Keysight (Agilent) MSO9404A

| Attribut | Wert |
|---|---|
| Bandbreite | 4 GHz |
| Anzahl der analogen Kanäle | 4 |
| Anzahl der digitalen Kanäle | 16 |
| Maximale Abtastrate | 20 GSa/s |
| Speichertiefe | Bis zu 1 Gpunkte (mit Option) |
| Vertikale Auflösung | 8 Bit |
| Anstiegszeit | 116 ps |
| Zeitbasis-Genauigkeit | ±5 ppm |
| Display | 30,5 cm (12,1 Zoll) XGA-Farbdisplay |
| Eingangsimpedanz | 50 Ω / 1 MΩ umschaltbar |
Keysight Technologies MSO9404A Options:
- MSO9404A - 001 - RS-232/UART triggering and decode
- MSO9404A - 002 - EZJIT jitter analysis software
- MSO9404A - 003 - High-speed SDA and clock recovery
- MSO9404A - 004 - EZJIT plus jitter analysis software
- MSO9404A - 005 - USB triggering and decode
- MSO9404A - 006 - PCI Express 1.1 triggering and decode
- MSO9404A - 007 - I²C/SPI triggering and decode
- MSO9404A - 008 - CAN, LIN, and FlexRay triggering and decode
- MSO9404A - 009 - InfiniiScan
- MSO9404A - 010 - User-defined function
- MSO9404A - 012 - InfiniiSim signal equalization
- MSO9404A - 013 - InfiniiSim basic signal de-embedding
- MSO9404A - 014 - InfiniiSim advanced signal de-embedding
- MSO9404A - 015 - Power measurement application software
- MSO9404A - 016 - FPGA dynamic probe application
- MSO9404A - 018 - RS-232, SPI and I²C triggering and decode bundle
- MSO9404A - 019 - MIPI D-PHY triggering and decode
- MSO9404A - 021 - Ethernet compliance
- MSO9404A - 029 - USB 2.0 compliance
- MSO9404A - 031 - DDR1 and LPDDR compliance
- MSO9404A - 032 - DDR2 and LPDDR2 compliance
- MSO9404A - 033 - DDR3 compliance
- MSO9404A - 035 - MIPI D-PHY compliance
- MSO9404A - 038 - SATA1 (1.5 GB/s triggering and decode)
- MSO9404A - 040 - User definable application
- MSO9404A - 042 - JTAG (IEEE 1149.1) triggering and decode
- MSO9404A - 043 - USB HSIC compliance test
- MSO9404A - 045 - DigRF protocol decode
- MSO9404A - 046 - SVID protocol triggering and decode
- MSO9404A - 050 - Memory depth upgrade to 50 Mpts/ch (4-ch) / 100 Mpts/ch (2-ch)
- MSO9404A - 061 - MATLAB basic
- MSO9404A - 062 - MATLAB advanced
- MSO9404A - 064 - eMMC compliance
- MSO9404A - 065 - BroadR-reach compliance
- MSO9404A - 070 - EZJIT complete jitter analysis software
- MSO9404A - 073 - MOST compliance
- MSO9404A - 075 - MIPI RFFE protocol
- MSO9404A - 100 - Memory depth upgrade to 100 Mpts/ch (4-ch) / 200 Mpts/ch (2-ch)
- MSO9404A - 200 - Memory depth upgrade to 200 Mpts/ch (4-ch) / 400 Mpts/ch (2-ch)
- MSO9404A - 500 - Memory depth upgrade to 500 Mpts/ch (4-ch) / 1 Gpts/ch (2-ch)
- MSO9404A - A6J - ANSI Z540 compliant calibration
- MSO9404A - 1CM - 9000 Series oscilloscope rackmount kit (8U)
- MSO9404A - 801 - Removable solid state drive
| Model | MSO9404A |
|---|
Das Keysight (Agilent) MSO9404A Infiniium-Oszilloskop bietet hohe Präzision mit 4 GHz Bandbreite, 20 GSa/s Abtastrate und bis zu 1 Gpts Speicher pro Kanal. Es kombiniert Oszilloskop, 16-Kanal-Logikanalysator und Protokollanalysator für umfassende Signalanalyse. Mit InfiniiScan-Triggerung und Drag-and-Drop-Messungen erhalten Nutzer tiefe Einblicke in das Signalverhalten.
Ideal zum Debuggen komplexer Systeme bietet das MSO9404A segmentierten Speicher für analoge und digitale Kanäle und unterstützt viele Anwendungen wie CAN, USB, SATA. Konnektivitätsoptionen umfassen MATLAB, LabView und LXI.
Testwall kann das gebrauchte Keysight (Agilent) MSO9404A vollständig getestet liefern. Mit Expertenunterstützung und weltweiter Lieferung bietet Testwall leistungsstarke Instrumentierung mit hoher Zuverlässigkeit. Kontaktieren Sie uns für Kalibrierung oder Reparatur des Keysight (Agilent) MSO9404A.