Hastings

Hastings 6702

Digital High Voltage Phasing Meter, 40kV
Datenblatt anfordern
Hastings 6702 Options:
  • 6702 - 6702-1 - Underground bushing adapters for 35 kV Elastimold, and all 15 and 25 kV bushings
  • 6702 - 6702-2 - DC Hi-Pot Adapter (allows testing of underground cable by rectifying available system voltage)
  • 6702 - 6702-3 - Underground bushing adapter for 35 kV RTE bushings
  • 6702 - 6703 - Extension Resistors (used in pairs; required for systems above 40 kV)
Kalibrierungsformular Hastings 6702

Reparaturformular Hastings 6702
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
Model6702

 HASTINGS 6702  Digital High Voltage Phasing Meter

 

   The Hastings 6702 Digital High Voltage Phasing Meter used for measuring and verifying the presence of voltage in overhead and underground power lines. It works in three modes - AC (alternating current), Hi-Pot (high potential testing, DC (direct current). Built with a durable, extruded aluminum housing to withstand demanding work conditions, this  Hastings  6702 equipped with a coiled, self-retracting cable that extends up to 10 feet for easy use.  Hastings  6702 Digital High Voltage Phasing Meter performs self-testing and battery check upon startup for reliable operation and auto-shuts down after 40 minutes of inactivity to conserve battery life.  

   Hastings  6702 Digital High Voltage Phasing Meter can determine the relative phase of conductors in a power system and also can assits with maintenance and troubleshooting of electrical systems.  Hastings  6702 features a large, digital display with a resolution of 100 volts for precise readings. The meter has a lighted background for clear viewing in low-light environment.  Hastings  6702 Digital High Voltage Phasing Meter features analog bar graph which provides a secondary visual representation of voltage for better understanding. In Hi-Pot mode, the meter displays the peak voltage reached during cable charging process.

 

Specifications for the  HASTINGS 6702 Digital High Voltage Phasing Meter Include:

Line Voltage Mode 0 €“ 40 kV (AC), 0 €“ 4 kV (DC)
Operating Frequency 50 €“ 60 Hz AC, DC
Operating Temperature -40 ºF to 122 ºF
Accuracy 2% of the reading ± 1  (AC),   ± 100 Volts  (DC)

 