Manufacturer Logo

Rohde & Schwarz ESR7

HerstellerRohde & Schwarz
ModellESR7
ProduktEMI Test Receiver, 9 kHz to 7 GHz
TypGebraucht

 

Rohde & Schwarz ESI26

Rohde & Schwarz ESI26

Rohde & Schwarz ESW26

Rohde & Schwarz ESW26

Holen Sie sich ein Angebot
SKU
twESR7

RENT R&S ESR7 (call for availability)

The R&S ESR7 EMI Test Receiver is a dual instrument that measures electromagnetic disturbances while simultaneously functioning as a fully featured, powerful signal and spectrum analyzer for lab applications.   Rapid-fire-speed measuring occurs by the instrument's use of an FFT-based time domain scan and detailed analysis and history of disturbance signals is accomplished by realtime spectrum analysis using a wide variety of diagnostic tools. This robust and compact, dual instrument is user friendly with its straightforward display, intuitive touchscreen interface.

Features and Specifications of the R&S ESR7 EMI Test Receiver include:

  • Features
    • EMI test receiver and signal/spectrum analyzer combined in a single instrument
    • Compliant with CISPR 16-1-1 Ed. 3.1
    • Preselection with integrated 20 dB preamplifier
    • Ultra-fast time domain scan in addition to conventional stepped frequency scan
    • Realtime spectrum analysis with up to 40  MHz span for detailed investigation of disturbance signals
    • Powerful measurement and analysis functions in frequency and time domain
    • Time domain display with high resolution (50  Î¼s)
    • Automatic test routines
    • Convenient operation, straightforward display
    • Robust and compact - ideal for the mobile use
  • Specifications
    • Frequency
      • Frequency Range:   9  kHz to  7 GHz
    • Level
      • Max RF level (CW):
        • RF attenuation ‰¥ 10 dB; RF preamplifier off:   30 dBm (= 1 W)
        • RF attenuation ‰¥ 10 dB; RF preamplifier on:   23 dBm (= 0.2 W)
      • Max Pulse Voltage:
        • RF attenuation ‰¥ 10 dB:
          • Input 1:   150 V
          • Input 2:   450 V
      • Max Pulse Energy:
        • RF attenuation ‰¥ 10 dB; 10 μs
          • Input 1:   1 mWs
          • Input 2:     20 mWs
      • 1 dB Compression:
        • RF attenuation 0 dB; RF preamplifier and preselection off:   +3 dBm, nominal
    • IF and Resolution Bandwiths
      • Analyzer Mode (span ‰¥ 10 Hz) and Receiver Mode: 10 Hz to10 MHz ( €“3 dB) in 1/2/3/5/10 steps
      • Analyzer and Receiver Mode: 200 Hz, 9 kHz, 120 kHz ( €“6 dB), 1 MHz (impulse bandwidth)
      • Preselection:
        • Can be switched off in analyzer mode:   16 Fixed Filters
      • Preamplifier:
        • Can be switched on/off:   1 kHz to 7 GHz, 20 dB gain, nominal
      • Measurement Time:
        • Analyzer Mode (Sweep Time):
          • span = 0  Hz: 1  Î¼s to 16  000  s
          • span ‰¥ 10  Hz (swept): 1  ms to 16  000  s
          • span ‰¥ 10  Hz (FFT): 7  Î¼s to 16  000  s
        • Receiver Mode (Stepped Frequency Scan):   50 μs to 100 s (per frequency)
        • Receiver Mode (Time Domain Scan):   50 μs to 100 s (per frequency subrange)
      • Frequency Step Size:
        • Receiver Mode (Stepped Frequency Scan):   min. 1 Hz
        • Receiver Mode (Time Domain Scan):   0.25 × IF bandwidth
    • Detectors
      • Receiver Mode:
        • maximum peak
        • minimum peak
        • quasi-peak
        • RMS
        • average
        • average with meter time constant (CISPR average)
        • RMS average (CISPR-RMS)
    • Displayed Average Noise Level (DANL)
      • Receiver Mode, Nominal, Average Detector (AV), RF Attenuation 0 dB, Termination 50 Ω:
        • Preamplifier Off:
          • 500 MHz, bandwidth 120 kHz:   < 6 dBμV
          • 3 GHz, bandwidth 1 MHz:   < 17 dBμV
        • Preamplifier On:
          • 500 MHz, bandwidth 120 kHz:   < €“7 dBμV
          • 3 GHz, bandwidth 1 MHz:   < 5 dBμV
    • Number of Sweep (Trace) Points
      • Analyzer Mode (Standard):   101 to 32 001
      • Analyzer Mode (EMI):   101 to 200 001
      • Receiver Mode:   Max 4 000 000
      • Realtime Analyzer (Option):   801
    • Total Measurement Uncertainty
      • CW signal, level 0 dB to €“70 dB below reference level, S/N > 20 dB, auto  sweep  time,                       RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, preselection on,                                                                                                        
        span/RBW<100, 95% confidence level, +200C to +300C
        • 9 kHz ‰¤ f < 3.6 GHz:   0.46 dB
        •  3.6 GHz ‰¤ f ‰¤ 7 GHz:   0.57 dB

 

Keine verwandten Beiträge

Rückgaben

Wenn Sie mit Ihrem Kauf nicht vollständig zufrieden sind, senden Sie den Artikel einfach innerhalb von 30 Tagen nach Erhalt in seinem Originalzustand an uns zurück. Zurückgesandte Artikel müssen unbenutzt sein und in der Originalverpackung mit allen beigefügten Unterlagen zurückgeschickt werden. Nach Erhalt erstatten wir Ihnen den vollen Betrag, abzüglich der ursprünglichen Lieferkosten. Alternativ tauschen wir den Artikel gerne um, wenn Sie dies bevorzugen.