Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) DSO7104B

1 GHz, 4 Analog Channel Oscilloscope
1 GHz Bandbreite
4 Kanäle Anzahl der Kanäle
4 GSa/s Abtastrate
8 Mpts (Standard), bis zu 16 Mpts (optional) Speichertiefe
350 ps Anstiegszeit
Datenblatt anfordern
Attribut Wert
Bandbreite 1 GHz
Anzahl der Kanäle 4 Kanäle
Abtastrate 4 GSa/s
Speichertiefe 8 Mpts (Standard), bis zu 16 Mpts (optional)
Anstiegszeit 350 ps
Displaygröße 30,7 cm (12,1 Zoll) XGA-Farbdisplay
Eingangsimpedanz 1 MΩ parallel zu 13 pF
Zeitbasisbereich 1 ns/div bis 50 s/div
Vertikale Auflösung 8 Bit
Triggertypen Flanke, Impulsbreite, Muster, CAN, LIN, I²C, SPI, USB (optional erweiterbar)
Keysight (Agilent) DSO7104B Options:
  • DSO7104B - 002 - Alternative standard probe (N2873A instead of default 10073D)
  • DSO7104B - SEC - Secure Environment Mode - Provides compliance with National Industrial Security Program Operating Manual (NISPOM) Chapter 8 requirements (factory-installed option only for new purchase)
  • DSO7104B - A6J - ANSI Z540 compliant calibration
  • DSO7104B - AMS - CAN/LIN automotive triggering and decode (factory-installed)
  • DSO7104B - LSS - I2C/SPI serial decode option (factory-installed)
  • DSO7104B - 232 - RS-232/UART triggering and decode (factory-installed)
  • DSO7104B - SND - I2S Triggering and Decode (factory-installed)
  • DSO7104B - FLX - FlexRay Measurements (factory-installed)
  • DSO7104B - 553 - MIL-STD 1553 Triggering and Decode (factory-installed)
  • DSO7104B - SGM - Segmented memory (factory-installed)
  • DSO7104B - LMT - Mask limit testing (factory-installed)
  • DSO7104B - N2737A - DSO to MSO upgrade for DSO710xB
  • DSO7104B - N5424A - CAN/LIN automotive triggering and decode (user-installed)
  • DSO7104B - N5423A - I2C/SPI serial decode option (user-installed)
  • DSO7104B - N5457A - RS-232/UART triggering and decode (user-installed)
  • DSO7104B - N5468A - I2S Triggering and Decode (user-installed)
  • DSO7104B - N5432C - FlexRay Measurements (user-installed)
  • DSO7104B - N5469A - MIL-STD 1553 Triggering and Decode (user-installed)
  • DSO7104B - N5454A - Segmented memory (user-installed)
  • DSO7104B - N5455A - Mask limit testing (user-installed)
  • DSO7104B - N5406A - FPGA dynamic probe for Xilinx (MSO models only)
  • DSO7104B - N5434A - FPGA dynamic probe for Altera (MSO models only)
  • DSO7104B - B4610A - Offline viewing and analysis of MSO/DSO data on a PC
  • DSO7104B - U1881A - Power measurement and analysis application
  • DSO7104B - E2690B - ASA's Oscilloscope tools
Kalibrierungsformular Keysight (Agilent) DSO7104B

Reparaturformular Keysight (Agilent) DSO7104B
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelDSO7104B

Der Keysight (Agilent) DSO7104B bietet 1 GHz Bandbreite, 4 GSa/s Abtastrate und 4 analoge Kanäle in einem kompakten 6,5”-Gehäuse mit 12,1” XGA-Display. Er bietet 8 Mpts MegaZoom III Speicher und zeigt bis zu 100.000 Wellenformen/Sekunde.

Mit serieller Dekodierung und automatischer Navigation unterstützt er Protokolle wie I2C, SPI, CAN, LIN und MIL-STD 1553. Segmentierter Speicher und Maskentests verbessern die Analyse.

Testwall kann das gebrauchte Keysight (Agilent) DSO7104B liefern, vollständig getestet. Mit fachkundiger Unterstützung und weltweiter Lieferung bietet Testwall leistungsstarke Instrumentierung mit außergewöhnlicher Zuverlässigkeit. Kontaktieren Sie uns für Kalibrierung oder Reparatur des Keysight (Agilent) DSO7104B.

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.