Fluke 700PD2

Dual Pressure Module,+/-1 PSI, +/-6.9kPa
0 bis 200 psi (0 bis 13,8 bar) Druckbereich
Relativdruck (Manometerdruck) Druckart
±0,05 % des Messbereichsendwerts Genauigkeit
1/4 NPT Männlich Ausgangsanschluss
Nicht korrosive Gase und Flüssigkeiten Medienkompatibilität
Datenblatt anfordern
Attribut Wert
Druckbereich 0 bis 200 psi (0 bis 13,8 bar)
Druckart Relativdruck (Manometerdruck)
Genauigkeit ±0,05 % des Messbereichsendwerts
Ausgangsanschluss 1/4 NPT Männlich
Medienkompatibilität Nicht korrosive Gase und Flüssigkeiten
Betriebstemperatur 0 °C bis 50 °C
Lagertemperatur -20 °C bis 70 °C
Elektrischer Anschluss Kompatibel mit Fluke 700-Serie Druckmessmodulen
Gehäusematerial Edelstahl
Zertifizierungen CE-konform
Fluke 700PD2 Options:
  • 700PD2 - FLUKE-700PCK - Pressure Calibration Kit (power supply, interface adapter, cables, and 700PC Pressure Module Calibration software)
  • 700PD2 - FLUKE-700PMP - Hand operated Pressure Pump, provides pressures up to approximately 150 psi (1000 kPa)
Kalibrierungsformular Fluke 700PD2

Reparaturformular Fluke 700PD2
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
Model700PD2

 Fluke 700PD2  Dual Pressure Module

 

The Fluke  700PD2 Dual Pressure Module allows to measure pressure with the Fluke 700 Series Process Calibrators. It displays pressure readings in any of 10 diffe pressure units specified in the calibrator setup.  The pressure module measures positive and negative pressure using an internal microprocessor. It receives operating power from and sends digital information to the calibrator.  Fluke  700PD2 Dual Pressure Module features internal temperature compensation from 0 to 50 Degree Celsius for full-accuracy performance.  The calibrators automatically time-stamp and store all  saved measurements, saving  time, and eliminating errors associated with making manual notations in the field.

Fluke  700PD2 Dual Pressure Module  has two pressure fittings and measures the difference between the applied pressure on the high fitting versus the low fitting. It functions like a gauge module when the low fitting is open. For best results, it is recommended that the module be pressurized to full scale and then vented to zero pressure (atmosphere) prior to zeroing and making measurements. This module can be calibrated locally using the Fluke 700PCK Pressure Calibration Kit, a PC, and a precision pressure source.  Rugged urethane molded case of Fluke  700PD2 Dual Pressure Module protects the module from rough handling and harsh conditions.

 

Specifications for the  Fluke  700PD2 Gauge Pressure Module Include:

Resolution 0.0001 / 0.07
Measurement range 1  psi  / 6900 Pa
Reference Uncertainty (23 ± 3 °C) 0.15
Total Uncertainty 1 year 0.2

 