Rohde & Schwarz
Rohde & Schwarz ESU8
EMI Receiver 20Hz-8GHz
20 Hz – 8 GHz Frequenzbereich
EMI-Testempfänger Messempfänger-Typ
10 Hz, 100 Hz, 200 Hz, 1 kHz, 9 kHz, 10 kHz, 100 kHz, 120 kHz, 1 MHz Zwischenfrequenzbandbreiten (6-dB)
Spitzenwert, Quasispitzenwert, Mittelwert, RMS, CISPR-Mittelwert Detektoren
50 Ω Eingangsimpedanz

| Attribut | Wert |
|---|---|
| Frequenzbereich | 20 Hz – 8 GHz |
| Messempfänger-Typ | EMI-Testempfänger |
| Zwischenfrequenzbandbreiten (6-dB) | 10 Hz, 100 Hz, 200 Hz, 1 kHz, 9 kHz, 10 kHz, 100 kHz, 120 kHz, 1 MHz |
| Detektoren | Spitzenwert, Quasispitzenwert, Mittelwert, RMS, CISPR-Mittelwert |
| Eingangsimpedanz | 50 Ω |
| Messbereich (Pegelbereich) | -7 dBμV bis 137 dBμV |
| Eigenrauschen (typisch) | -148 dBm bei 1 GHz (mit Vorverstärker) |
| Normenkonformität | CISPR 16-1-1, MIL-STD-461, FCC, VDE |
| Schnittstellen | GPIB (IEEE 488), LAN (Ethernet), USB |
| Anzeigedynamik | 100 dB |
Rohde & Schwarz ESU8 Options:
- ESU8 - R&S FSU-B4 - OCXO, low aging / improved phase noise at 10 Hz carrier offset
- ESU8 - R&S FSU-B9 - Tracking Generator, 100 kHz to 3.6 GHz
- ESU8 - R&S FSP-B10 - External Generator Control
- ESU8 - R&S FSU-B12 - Output Attenuator, 0 dB to 70 dB, for R&S FSU-B9 (requires R&S FSU-B9)
- ESU8 - R&S ESU-B18 - Removable Hard Disk
- ESU8 - R&S ESU-B19 - Second Hard Disk for R&S ESU-B18 (requires R&S ESU-B18)
- ESU8 - R&S ESU-B24 - Low-Noise Preamplifier (100 kHz to 8 GHz)
- ESU8 - R&S ESU-K53 - Time Domain Scan (key code)
- ESU8 - R&S ESPIK50 - Triggered Scan for Coverage Measurements (key code)
| Model | ESU8 |
|---|
Key Facts
* Combination of CISPR 16-compliant EMI test receiver and high-end spectrum analyzer
* High speed time domain scan (FFT) option
* All commercial and military standards met
* Internal preselection (can be switched off in analyzer mode)
* Integrated 20 dB preamplifier up to 3.6 GHz as standard
* Receiver mode with parallel IF analysis
* Frequency scan with max. three detectors in parallel (max. 2 million test points/trace)
* Second RF input (max. 1 GHz, pulse-protected)
* Time-domain analysis for evaluation of timing behavior of disturbances (e.g. click-rate analysis)
* Fast and reliable measurements using automatic and interactive test routines
* Integrated report generator
* Optional low-noise preamplifiers up to 8 GHz (R&S ESU-B24)