Hipotronics 880PL-DC

| Attribut | Wert |
|---|---|
| Ausgangsspannung | bis zu 80 kV DC |
| Ausgangsleistung | bis zu 880 W |
| Stromausgang | bis zu 11 mA DC |
| Spannungsregelung | Kontinuierlich regelbar von 0 bis zur maximalen Ausgangsspannung |
| Messgenauigkeit | ±1 % der Vollskalenablesung |
| Stromversorgung | 115/230 V AC, 50/60 Hz |
| Prüfmodus | Gleichspannungsprüfung (DC Hipot-Test) |
| Schutzfunktionen | Automatische Abschaltung bei Überstrom und Durchschlag |
| Anzeige | Digitale Anzeige für Spannung und Strom |
| Gehäuse / Bauform | Tischgerät, tragbares Gehäuse für den mobilen Einsatz |
Hipotronics 880PL-DC Options:
- 880PL-DC - HHDA13-280 - 120kV rated grounding stick
- 880PL-DC - HH-SAFE - Safety strobe light with magnetic base
- 880PL-DC - HH-FS - Foot operated interlock switch
- 880PL-DC - EXT-WARN - Warranty Extensions to 2 or 3 years
| Model | 880PL-DC |
|---|
HAEFELY / HIPOTRONICS 880PL-DC HIPOT TESTER
The Haefely/Hipotronics 880PL-DC DC Hipot is a modern solution for testing the insulation strength of electrical apparatus. Outfitted with a state-of-the-art digital interface and extensive safety features, the 880PL-DC ensures simplistic operation, accurate results, and operator safety under all circumstances. It measures output voltage, leakage current, insulation resistance (IR), and polarization index (PI). Test parameters such as target voltage, maximum leakage, ramp rate, and dwell time are all easily adjustable with the 880PL-DC hipot tester.
The 880PL-DC Hipot features the most accurate kilovoltmeter readings regardless of load current. Voltage measurements are taken directly at the output of the high voltage transformer, while cur is measured at the return leg to ensure the highest accuracy. Output power is created through a full-wave, voltage multiplier. Safe operation is built in, with interlock, emergency stop, and battery backup for display meters if input power is lost. All models of the Haefely/Hipotronics 880PL-DC hipot testers are self-contained in a rugged and durable enclosure.
Features of the Haefely / Hipotronics 880PL-DC Hipot Tester include:
- DC hipot test up to 40kV or 80kV, 10mA
- Full-wave voltage doubling rectifier
- Recorded test results and data transfer via USB 2.0
- Adjustable test parameters such as target voltage, maximum leakage, ramp rate, and dwell time
- Automatic grounding of power supply and test object when high voltage is turned OFF
- Accurate cur measurement and guard circuit designed to eliminate stray leakage currents