Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N9030B-550

50 GHz PXA Signal Analyzer, 2.4 mm (m)
3 Hz – 50 GHz Frequenzbereich
bis zu 78 dB Anzeigedynamikbereich
-110 dBc/Hz bei 10 kHz Versatz (bei 1 GHz) Phasenrauschen
-163 dBm/Hz (mit Vorverstärker) Durchschnittliches Rauschen (DANL)
± 0,19 dB (typisch) Amplitudengenauigkeit
Datenblatt anfordern
Attribut Wert
Frequenzbereich 3 Hz – 50 GHz
Anzeigedynamikbereich bis zu 78 dB
Phasenrauschen -110 dBc/Hz bei 10 kHz Versatz (bei 1 GHz)
Durchschnittliches Rauschen (DANL) -163 dBm/Hz (mit Vorverstärker)
Amplitudengenauigkeit ± 0,19 dB (typisch)
Eingangsimpedanz 50 Ohm
Maximaler Eingangspegel +30 dBm (1 Watt)
Analysebandbreite (Echtzeit) bis zu 510 MHz
Auflösungsbandbreite (RBW) 1 Hz – 50 MHz
Schnittstellen und Konnektivität LAN (LXI), USB, GPIB (optional)
Keysight Technologies N9030B-550 Options:
  • N9030B-550 - P03 - Preamplifier, 100 kHz to 3.6 GHz
  • N9030B-550 - P08 - Preamplifier, 100 kHz to 8.4 GHz
  • N9030B-550 - P13 - Preamplifier, 100 kHz to 13.6 GHz
  • N9030B-550 - P26 - Preamplifier, 100 kHz to 26.5 GHz
  • N9030B-550 - P50 - Preamplifier, 100 kHz to 50 GHz
  • N9030B-550 - EA3 - Electronic attenuator up to 3.6 GHz; add in addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB
  • N9030B-550 - B40 - 40 MHz analysis bandwidth; extends the analysis bandwidth from 25 to 40 MHz (Option MPB required for measurements > 3.6 GHz)
  • N9030B-550 - B85 - 85 MHz analysis bandwidth; extends the analysis bandwidth from 25 to 85 MHz (Option MPB required for measurements > 3.6 GHz)
  • N9030B-550 - B1X - 160 MHz analysis bandwidth; extends analysis bandwidth from 25 to 160 MHz (Option MPB required for measurements > 3.6 GHz)
  • N9030B-550 - MPB - Microwave preselector bypass; bypass the microwave preselector for wider bandwidth IF
  • N9030B-550 - LNP - Low noise path; improves sensitivity (DANL) in frequency bands above 3.6 GHz
  • N9030B-550 - EXM - External mixing; provides external mixing with Keysight and third party mixers; single port for LO out and IF in (SMA female)
  • N9030B-550 - FP2 - Fast power; accelerates power measurements such as ACPR; requires Option B40, B85, B1X, B2X, or B5X
  • N9030B-550 - RT1 - Real-time analysis up to maximum available BW, basic detection; includes frequency mask trigger; minimum 17.3 µs signal duration for 100% POI; requires bandwidth Option B85, B1X, B2X, or B5X
  • N9030B-550 - RT2 - Real-time analysis up to maximum available BW, optimum detection; includes frequency mask trigger; minimum 3.57 µs signal duration for 100% POI; requires bandwidth Option B85, B1X, B2X, or B5X
  • N9030B-550 - RTR - Real-time spectrum recorder and analyzer application; enables recording, analyzing and playback of spectrum density data; requires Option RT1 or RT2
  • N9030B-550 - RTS - Real-time I/Q data streaming; stream gap-free 16 bit I/Q data up to 255 MHz bandwidth for offline analysis; requires N9030B-RT1 or N9030B-RT2
  • N9030B-550 - FT1 - Frequency mask trigger, basic detection; enables frequency mask triggering with N9067C pulse application and 89600 VSA software to detect signals as short as 15 µs duration
  • N9030B-550 - FT2 - Frequency mask trigger, optimum detection; enables frequency mask triggering with N9067C pulse application and 89600 VSA software to detect signals as short as 3.6 µs duration
  • N9030B-550 - EMC - Basic EMI precompliance; perform EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths
  • N9030B-550 - EDP - Enhanced display package; includes spectrogram, trace zoom, and zone span
  • N9030B-550 - ESC - External source control for Keysight EXG, MXG, and PSG signal generators; supports external mixing; includes 3 BNC cables and 1 crossover LAN cable
  • N9030B-550 - SSD - Additional removable solid-state drive (SSD); provides a fully-imaged, removable SSD in addition to the one installed in instruments
  • N9030B-550 - SF1 - Exclude launch program; prevents the launching of Windows programs from the instrument application
  • N9030B-550 - SF2 - Prohibit saving results; prevents instrument application from saving/recall of measurement results or user configurations to/from instrument's data storage
  • N9030B-550 - CR3 - Second IF output; wideband IF out; center frequency depends on IF path; output on Aux IF connector at rear panel
  • N9030B-550 - CRP - Arbitrary IF out; IF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel
  • N9030B-550 - YAV - Y-axis video out; screen video (0-1 volt open circuit); log video and linear video
  • N9030B-550 - ALV - Aux log video out; fast rise time video out; output on Aux IF connector
  • N9030B-550 - UK6 - Commercial calibration certificate with test data
  • N9030B-550 - AMG - Keysight Calibration + Uncertainties + Guardbanding (accredited cal); provides ISO 17025A accredited calibration from factory
  • N9030B-550 - A6J - ANSI Z540-1-1994 Calibration; provides ANSI Z540 compliant calibration from factory
Kalibrierungsformular Keysight (Agilent) N9030B-550

Reparaturformular Keysight (Agilent) N9030B-550
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelN9030B-550

Der Keysight (Agilent) N9030B-550 ist ideal für mmWave- und 5G-Forschung und -Entwicklung und bietet einen Frequenzbereich von 3 Hz bis 50 GHz sowie bis zu 1 GHz Echtzeitbandbreite (optional). Er überzeugt durch geringes DANL, hervorragendes Rauschmaß, Unterstützung schneller digitaler Modulation und Funktionen wie Preselector-Bypass, Zeitgating und digitale Demodulation.

Ein ausgezeichneter Spektrumanalysator für fortgeschrittene Signalanalyse und automatisierte Tests in Entwicklungsumgebungen.

Testwall kann den gebrauchten Keysight (Agilent) N9030B-550 liefern, vollständig getestet. Mit fachkundiger Unterstützung und weltweitem Versand bietet Testwall leistungsstarke Messtechnik mit unvergleichlicher Zuverlässigkeit und Servicequalität. Bitte kontaktieren Sie uns direkt, wenn Sie eine Kalibrierung oder Reparatur des Keysight (Agilent) N9030B-550 benötigen.

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.