Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) 8990B

Peak Power Analyzer, 50 MHz - 40 GHz
2 RF, 2 video Kanäle
50 MHz bis 40 GHz Frequenzbereich
-35 bis +20 dBm Leistungsbereich
15 in Farb- TFT touch Anzeige Anzeige
LAN, USB, RS-232 Schnittstellen
Datenblatt anfordern
Attribut Wert
Kanäle 2 RF, 2 video
Frequenzbereich 50 MHz bis 40 GHz
Leistungsbereich -35 bis +20 dBm
Anzeige 15 in Farb- TFT touch Anzeige
Schnittstellen LAN, USB, RS-232
Kompatible Sensoren N1923A, N1924A, N1921A, N1922A, U2000 Serie
Genauigkeit ±0,2 dB (N1923A), ±0,3 dB (N1924A)
Leistungsreferenz intern Sensor check source, 0 dBm bei 50 MHz und 1,05 GHz
Videobandbreite 160 MHz RF Kanäle, 1 GHz video Kanäle
Zeitauflösung 100 MSa/s real Zeit, 1 GSa/s equivalent Zeit; rise Zeit 5 ns max.
Messarten Spitze, Mittelwert, Spitze-bis-Mittelwert, 15 Puls parameters, CCDF
Abmessungen (B × H × T) 430 × 330 × 347 mm
Gewicht 16 kg max.

Kompatible Leistungssensoren

ModellFrequenzbereichLeistungsbereichSensortyp
N1921A50 MHz bis 18 GHz-35 bis +20 dBm (≥500 MHz), -30 bis +20 dBm (50 bis 500 MHz)Spitze und Mittelwert (Diode), Breitband-
N1922A50 MHz bis 40 GHz-35 bis +20 dBm (≥500 MHz), -30 bis +20 dBm (50 bis 500 MHz)Spitze und Mittelwert (Diode), Breitband-
N1923A50 MHz bis 18 GHz-35 bis +20 dBmSpitze und Mittelwert (Diode), Breitband-
N1924A50 MHz bis 40 GHz-35 bis +20 dBmSpitze und Mittelwert (Diode), Breitband-
U2000A10 MHz bis 18 GHz-60 bis +20 dBmUSB Mittelwert Leistung Sensor (Diode)
U2001A10 MHz bis 6 GHz-60 bis +20 dBmUSB Mittelwert Leistung Sensor (Diode)
U2004A9 kHz bis 6 GHz-60 bis +20 dBmUSB Mittelwert Leistung Sensor (Diode)
U2000B10 MHz bis 18 GHz-30 bis +44 dBmUSB Mittelwert Leistung Sensor (Diode)
U2001B10 MHz bis 6 GHz-30 bis +44 dBmUSB Mittelwert Leistung Sensor (Diode)
U2000H10 MHz bis 18 GHz-50 bis +30 dBmUSB Mittelwert Leistung Sensor (Diode)
U2001H10 MHz bis 6 GHz-50 bis +30 dBmUSB Mittelwert Leistung Sensor (Diode)
U2002H50 MHz bis 24 GHz-50 bis +30 dBmUSB Mittelwert Leistung Sensor (Diode)
Keysight (Agilent) 8990B Options:
  • 8990B - 800 - Standard hard drive, installed
  • 8990B - 801 - Removable hard drive, installed
  • 8990B - U01 - With USB host
  • 8990B - U02 - Without USB host
  • 8990B - 1CM - Rackmount kit, 8U full rack
  • 8990B - 1FP - Multi-pulse analysis software, fixed perpetual license
  • 8990B - 1A7 - Compliant calibration test data - ISO17025, printed
  • 8990B - A6J - Certificate of compliance calibration - ANSI/NCSL Z540, printed
  • 8990B - 0BF - English language programming guide, printed
  • 8990B - 0BK - English language user and programming guide, printed
  • 8990B - 0BW - English language service guide, printed
  • 8990B - ABJ - Japanese user guide and English programming guide, printed
  • 8990B - 0B0 - Do not include printed manuals
  • 8990B - ABA - English language user guide, printed
  • N1923A - 105 - Fixed cable option length, 1.5 m (5 ft)
  • N1923A - 106 - Fixed cable option length, 3 m (10 ft)
  • N1924A - 105 - Fixed cable option length, 1.5 m (5 ft)
  • N1924A - 106 - Fixed cable option length, 3 m (10 ft)
Kalibrierungsformular Keysight (Agilent) 8990B

Reparaturformular Keysight (Agilent) 8990B
Maximum file size: 40MB

RENT  KEYSIGHT 8990B (AGILENT) Peak Power Analyzer (call for availability)

The Keysight 8990B (Agilent) Peak Power Analyzer offers faster measurement speed and greater measurement accuracy in key applications such as radar pulse analysis and wireless pulse measurement. Designed with both ease of use and high performance in mind the Agilent 8990B Peak Power Analyzer saves you time and effort allowing you to focus on the important details. When used with a compatible peak power sensor, this analyzer is able to measure the dynamic or time-dependent aspects of RF and microwave power.

Features and Specifications of the Keysight 8990B (Agilent) Peak Power Analyzer include:

  • Provides internal and external trigger functions
  • 20X zooming capability with dual Screen Zoom Window
  • Internal Zeroing and Calibration
  • Touchscreen Capability
  • Frequency Range:   50 MHz to 40 GHz (sensor dependent)
  • Dynamic range:   -35 to +20dBm (CW) and -25 to +20dBm (Pulse)
  • Short System Rise/ Fall time of 5nsec (-20 to +20dBm)
  • 100 MSa/ sec continuous sampling with >1500 readings/ sec
  • Channels are compatible with U2000 Series power sensors connected using the USB hosts
  • Provide 15 Pulse Characterization Measurement
  • Automated pulse delay measurement between channels
  • 4 channels (RF and Video):
    • RF Channels are 1 and 4
      • Frequency Range:   50 MHz to 40 GHz
      • Dynamic Range:   €“35 dBm to +20 dBm
      • Measurement Unit:   linear (Watt) or Log (dBm) selectable
      • Video Bandwidth:   150 MHz
      • Max Pulse Width:   150 MHz
      • Max Pulse Repetition Rate:   10 MHz
      • Input Coupling:   50 O
      • Vertical Scale:  
        • 0.01 dB/div to 100 dB/div in 1-2-5 sequence or any arbitrary scaling, user defined
        • 1 uW/div to 1 kW/div in 1-2-5 sequence or any arbitrary scaling, user defined
      • Offset:   ± 99 dBm with 0.01 dB resolution
    • Video Channels are 2 and 3
      • Video Inputs allow the simultaneous analysis of time-domain control signals
      • Video Bandwidth:   1GHz
      • Input Impedance:  
        • 50 O ± 2.5%,1 MO ± 1% (11 pF typical)
      • Input Coupling:    
        • 1 MO: AC (3.5 Hz), DC
        • 50 O: DC
      • Vertical Scale:
        • 1 MO: 1 mV/div to 5 V/div in 1-2-5 sequence or any arbitrary scaling, user defined
        • 50 O: 1 mV/div to 1 V/div in 1-2-5 sequence or any arbitrary scaling, user defined
      • DC Gain Accuracy:   ± 5% of full scale at full resolution on channel scale ± 5 °C from cal temp
      • Offset Accuracy:   ± (1.25% of channel offset +1% of full scale + 1 mV)
 