BATTERY - DPI620G Spare/rechargeable lithium polymer battery (not compatible with DPI620G-IS models)
- PV621G - IO620-PSU - DPI620G Spare/replacement universal mains adapter. Input voltage 100 to 240 VAC 50/60 Hz
- PV621G - IO620-CHARGER - DPI620G Battery charging station
- PV621G - IO624-Battery - Rechargeable PV624 battery pack
- PV621G - IO624-CHGR-KIT-UK - PV624 external desktop battery charger with UK Plug
- PV621G - IO624-CHGR-KIT-EU - PV624 external desktop battery charger with EU Plug
- PV621G - IO624-CHGR-KIT-US - PV624 external desktop battery charger with US Plug
- PV621G - IO624-CHGR-KIT-AU - PV624 external desktop battery charger with Australia Plug
- PV621G - IO624-CHGR-KIT-CN - PV624 external desktop battery charger with China Plug
- PV621G - IO620-AC - Replacement AC voltage measurement probe. Attaches to the DPI620G, 30 V sockets to provide 300 VAC true rms measurement
- PV621G - IO620-CASE-1 - DPI620G carrying case. Protective carrying case with belt loop, shoulder strap and large detachable pocket for test leads and accessories
- PV621G - IO620-CASE-2 - System carrying case. Protective carrying case for system components including the DPI620G, MC620G, PM620 modules, test leads, hose and adapters
- PV621G - IO620-USB-PC - USB cable. Connects the DPI620G or DPI620G-IS to a PC
- PV621G - IO620-IDOS-USB - IDOS to USB converter. Allows connection of an IDOS universal pressure module to the DPI620G
- PV621G - IO620-USB-RS232 - USB to RS 232 cable. Connects the DPI620G to an RS 232 interface
- PV621G - IO620-PRV-P1 - Pressure relief valve for PV621G/PV622G. Factory setting 1 bar (15 psi), adjustable range 0.2 to 1 bar (3 to 15 psi)
- PV621G - IO620-PRV-P2 - Pressure relief valve for PV621G/PV622G. Factory setting 5 bar (100 psi), adjustable range 3 to 7 bar (45 to 100 psi)
- PV621G - IO620-PRV-P3 - Pressure relief valve for PV621G/PV622G. Factory setting 30 bar (435 psi), adjustable range 16 to 32 bar (230 to 460 psi)
- PV621G - IO620-PRV-P6 - Pressure relief valve for PV621G/PV622G. Factory setting 3 bar (45 psi), adjustable range 1.1 to 3 bar (16 to 45 psi)
- PV621G - IO620-PRV-P7 - Pressure relief valve for PV621G/PV622G. Factory setting 12 bar (170 psi), adjustable range 6.1 to 12 bar (90 to 170 psi)
- PV621G - IO620-PRV-P8 - Pressure relief valve for PV621G/PV622G. Factory setting 18 bar (260 psi), adjustable range 12.1 to 18 bar (175 to 260 psi)
- PV621G - IO620-RAK-5U - Rack mount Kit. Enables the DPI620G to be mounted in a 5U 19" half rack
- PV621G - IO620-RAK-8U - Rack mount Kit. Enables the DPI620G to be mounted in a 8U 19" half rack
- PV621G - IO620-RAK-MC - Rack mount Kit. Enables the DPI620G + MC620 to be mounted in a 8U 19" half rack
- PV621G - IO620-IDT621 - Dirt moisture trap. Maximum working pressure 35 bar (500 psi)
- PV621G - IO620-IDT622 - Dirt moisture trap. Maximum working pressure 100 bar (1,500 psi)
- PV621G - IO620-CASE-3 - Pressure base station carrying case for safe area use
- PV621G - IO620-CASE-4 - Modular system transit case. Rigid transit case with wheels and extendable handle
- PV621G - IOHOSE-NP1 - 1 m/3.28 ft pneumatic hose. Maximum pressure 20 bar/300 psi
- PV621G - IOHOSE-NP2 - 2 m/6.56 ft pneumatic hose. Maximum pressure 20 bar/300 psi
- PV621G - IO620-HOSE-P1 - 1 m/3.28 ft pneumatic hose. Maximum pressure 400 bar (5,800 psi)
- PV621G - IO620-HOSE-P2 - 2 m/6.56 ft pneumatic hose. Maximum pressure 400 bar (5,800 psi)
- PV621G - IO620-HOSE-H1 - 1 m/3.28 ft hydraulic hose rated to 1,000 bar (15,000 psi)
- PV621G - IO620-HOSE-H2 - 2 m/6.56 ft hydraulic hose rated to 1,000 bar (15,000 psi)
- PV621G - IO620-BSP - Pressure adapter set: G1/8 male and G¼ male, G¼ female, G3/8 female and G½ female
- PV621G - IO620-NPT - Pressure adapter set: 1/8" male and ¼" male, ¼" female, 3/8" female, and ½" female
- PV621G - IO620-MET - Pressure adapter set: 14 mm and 20 mm female
- PV621G - IO620-COMP-NEW - Comparator adapter. Allows the PV62XG pressure station to be used as a comparator
- PV621G - IO620-BLANK - Blanking plug. Allows the PV621G and 622G to be used as pressure generators independently of the DPI620G and PM620
- PV621G - IO620-104 ADAPT - DPI 104 gauge adaptor. Allows a DPI 104 digital pressure gauge to be connected to the PV62XG pressure module port
| Model | PV621G |
|---|
Druck PV621G 300 PSI Pneumatic Station for Genii
Druck PV621G 300 PSI Pneumatic Station for Genii is a high performance pressure-generating station which can generate pressure quickly and efficiently, without the need for system priming. This station is ATEX approved for stand-alone use in hazardous areas and designed for easy transportation and use in various settings. When combined with a reference instrument, such as the DPI104, Druck PV621G 300 PSI Pneumatic Station can be used as gauge comparator and pressure calibrator.
Druck PV621G 300 PSI Pneumatic Station have been designed for use with the DPI620 Genii, the advanced multifunction calibrator and PM620 interchangeable pressure modules to provide a multi-parameter calibration system with unique pressure generation and measurement capabilities. Druck PV621G 300 PSI Pneumatic Station has a conventional hand pump, volume adjuster and pressure/vacuum selector, but will generate pressure with half the effort of conventional systems. It is suitable for wide range of pressure instruments, including pressure gauges, transmitters, and switches.
Specifications for the Druck PV621G 300 PSI Pneumatic Station for Genii Include:
| Maximum pressure | 20 bar (300 psi) pneumatic |
| Pressure media | Non-corrosive gases |
| Operating temperature | -10 ° to 50 °C (14 ° to 122 °F) |
| Shock and vibration | BS EN 61010-1:2010; MIL-PRF-28800F for Class II equipment, 1 m drop tested |