Fluke 4180

Black Body Calibrator -15C to 120C
-15 °C bis +120 °C Temperaturmessbereich
±0,05 °C Temperaturgenauigkeit
0,10 bis 1,00 (einstellbar) Emissionsgrad
55:1 Optisches Auflösungsverhältnis
8 µm bis 14 µm Spektralbereich
Datenblatt anfordern
Attribut Wert
Temperaturmessbereich -15 °C bis +120 °C
Temperaturgenauigkeit ±0,05 °C
Emissionsgrad 0,10 bis 1,00 (einstellbar)
Optisches Auflösungsverhältnis 55:1
Spektralbereich 8 µm bis 14 µm
Anzahl der Messpunkte 4.800 Pixel (80 × 60)
Bildwiederholrate 9 Hz
Anzeigetyp 3,5-Zoll-LCD-Farbdisplay
Schutzklasse IP54
Stromversorgung Wiederaufladbarer Lithium-Ionen-Akku
Kalibrierungsformular Fluke 4180

Reparaturformular Fluke 4180
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
Model4180

 Fluke 4180 Black Body Calibrator

 

The  Fluke 4180 Black Body Calibrator is a  Precision Infrared calibrator designed for calibrating  infrared thermometers and thermal imagers within a specific temperature range.  It is  is fast, accurate, and easy to use.  Fluke 4180 Black Body Calibrator  comes with an accredited calibration from one of the world's most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making highquality infrared thermometer calibrations.

Fluke 4180 Black Body Calibrator  has a temperature range  temperatures from €“15 °C to 120 °C.  In addition, with accuracies as good as ± 0.35 °C the 4180 can meet its specifications without additional emissivity related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.  Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." Fluke 4180 Black Body Calibrator  can be radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.

 

Specifications for the  Fluke 4180 Black Body Calibrator Include:

Temperature range €“15 °C to 120 °C
Nominal emissivity 0.95
Stability ±0.10 °C at €“15 °C; ±0.05 °C at 0 °C; ±0.10 °C at 120 °C
Heating time 15 min: €“15 °C to 120 °C; 14 min: 23 °C to 120 °C

 