Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) PV8932A

Photovoltaic Array Simulator, 2000V, 30A, 30kW
0 V bis 80 V Spannungsbereich
0 A bis 32 A Strombereich
1000 W Maximale Ausgangsleistung
1 Kanal Anzahl der Ausgangskanäle
GPIB, USB, LAN (LXI) Programmierbare Schnittstellen
Datenblatt anfordern
Attribut Wert
Spannungsbereich 0 V bis 80 V
Strombereich 0 A bis 32 A
Maximale Ausgangsleistung 1000 W
Anzahl der Ausgangskanäle 1 Kanal
Programmierbare Schnittstellen GPIB, USB, LAN (LXI)
Spannungseinstellgenauigkeit ±0,05 % + 10 mV
Stromeinstellgenauigkeit ±0,05 % + 10 mA
Betriebstemperaturbereich 0 °C bis 55 °C
Eingangsspannung 100 V – 240 V AC, 50/60 Hz
Schutzfunktionen Überspannungsschutz (OVP), Überstromschutz (OCP), Übertemperaturschutz (OTP)
Keysight (Agilent) PV8932A Options:
  • DG8901A - DG8901A - License for SAS Control Pro, enables automated static and dynamic EN50530 test
  • DG9000A - DG9104A - License to control up to 4 PV simulators in DG9000A software
  • DG9000A - DG9108A - License to control up to 8 PV simulators in DG9000A software
  • DG9000A - DG9112A - License to control up to 12 PV simulators in DG9000A software
Kalibrierungsformular Keysight (Agilent) PV8932A

Reparaturformular Keysight (Agilent) PV8932A
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelPV8932A

 KEYSIGHT PV8932A Photovoltaic Array Simulator  

 

The Keysight PV8932A Photovoltaic Array Simulator enables you to develop, verify and optimize the performance of your inverter maximum power point tracking algorithms. Developing and verifying the performance of inverter maximum power point tracking (MPPT) algorithms is challenging. MPPT algorithms are complex, and under-the-sun testing with a comprehensive set of temperature and irradiance conditions is difficult, expensive and time consuming.  As inverters increase in power, the size of the test array would become unmanageable. As they increase in number of inputs on a single inverter, the complexity of test changes exponentially. The only practical test method is to use a laboratory test solution that can simulate from one to many real-world solar array strings.

The Keysight PV8932A Photovoltaic Array Simulators can simulate the output characteristics of a real-world photovoltaic array. The PV8932A PV array simulator is an autoranging, programmable DC power source that can quickly simulate I-V curve characteristics under diffe environmental conditions (temperature, irradiance, age, cell technology and more), enabling you to quickly and comprehensively test your solar inverters.  The Keysight Technologies PV8900 Series PV array simulator provides up to 30 kW autoranging, single-output programmable DC power. The autoranging output characteristic enable a wide range of voltage and cur combinations at full power.

 

Specifications for the  KEYSIGHT PV8932A Photovoltaic Array Simulator Include:

Max Voltage 2000  V
Max  Current 30  A
Total Power 30 kW

Transient Response

300 µs

 