EMC Partner AVI3000
Lightning Generator Test System, DO-160, MIL-STD-461G
bis zu 3000 V Ausgangsspannung
IEC 61000-4-5, IEEE C62.41, ANSI C62.45 Prüfnormen
Kombinationswelle 1,2/50 µs – 8/20 µs Wellenform
2 Ω (Kombination) Ausgangsimpedanz
200 J Maximale Ausgangsenergie

| Attribut | Wert |
|---|---|
| Ausgangsspannung | bis zu 3000 V |
| Prüfnormen | IEC 61000-4-5, IEEE C62.41, ANSI C62.45 |
| Wellenform | Kombinationswelle 1,2/50 µs – 8/20 µs |
| Ausgangsimpedanz | 2 Ω (Kombination) |
| Maximale Ausgangsenergie | 200 J |
| Wiederholrate | bis zu 60 Impulse pro Minute |
| Phasensynchronisation | 0° – 360°, einstellbar |
| Schnittstellen | RS-232, USB, optional IEEE 488 (GPIB) |
| Betriebstemperatur | 0 °C bis +40 °C |
| Versorgungsspannung | 230 V AC, 50/60 Hz |
| Model | Partner |
|---|
EMC Partner AVI3000 (call to schedule availability)The EMC PARTNER AVI3000 Indirect Lighting Generator is a state of the art test system for DO-160 section 22 and MIL-STD-461 CS117. Full compliance up to level 3 for PIN injection and Cable bundle tests including Single Stroke, Multiple stroke and Multiple Bursts. Complies with CS117 test levels for internal equipment. Tests are programmed from the user friendly color touch panel controls. A single coupler with aperture 5.5cm x 8cm transfers all 6 waveforms into the EUT. Cables only need to pass once through the core to achieve full Level 3 threat under all possible conditions. Complimented by the TEMA3000 software suite, the EMC Partner AVI3000 is truly remarkable and deserves the accolade best in class.DO-160 level 3 and MIL-STD-461 CS117 Internal test system. Waveforms included: 1, 2, 3, 4, 5A, 6. Applications: PIN, CB, GI V/I ranges for Single Pulse, Multiple Pulses and Burst, see Technical Specifications and Brochure of AVI3000. Features of the EMC Partner AVI3000 include: Comfortable Touchscreen Menu - Easy Navigation All 6 waveforms in one unit Full level 3 threat unter all laod conditions Phase angle synchronisation to 800Hz Integrated AC/DC de-couplers for powered PIN testing Benefits include: Man portable unit for on-site testing Automated test process, no need to change generator More efficient testing with less user intervention. Full compliance testing without additional hardware Increased system availability, higher throughput Impulses/Circuits: WF1 (6.4/69) WF2 (0.1/6.4) WF3 (1MHz/10MHz) WF4 (6.4/69) WF5A (40/120) WF6 (0.25 /4) Standards include: RTCA DO-160 - Section 22 MIL-STD-461 / CS117 FAA AC 20 -136 EUROCAE/ED-14