Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) DSO9404A

Oscilloscope, 4 GHz 4 Ch., 20 GSa/s
4 GHz Bandbreite
4 Kanäle Anzahl der Kanäle
20 GSa/s (Echtzeit) Abtastrate
Bis zu 2 Gpts (mit Option) Speichertiefe
8 Bit Vertikale Auflösung
Datenblatt anfordern
Attribut Wert
Bandbreite 4 GHz
Anzahl der Kanäle 4 Kanäle
Abtastrate 20 GSa/s (Echtzeit)
Speichertiefe Bis zu 2 Gpts (mit Option)
Vertikale Auflösung 8 Bit
Anstiegszeit 116 ps
Zeitbasis-Genauigkeit ±2,5 ppm
Eingangswiderstand 50 Ω / 1 MΩ
Displaygröße 12,1 Zoll XGA-Farbdisplay
Schnittstellenanschlüsse USB, LAN (LXI), GPIB (optional)
Keysight (Agilent) DSO9404A Options:
  • DSO9404A - 001 - RS-232/UART triggering and decode
  • DSO9404A - 002 - EZJIT jitter analysis software
  • DSO9404A - 003 - High-speed SDA and clock recovery
  • DSO9404A - 004 - EZJIT Plus jitter analysis software
  • DSO9404A - 005 - USB triggering and decode
  • DSO9404A - 006 - PCI Express 1.1 triggering and decode
  • DSO9404A - 007 - I²C/SPI triggering and decode
  • DSO9404A - 008 - CAN, LIN, and FlexRay triggering and decode
  • DSO9404A - 009 - InfiniiScan
  • DSO9404A - 010 - User-defined function
  • DSO9404A - 012 - InfiniiSim signal equalization
  • DSO9404A - 013 - InfiniiSim basic signal de-embedding
  • DSO9404A - 014 - InfiniiSim advanced signal de-embedding
  • DSO9404A - 015 - Power measurement application software
  • DSO9404A - 016 - Xilinx FPGA dynamic probe
  • DSO9404A - 017 - Altera FPGA dynamic probe
  • DSO9404A - 018 - RS-232, SPI and I2C triggering and decode bundle
  • DSO9404A - 019 - MIPI D-Phy Triggering and decode
  • DSO9404A - 021 - Ethernet compliance
  • DSO9404A - 029 - USB2.0 compliance
  • DSO9404A - 031 - DDR1 and LPDDR compliance
  • DSO9404A - 032 - DDR2 and LPDDR2 compliance
  • DSO9404A - 033 - DDR3 compliance
  • DSO9404A - 035 - MIPI D-Phy compliance
  • DSO9404A - 038 - SATA1 (1.5 GB/s triggering and decode)
  • DSO9404A - 040 - User definable application
  • DSO9404A - 042 - JTAG (IEEE 1149.1) triggering and decode
  • DSO9404A - 043 - USB HSIC compliance test
  • DSO9404A - 045 - DigRF protocol decode
  • DSO9404A - 046 - SVID protocol triggering and decode
  • DSO9404A - 050 - Memory upgrade to 50 Mpts/ch (100 Mpts on 2 ch)
  • DSO9404A - 061 - MATLAB basic
  • DSO9404A - 062 - MATLAB advanced
  • DSO9404A - 064 - eMMC compliance
  • DSO9404A - 065 - BroadR-Reach compliance
  • DSO9404A - 070 - EZJIT Complete jitter analysis software
  • DSO9404A - 073 - MOST compliance
  • DSO9404A - 075 - MIPI RFFE protocol
  • DSO9404A - 100 - Memory upgrade to 100 Mpts/ch (200 Mpts on 2 ch)
  • DSO9404A - 200 - Memory upgrade to 200 Mpts/ch (400 Mpts on 2 ch)
  • DSO9404A - 500 - Memory upgrade to 500 Mpts/ch (1 Gpts on 2 ch)
  • DSO9404A - A6J - ANSI Z540 compliant calibration
  • DSO9404A - 801 - Removable solid state drive
  • DSO9404A - 1CM - 9000 Series oscilloscope rackmount kit (8U)
Kalibrierungsformular Keysight (Agilent) DSO9404A

Reparaturformular Keysight (Agilent) DSO9404A
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelDSO9404A

Der Keysight (Agilent) DSO9404A bietet 4 GHz Bandbreite, 20 GSa/s Abtastrate und 20 Mpts Speicher pro Kanal (erweiterbar auf 1 Gpts), in einem leisen, leichten Gehäuse mit 15” XGA-LCD.

Das Gerät kombiniert Oszilloskop, Logikanalysator und Protokollanalysator mit fortschrittlicher Triggerung und Protokolldekodierung für viele Standards.

Testwall kann den gebrauchten Keysight (Agilent) DSO9404A vollständig getestet liefern. Mit fachkundigem Support und weltweiter Lieferung garantiert Testwall leistungsstarke Geräte mit hoher Zuverlässigkeit und Servicequalität. Kontaktieren Sie uns für Kalibrierung oder Reparatur des Keysight (Agilent) DSO9404A.

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.