Sorensen SGA75-266

HerstellerSorensen
ModellSGA75-266
ProduktDC Power Supply, 75V, 266A, 20kW
TypGebraucht

 

Sorensen SGA60-500

Sorensen SGA60-500

Sorensen SGA80/125

Sorensen SGA80/125

Holen Sie sich ein Angebot
SKU
138810
SORENSEN SGA75-266 DC Power Supply (call for availability)

The Sorensen SGA75-266 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.

The Sorensen 
SGA75-266 DC Power Supply (SGA = Sorensen General Purpose Analog), with its high performance power electronics, meets the need for simple front panel analog controls or external control. It provides essential features like 10-turn potentiometers for setting voltage and cur, 3 ½ digit LED readout, plus front panel over-voltage protection (OVP) preview/adjustment and reset.

Features and Specifications of the Sorensen
SGA75-266 DC Power Supply include:
  • High Power Density: Up to 20 kW
  • Wide Voltage Range: 0-75V up to 0-266V, in increments of 3 kW from 5 to 20 kW
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise:  Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • 16-bit Resolution:  Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Common:
  • Remote Sense:  Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply).
  • Parallel Operation:  Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
  • Series Operation:  Up to 2 units
  • Input:
  • Nominal Voltage 3 phase, 3 wire + ground
      • 208/220 VAC (operating range 187 - 242 VAC)
      • 380/400 VAC (operating range 342 - 440 VAC)
      • 440/480 VAC (operating range 396 - 528 VAC)
  • Frequency:  47 – 63Hz , 400Hz
  • Power Factor
      • >0.9 typical for 208/220 VAC input (10V - 800V)
      • >0.78 typical for 380/400 VAC input (40V - 800V)
      • >0.9 typical for 380/480 VAC input (10V - 30V)
      • >0.7 typical for 440/480 VAC input (40V - 800V)
      • >0.9 typical for 440/480 VAC input (10V - 30V)
  • Protection:  ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
    • 208/220 VAC (operating range 187 - 242 VAC)
    • 380/400 VAC (operating range 342 - 440 VAC)
    • 440/480 VAC (operating range 396 - 528 VAC)
  • 208/220 VAC (operating range 187 - 242 VAC)
  • 380/400 VAC (operating range 342 - 440 VAC)
  • 440/480 VAC (operating range 396 - 528 VAC)
    • >0.9 typical for 208/220 VAC input (10V - 800V)
    • >0.78 typical for 380/400 VAC input (40V - 800V)
    • >0.9 typical for 380/480 VAC input (10V - 30V)
    • >0.7 typical for 440/480 VAC input (40V - 800V)
    • >0.9 typical for 440/480 VAC input (10V - 30V)
  • >0.9 typical for 208/220 VAC input (10V - 800V)
  • >0.78 typical for 380/400 VAC input (40V - 800V)
  • >0.9 typical for 380/480 VAC input (10V - 30V)
  • >0.7 typical for 440/480 VAC input (40V - 800V)
  • >0.9 typical for 440/480 VAC input (10V - 30V)
  • Output:
  • Voltage and Cur Range: 75V, 266A, 20kW
  • Ripple & Noise:
      • rms(20Hz-300kHz): 80mV
      • p-p: 500mV
    • rms(20Hz-300kHz): 80mV
    • p-p: 500mV
  • rms(20Hz-300kHz): 80mV
  • p-p: 500mV
  • Programming & Read-Back Specifications:
  • Front Panel Display:
    • Programming:
      • Accuracy: +/- (0.5%fs + 1 digit)
      • Resolution: 3.5 digits
    • Read-Back Monitoring:
      • Accuracy: +/- (0.5%fs + 1 digit)
      • Resolution: 3.5 digits
    • Knob control & Display read-back
  • Remote Analog Interface
    • Programming:
      • Accuracy:
        • Voltage: +/-0.25% of full scale
        • Cur: 0.8% of full scale 
    • Read-Back Monitoring:
      • Accuracy: +/-1.0% of full scale
    • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Remote Digital Interface:
    • Programming:
      • Accuracy:
        • Voltage:  +/- 0.1% of full scale
        • Cur: +/- 0.4% of full scale
      • Resolution: +/-0.002% of full scale
    • Read-Back Monitoring:
      • Accuracy:
        • Voltage:  +/- 0.15% of full scale
        • Cur:  +/- 0.4% of full scale
      • Resolution:  +/-0.002% of full scale
    • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • OVP:
    • Programming:
      • Accuracy: +/- 1% of full scale
      • Resolution: +/-0.002% of full scale
    • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • User I/O:
    • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Programming:
    • Accuracy: +/- (0.5%fs + 1 digit)
    • Resolution: 3.5 digits
  • Read-Back Monitoring:
    • Accuracy: +/- (0.5%fs + 1 digit)
    • Resolution: 3.5 digits
  • Knob control & Display read-back
  • Accuracy: +/- (0.5%fs + 1 digit)
  • Resolution: 3.5 digits
  • Accuracy: +/- (0.5%fs + 1 digit)
  • Resolution: 3.5 digits
  • Programming:
    • Accuracy:
      • Voltage: +/-0.25% of full scale
      • Cur: 0.8% of full scale 
  • Read-Back Monitoring:
    • Accuracy: +/-1.0% of full scale
  • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Accuracy:
    • Voltage: +/-0.25% of full scale
    • Cur: 0.8% of full scale 
  • Voltage: +/-0.25% of full scale
  • Cur: 0.8% of full scale 
  • Accuracy: +/-1.0% of full scale
  • Programming:
    • Accuracy:
      • Voltage:  +/- 0.1% of full scale
      • Cur: +/- 0.4% of full scale
    • Resolution: +/-0.002% of full scale
  • Read-Back Monitoring:
    • Accuracy:
      • Voltage:  +/- 0.15% of full scale
      • Cur:  +/- 0.4% of full scale
    • Resolution:  +/-0.002% of full scale
  • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • Accuracy:
    • Voltage:  +/- 0.1% of full scale
    • Cur: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • Voltage:  +/- 0.1% of full scale
  • Cur: +/- 0.4% of full scale
  • Accuracy:
    • Voltage:  +/- 0.15% of full scale
    • Cur:  +/- 0.4% of full scale
  • Resolution:  +/-0.002% of full scale
  • Voltage:  +/- 0.15% of full scale
  • Cur:  +/- 0.4% of full scale
  • Programming:
    • Accuracy: +/- 1% of full scale
    • Resolution: +/-0.002% of full scale
  • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •     

    Keine verwandten Beiträge

    Rückgaben

    Wenn Sie mit Ihrem Kauf nicht vollständig zufrieden sind, senden Sie den Artikel einfach innerhalb von 30 Tagen nach Erhalt in seinem Originalzustand an uns zurück. Zurückgesandte Artikel müssen unbenutzt sein und in der Originalverpackung mit allen beigefügten Unterlagen zurückgeschickt werden. Nach Erhalt erstatten wir Ihnen den vollen Betrag, abzüglich der ursprünglichen Lieferkosten. Alternativ tauschen wir den Artikel gerne um, wenn Sie dies bevorzugen.