Tektronix DPO5034

| Attribut | Wert |
|---|---|
| Anzahl der Kanäle | 4 Kanäle |
| Bandbreite | 350 MHz |
| Abtastrate | 5 GS/s (auf allen Kanälen) |
| Aufzeichnungslänge | 25 M Punkte (Standard) |
| Vertikale Auflösung | 8 Bit |
| Eingangsimpedanz | 1 MΩ oder 50 Ω |
| Zeitbasisbereich | 200 ps/div bis 1000 s/div |
| Triggertypen | Flanke, Impulsbreite, Logik, Setup/Hold, Anstiegszeit, Runt, Sequenz, Video |
| Anzeige | 10,4-Zoll-Farb-LCD-Display (SVGA, 800 × 600) |
| Schnittstellen | USB, LAN (LXI), GPIB (optional), Compact Flash |
Tektronix DPO5034 Options:
- DPO5034 - 2RL - 25 M/Ch record length
- DPO5034 - 5RL - 50 M/Ch record length
- DPO5034 - 10RL - 125 M/Ch record length
- DPO5034 - SSD - Solid state hard disk drive, ≥300 GB
- DPO5034 - DDRA - DDR Memory bus analysis (Requires Opt. DJA) (Available on 1 GHz and 2 GHz models only.)
- DPO5034 - DJA - Jitter and Eye Analysis Tools – Advanced (DPOJET)
- DPO5034 - ET3 - Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
- DPO5034 - HSIC - USB HSIC protocol decode and electrical validation (Available on 2 GHz models only.)
- DPO5034 - LT - Waveform limit testing
- DPO5034 - MOST - MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)
- DPO5034 - MTM - Mask testing
- DPO5034 - PWR - Power measurement and analysis
- DPO5034 - SR-AERO - Aerospace serial triggering and analysis (MIL-STD-1553)
- DPO5034 - SR-AUTO - Automotive serial triggering and analysis (CAN/LIN/FlexRay)
- DPO5034 - SR-COMP - Computer serial triggering and analysis (RS-232/422/485/UART)
- DPO5034 - SR-DPHY - MIPI® D-PHY serial analysis
- DPO5034 - SR-EMBD - Embedded serial triggering and analysis (I2C, SPI)
- DPO5034 - SR-ENET - Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)
- DPO5034 - SR-PCIE - PCI Express serial analysis (Available on ≥1 GHz models only.)
- DPO5034 - SR-USB - USB 2.0 serial triggering and analysis (LS, FS, HS)
- DPO5034 - SR-810B - 8b/10b serial analysis
- DPO5034 - SVA - SignalVu® AM/FM/PM/Direct audio measurements (Requires Opt. SVE)
- DPO5034 - SVE - SignalVu® Essentials – Vector signal analysis software
- DPO5034 - SVM - SignalVu® General purpose modulation analysis (Requires Opt. SVE)
- DPO5034 - SVP - SignalVu® Pulse – Advanced signal analysis (Requires Opt. SVE)
- DPO5034 - SVT - SignalVu® Settling time measurements – frequency and phase (Requires Opt. SVE)
- DPO5034 - USB - USB 2.0 Compliance testing (Requires TDSUSBF (USB Test Fixture). 2 GHz bandwidth required for high-speed USB)
- DPO5034 - USBPWR - Automated compliance test solution for USB power adapters
- DPO5034 - VET - Visual Trigger and Search
- DPO5034 - VNM - CAN/LIN Protocol analysis software
- DPO5034 - PS1 - Power Solution Bundle: DPOPWR, P5205A, TCP0030A, TPA-BNC, 067-1686-xx (Deskew fixture), 119-7465-xx (external probe power supply)
- DPO5034 - PS2 - Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)
- DPO5034 - PS3 - Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)
- DPO5034 - A0 - North America power plug (115 V, 60 Hz)
- DPO5034 - A1 - Universal Euro power plug (220 V, 50 Hz)
- DPO5034 - A2 - United Kingdom power plug (240 V, 50 Hz)
- DPO5034 - A3 - Australia power plug (240 V, 50 Hz)
- DPO5034 - A5 - Switzerland power plug (220 V, 50 Hz)
- DPO5034 - A6 - Japan power plug (100 V, 110/120 V, 60 Hz)
- DPO5034 - A10 - China power plug (50 Hz)
- DPO5034 - A11 - India power plug (50 Hz)
- DPO5034 - A12 - Brazil power plug (60 Hz)
- DPO5034 - A99 - No power cord
- DPO5034 - L0 - English manual
- DPO5034 - L1 - French manual
- DPO5034 - L3 - German manual
- DPO5034 - L5 - Japanese manual
- DPO5034 - L7 - Simplified Chinese manual
- DPO5034 - L8 - Traditional Chinese manual
- DPO5034 - L9 - Korean manual
- DPO5034 - L10 - Russian manual
- DPO5034 - L99 - No manual
- DPO5034 - C3 - Calibration Service 3 Years
- DPO5034 - C5 - Calibration Service 5 Years
- DPO5034 - D1 - Calibration Data Report
- DPO5034 - D3 - Calibration Data Report 3 Years (with Opt. C3)
- DPO5034 - D5 - Calibration Data Report 5 Years (with Opt. C5)
- DPO5034 - G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - G5 - Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- DPO5034 - R3 - Repair Service 3 Years (including warranty)
- DPO5034 - R5 - Repair Service 5 Years (including warranty)
| Model | DPO5034 |
|---|
Der Tektronix DPO5034 bietet 4 analoge Kanäle mit 350 MHz Bandbreite und bis zu 5 GS/s Abtastrate (10 GS/s auf ein oder zwei Kanälen) sowie eine Standard-Aufzeichnungslänge von 12,5 M. FastAcq® erreicht über 250 000 Wellenformen/s, und FastFrame™ ermöglicht segmentierte Erfassung bis zu 290 000 Segmente und über 310 000 Wellenformen/s—ideal für schnelle Signalerfassung.
Mit Wave Inspector® Oberfläche, 53 automatisierten Messungen, FFT, Histogrammen, Augen- und Jitteranalyse, optionaler Protokoll-Triggerung und einem 10,4″ XGA-Touchscreen ist es ideal für detaillierte Signaluntersuchungen.
Testwall kann das gebrauchte Tektronix DPO5034 vollständig getestet liefern. Mit fachkundigem Support und weltweitem Versand bietet Testwall leistungsstarke Messtechnik mit höchster Zuverlässigkeit und Servicequalität. Kontaktieren Sie uns für Kalibrierung oder Reparatur des Tektronix DPO5034.