Voltech

Voltech AT5600

Wound Component Tester
20 Hz – 3 MHz Messfrequenzbereich
0,1 % Grundmessgenauigkeit
L, C, R, Z, D, Q, ESR, θ, Wicklungsverhältnis, Phasenwinkel Testparameter
10 mV – 10 V RMS (programmierbar) Prüfspannung (AC)
Bis zu 200 mA RMS Prüfstrom (AC)
Datenblatt anfordern
Attribut Wert
Messfrequenzbereich 20 Hz – 3 MHz
Grundmessgenauigkeit 0,1 %
Testparameter L, C, R, Z, D, Q, ESR, θ, Wicklungsverhältnis, Phasenwinkel
Prüfspannung (AC) 10 mV – 10 V RMS (programmierbar)
Prüfstrom (AC) Bis zu 200 mA RMS
Anzahl der Testkanäle Bis zu 8 Kanäle (mit Multiplexer-Option)
Schnittstellen USB, RS-232, Handler-Schnittstelle, IEEE 488 (GPIB) optional
Messgeschwindigkeit Bis zu 50 Messungen pro Sekunde
Betriebstemperaturbereich 0 °C – 50 °C
Versorgungsspannung 90 – 264 V AC, 47 – 63 Hz
Voltech AT5600 Options:
  • AT5600 - Standard - Choose any 14 tests from the test listing; additional tests can be added later by entry of a simple key code
  • AT5600 - Gold - All available tests included from day one for maximum future proofing
Kalibrierungsformular Voltech AT5600

Reparaturformular Voltech AT5600
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelAT5600
 VOLTECH AT5600 Wound Component Tester  The AT5600 from Voltech is a complete integrated test solution for wound components, delivering accuracy, speed and reliability without compromise. The AT5600 allows 100% testing of any wound component on a single integrated unit. For both manufacturers of wound components and OEMs/ODMs performing incoming test, the AT5600 allows you to efficiently ensure quality and reliability. Uniquely in the market, the Voltech AT5600 can perform ALL of the tests required for multiple applications and any magnetic component type: from Hi-Pot and surge to magnetization, turns ratio, and winding resistance.  The AT5600 wound component tester can help you at the engineering stage, with in-depth type testing of your design and pre-production prototypes, enabling you to validate your design to any applicable standards such as BS EN 61558, UL 1876 and UL 1441. Features for the VOLTECH AT5600 Wound Component Tester Include:• Fast: 20 standard tests per second
• Superb accuracy
• Test ANY magnetic component: Ferrites, laminates, telecoms, SMPS transformer, EMC and other filters
• ANY combination of tests to suit your needs
• Integral 20 node matrix to test up to 10 windings in 4-wire Kelvin mode
• Integral 5kV AC / 7kV DC hi-pot
• Pass/fail, “audit test” and “test-on-fail” functions
• Four-wire connections throughout
• Voltech fixture system means no set up time for diffe transformer types
• Ethernet, RS232 and USB
• GUI with touch-screen
• Full results storage and program control; even program and monitor results over a network!
• Patented technology for core energization (improves test time)
• Patented technology for cur measurement (improves accuracy)
    