Yokogawa

Yokogawa 701260

Input Module, High-voltage, 100 KS/s, 16-bit isolation with RMS (2 channels)
16 Kanäle Messkanäle
100 MS/s Maximale Abtastrate
12 Bit Vertikale Auflösung
±10 V (maximal) Eingangsspannungsbereich
bis zu 16 MW pro Kanal Speichertiefe
Datenblatt anfordern
Attribut Wert
Messkanäle 16 Kanäle
Maximale Abtastrate 100 MS/s
Vertikale Auflösung 12 Bit
Eingangsspannungsbereich ±10 V (maximal)
Speichertiefe bis zu 16 MW pro Kanal
Bandbreite 20 MHz
Eingangsimpedanz 1 MΩ / 50 Ω umschaltbar
Kopplung AC / DC / GND
Zeitbasisbereich 1 ns/div bis 1000 s/div
Schnittstellenanschlüsse USB, Ethernet (LAN), GPIB (optional)
Yokogawa 701260 Options:
  • DL750 - /M1 - Memory expansion to 10 MW/CH
  • DL750 - /M2 - Memory expansion to 25 MW/CH
  • DL750 - /M3 - Memory expansion to 50 MW/CH
  • DL750 - /C8 - Internal 30 GB hard drive (FAT32)
  • DL750 - /C10 - Ethernet interface
  • DL750 - /G2 - User-defined math function
  • DL750 - /G3 - DSP channel function
  • DL750 - /P4 - Probe power (4-output)
  • DL750 - /DC - DC12 V power (DC10-18 V) (DL750 only)
  • 701260 - 700929 - Isolated probe, 1000 Vrms-CATII for 701260 (10:1)
  • 701260 - 701901 - 1:1 BNC safety adapter lead, 1000 Vrms-CATII for 701260
  • 701260 - 701959 - Safety mini clip (hook type), 1000 Vrms-CATII, 1 set each of red and black
  • 701260 - 701954 - Large Alligator clip (dolphin type), 1000 Vrms-CATII, 1 set each of red and black
  • 701260 - 758929 - Alligator adapter (rated volt.: 1000 V), 1000 Vrms-CATII, 1 set each of red and black
  • 701260 - 758922 - Alligator adapter (rated volt.: 300 V), 300 Vrms-CATII, 1 set each of red and black
  • 701260 - 758921 - Fork terminal adapter, 1000 Vrms-CATII, 1 set each of red and black
  • 701260 - 701940 - Passive probe for DL750/750P, Non-isolated 600 Vpk (10:1)
  • 701260 - 366926 - 1:1 BNC-alligator cable, Non-isolated 42 V or less, for 701250, -51, -55, 1 m
  • 701260 - 366961 - 1:1 Banana-alligator cable, Non-isolated 42 V or less, for 701261, -62, -65, 1.2 m
  • 701260 - 701933 - Current probe, 30 Arms, DC to 50 MHz, supports probe power
  • 701260 - 701930 - Current probe, 150 Arms, DC to 10 MHz, supports probe power
  • 701260 - 701931 - Current probe, 500 Arms, DC to 2 MHz, supports probe power
  • 701260 - 701934 - Probe power, large current output, external probe power supply (4 outputs)
  • 701260 - 700924 - Differential probe, 1400V pk, 1000 Vrms-CAT II
  • 701260 - 700986 - High-speed logic probe, 8-bit, non-isolated, response speed: 1µs
  • 701260 - 700987 - Isolated logic probe, 8-bit, each channel isolated, response speed: 20 ms (for AC)
  • 701260 - 758917 - Isolated logic measurement leads (2 per set)
  • 701260 - 366928 - Conversion adaptor, BNC (jack)-RCA (plug) conversion
  • 701260 - 701902 - Safety BNC cable (1 meter), 1000 Vrms-CATII (BNC-BNC)
  • 701260 - 701903 - Safety BNC cable (2 meters), 1000 Vrms-CATII (BNC-BNC)
  • 701260 - 758924 - Safety BNC-banana adapter, 500 Vrms-CATII, for 701250, -51, -55, -60
  • 701260 - 701963 - Soft carrying case for DL750, with 3 storage pockets
  • 701260 - 701967 - Soft carrying case for DL750P, with 3 storage pockets
  • 701260 - B9988AE - Printer roll paper, DL750, A6 size (120 mm wide x 10m), include 10 rolls
  • 701260 - 701966 - Printer roll paper, DL750P, A4 size (210 mm wide x 20m), include 6 rolls
  • 701260 - 701951 - Earphone Mic (w/ PUSH switch), for the voice memo function
Kalibrierungsformular Yokogawa 701260

Reparaturformular Yokogawa 701260
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
Model701260

YOKOGAWA 701260

The Yokogawa 701260 Input Module, offers high speed and 12-bit isolation. Specifications of the Yokogawa 701260 module include:

  • Input channels 2
  • Input couplings  AC, DC, GND, AC-RMS, DC-RMS
  • Maximum sampling rate  100 kS/s
  • A/D conversion resolution  16 bits (2400 LSB/div)
  • Input type Isolated unbalanced
  • Frequency range( €“3 dB)
    • Waveform measurement mode
      • DC, up to 40 kHz
    • RMS measurement mode
      • DC, 40 Hz to 10 kHz
  • Input range
    • (10:1)  200 mV/div to 2000 V/div (in steps of 1, 2, or 5)
    • (1:1)  20 mV/div to 200 V/div (in steps of 1, 2, or 5)
  • Effective measurement range  20 div (display range 10 div)
  • DC offset ±5 div
  • Maximum input voltage (1 kHz or less)
    • In combination with 700929(10:1)
      • 1000 V (DC + ACpeak)
    • In combination with 701901+701954 (1:1)
      • H side: 700 Vrms (CAT II) 7 , L side: 400 Vrms (CAT II)
  • Maximum allowable in-phase voltage
    • In combination with 700929 (10:1)
      • H side: 1000 Vrms (CAT II) 4 , L side: 400 Vrms (CAT II)
    • Direct input (when using a cable which doesn't comply with the safety standard)
      • H/L sides: 30 Vrms (42 V DC + ACpeak)
    • DC accuracy (waveform measurement mode)
      • ±(0.25% of 10 div)
    • DC accuracy (RMS measurement mode)
      • ±(1.0% of 10 div)
    • AC accuracy (RMS measurement mode)
      • Sine wave input ±(1.5% of 10 div)
    • Crest factor of 2 or less ±(2.0% of 10 div)
    • Crest factor of 3 or less ±(3.0% of 10 div)
  • Input impedance 1 M? ± 1%, approx. 35 pF
  • Connector type Isolation type BNC connector
  • Input filter   OFF, 100 Hz, 1 kHz, 10 kHz
  • Temperature coefficient
    • Zero point ±(0.02% of 10 div)/ °C (typical value)
    • Gain ±(0.02% of 10 div)/ °C (typical value)
Clicky Copyright © 2013-present Magento, Inc. All rights reserved.