Tektronix
Tektronix DPO5054
Digital Phosphor Oscilloscope, 500 MHz 4 Ch., 5 GS/s
500 MHz Bandbreite
4 Anzahl der Kanäle
5 GS/s Abtastrate
25 Megapunkte pro Kanal Aufzeichnungslänge
8 Bit Vertikale Auflösung

| Attribut | Wert |
|---|---|
| Bandbreite | 500 MHz |
| Anzahl der Kanäle | 4 |
| Abtastrate | 5 GS/s |
| Aufzeichnungslänge | 25 Megapunkte pro Kanal |
| Vertikale Auflösung | 8 Bit |
| Eingangsimpedanz | 1 MΩ oder 50 Ω |
| Zeitbasisbereich | 200 ps/div bis 1000 s/div |
| Anzeigetyp | 10,4 Zoll TFT-Farb-LCD |
| Schnittstellenanschlüsse | USB, LAN (LXI), VGA |
| Triggertypen | Flanke, Impulsbreite, Logik, Setup/Hold, Anstiegszeit, Runt, Sequenz |
Tektronix DPO5054 Options:
- DPO5054 - 2RL - Record length upgrade: 25 M/Ch
- DPO5054 - 5RL - Record length upgrade: 50 M/Ch
- DPO5054 - 10RL - Record length upgrade: 125 M/Ch
- DPO5054 - SSD - Solid state hard disk drive, ≥300 GB
- DPO5054 - DJA - Jitter and Eye Analysis Tools – Advanced (DPOJET)
- DPO5054 - ET3 - Ethernet compliance test (Requires TF-GBE-BTP or TF-GBE-ATP Ethernet Test Fixture)
- DPO5054 - LT - Waveform limit testing
- DPO5054 - MOST - MOST Essentials – Electrical compliance and debug test solution for MOST50 and MOST150 (Requires Opt. DJA)
- DPO5054 - MTM - Mask testing
- DPO5054 - PWR - Power measurement and analysis
- DPO5054 - SR-AERO - Aerospace serial triggering and analysis (MIL-STD-1553)
- DPO5054 - SR-AUTO - Automotive serial triggering and analysis (CAN/LIN/FlexRay)
- DPO5054 - SR-COMP - Computer serial triggering and analysis (RS-232/422/485/UART)
- DPO5054 - SR-DPHY - MIPI D-PHY serial analysis
- DPO5054 - SR-EMBD - Embedded serial triggering and analysis (I2C, SPI)
- DPO5054 - SR-ENET - Ethernet serial triggering and analysis (10BASE-T, 100BASE-TX)
- DPO5054 - SR-USB - USB 2.0 serial triggering and analysis (LS, FS, HS)
- DPO5054 - SR-810B - 8b/10b serial analysis
- DPO5054 - SVA - SignalVu AM/FM/PM/Direct audio measurements (Requires Opt. SVE)
- DPO5054 - SVE - SignalVu Essentials – Vector signal analysis software
- DPO5054 - SVM - SignalVu General purpose modulation analysis (Requires Opt. SVE)
- DPO5054 - SVP - SignalVu Pulse – Advanced signal analysis (Requires Opt. SVE)
- DPO5054 - SVT - SignalVu Settling time measurements – frequency and phase (Requires Opt. SVE)
- DPO5054 - USB - USB 2.0 Compliance testing (Requires TDSUSBF USB Test Fixture)
- DPO5054 - USBPWR - Automated compliance test solution for USB power adapters
- DPO5054 - VET - Visual Trigger and Search
- DPO5054 - VNM - CAN/LIN Protocol analysis software
- DPO5054 - PS1 - Power Solution Bundle: DPOPWR, P5205A, TCP0030A, TPA-BNC, 067-1686-xx (Deskew fixture), 119-7465-xx (external probe power supply)
- DPO5054 - PS2 - Power Solution Bundle: DPOPWR, THDP0200, TCP0030A, 067-1686-xx (Deskew fixture)
- DPO5054 - PS3 - Power Solution Bundle: DPOPWR, TMDP0200, TCP0020, 067-1686-xx (Deskew fixture)
- DPO5054 - A0 - North America power plug (115 V, 60 Hz)
- DPO5054 - A1 - Universal Euro power plug (220 V, 50 Hz)
- DPO5054 - A2 - United Kingdom power plug (240 V, 50 Hz)
- DPO5054 - A3 - Australia power plug (240 V, 50 Hz)
- DPO5054 - A5 - Switzerland power plug (220 V, 50 Hz)
- DPO5054 - A6 - Japan power plug (100 V, 110/120 V, 60 Hz)
- DPO5054 - A10 - China power plug (50 Hz)
- DPO5054 - A11 - India power plug (50 Hz)
- DPO5054 - A12 - Brazil power plug (60 Hz)
- DPO5054 - A99 - No power cord
- DPO5054 - L0 - English manual
- DPO5054 - L1 - French manual
- DPO5054 - L3 - German manual
- DPO5054 - L5 - Japanese manual
- DPO5054 - L7 - Simplified Chinese manual
- DPO5054 - L8 - Traditional Chinese manual
- DPO5054 - L9 - Korean manual
- DPO5054 - L10 - Russian manual
- DPO5054 - L99 - No manual
- DPO5054 - C3 - Calibration Service 3 Years
- DPO5054 - C5 - Calibration Service 5 Years
- DPO5054 - D1 - Calibration Data Report
- DPO5054 - D3 - Calibration Data Report 3 Years (with Opt. C3)
- DPO5054 - D5 - Calibration Data Report 5 Years (with Opt. C5)
- DPO5054 - G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- DPO5054 - G5 - Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- DPO5054 - R3 - Repair Service 3 Years (including warranty)
- DPO5054 - R5 - Repair Service 5 Years (including warranty)
| Model | DPO5054 |
|---|
Das digitale Phosphoroszilloskop Tektronix DPO5054 bietet 500 MHz Bandbreite, 4 analoge Kanäle und eine Abtastrate von 5 GS/s. Mit Wave Inspector®, FFT-Analyse und bis zu 125M Speicherpunkten erleichtert es komplexes Debugging. Unterstützt TekVPI®-Tastköpfe und serielle Protokolle wie CAN, LIN, I2C und USB.
Ideal für Ingenieure bei der Analyse gemischter Signale, mit 10,4"-Touchscreen, USB/Ethernet und optionalen Tools für USB 2.0- und Ethernet-Tests.
Testwall kann den gebrauchten Tektronix DPO5054 liefern, vollständig getestet. Mit Expertenunterstützung und weltweiter Lieferung bietet Testwall leistungsstarke Instrumente mit hoher Zuverlässigkeit. Kontaktieren Sie uns für Kalibrierung oder Reparatur des Tektronix DPO5054.