Bench-top 40 W PIM analyser, LTE800 band, single port
LTE800 Frequency Band
TX1 791-796 MHz, TX2 808-821 MHz Transmit (TX)
832-862 MHz Receive (PIM)
1 to 40 W per tone (+30 to +46 dBm), ±0.35 dB Output Power
3rd, 5th, 7th and 9th order IM Orders
Attribute Value
Frequency Band LTE800
Transmit (TX) TX1 791-796 MHz, TX2 808-821 MHz
Receive (PIM) 832-862 MHz
Output Power 1 to 40 W per tone (+30 to +46 dBm), ±0.35 dB
IM Orders 3rd, 5th, 7th and 9th order
Test Ports 1 (reverse PIM)
Control External system controller with Kaelus PIM software
Environmental +10 to +40 °C operating; indoor use
Kaelus iBA-0790C Options:
  • RTF module - Range to Fault module
  • ACE-1000A - Analyzer Calibration Extender for self-calibration
  • Bias-tee - Optional internal DC / AISG bias-tee
Kalibrierungsformular Kaelus iBA-0790C

Reparaturformular Kaelus iBA-0790C
Maximum file size: 40MB

Der Kaelus iBA-0790C ist ein PIM-Analysator für Tisch- und Rackeinbau für das LTE800-Band aus der iBA-Serie mit 40 W. Es handelt sich um das 1-Port-Modell zur Messung rückwärtiger (reflektierter) PIM.

Die Leistung ist von 1 bis 40 W pro Träger einstellbar, gemessen werden Intermodulationsprodukte 3., 5., 7. und 9. Ordnung. In Verbindung mit einem Steuerrechner und der Kaelus-PIM-Software eignet er sich für Produktions- und Labortests von Antennen, Kabeln, Steckverbindern und Filtern und ist mit dem ACE-Selbstkalibrierwerkzeug kompatibel.

Testwall liefert den gebrauchten Kaelus iBA-0790C vollständig geprüft, mit 12 Monaten Garantie und Lieferung in ganz Europa. Eine Kalibrierung kann auf Wunsch vor dem Versand organisiert werden. Bitte kontaktieren Sie uns, wenn Sie eine Kalibrierung oder Reparatur Ihres Kaelus iBA-0790C benötigen.