Yokogawa
Yokogawa 720210
High-speed 100 MS/s 12-Bit Isolation Module (2 ch)
16 Kanäle Messkanäle
100 kS/s Maximale Abtastrate
16 Bit Auflösung
1 MΩ Eingangsimpedanz
±10 V Spannungsmessbereich

| Attribut | Wert |
|---|---|
| Messkanäle | 16 Kanäle |
| Maximale Abtastrate | 100 kS/s |
| Auflösung | 16 Bit |
| Eingangsimpedanz | 1 MΩ |
| Spannungsmessbereich | ±10 V |
| Isolationsspannung | 300 V AC (zwischen Kanälen) |
| Betriebstemperatur | 0 °C bis +50 °C |
| Kommunikationsschnittstelle | USB, GP-IB (IEEE 488) |
| Kompatibles Gerät | Yokogawa ScopeCorder / DL-Serie |
| Abmessungen (B × H × T) | Modulformat für DL750/DL850-Steckplatz |
Yokogawa 720210 Options:
- 720211 - 720211 - High-speed 100 MS/s 12 Bit Isolation Module
- 720250 - 720250 - High-speed 10 MS/s 12 Bit Isolation Module
- 701251 - 701251 - High-speed 1 MS/s 16 Bit Isolation Module
- 720254 - 720254 - 4 CH 1 MS/s 16 Bit Isolation Module
- 701255 - 701255 - High-speed 10 MS/s 12 Bit non-Isolation Module
- 720268 - 720268 - High-Voltage 1 MS/s, 16 Bit Isolation Module (with AAF, RMS)
- 720220 - 720220 - Voltage Input Module (16 CH)
- 701261 - 701261 - Universal Module
- 701262 - 701262 - Universal Module (with Anti-Aliasing Filter)
- 701265 - 701265 - Temperature/High-Precision Voltage Module
- 720266 - 720266 - Temperature/High-Precision Voltage Isolation Module (Low Noise)
- 720221 - 720221 - 16 CH Temperature/Voltage Input Module
- 701953 - 701953-L1 - 16 CH Scanner Box (provided with 1 m cable)
- 701953 - 701953-L3 - 16 CH Scanner Box (provided with 3 m cable)
- 701270 - 701270 - Strain Module (NDIS)
- 701271 - 701271 - Strain Module (DSUB, Shunt-CAL)
- 701275 - 701275 - Acceleration/Voltage Module (with Anti-Aliasing Filter)
- 720281 - 720281 - Frequency Module
- 720230 - 720230 - Logic Input Module
- 720240 - 720240 - CAN Bus Monitor Module
- 720241 - 720241 - CAN & LIN Bus Monitor Module
- 720243 - 720243 - SENT Monitor Module
- 720210 - 701947 - 100:1 Probe (for isolated BNC input) 1000 V (DC+ACpeak) CAT II, 1.5 m
- 720210 - 702902 - 10:1 Probe (for isolated BNC input) operating temp. range: -40 to 85°C, 2.5 m
- 720210 - 700929 - 10:1 Probe (for isolated BNC input) 1000 V (DC+ACpeak) CAT II, 1.5 m
- 720210 - 701901 - 1:1 Safety BNC adapter lead 1000 Vrms CAT II
- 720210 - 701904 - 1:1 Safety Adapter Lead 1000 Vrms CAT II, 600 Vrms CAT III
- 720210 - B9852MM - Safety mini-clip (Hook type) 1000 Vrms CAT III black
- 720210 - B9852MN - Safety mini-clip (Hook type) 1000 Vrms CAT III red
- 720210 - 701954 - Large alligator-clip (Dolphin type) 1000 Vrms CAT II, 1 set each of red and black
- 720210 - 758929 - Alligator clip adaptor set (Rated voltage 1000 V) 1000 Vrms CAT II, 1 set each of red and black
- 720210 - 758922 - Alligator clip adaptor set (Rated voltage 300 V) 300 Vrms CAT II, 1 set each of red and black
- 720210 - 758921 - Fork terminal adapter set 1000 Vrms CAT II, 1 set each of red and black
- 720210 - 701940 - Passive probe, Non-isolated 600 Vpk (701255) (10:1)
- 720210 - 366926 - 1:1 BNC-alligator cable Non-isolated 42 V or less, 1 m
- 720210 - 366961 - 1:1 Banana-alligator cable Non-isolated 42 V or less, 1.2 m
- 720210 - 701917 - Current probe 5 Arms, DC to 50 MHz
- 720210 - 701918 - Current probe 5 Arms, DC to 120 MHz
- 720210 - 701932 - Current probe 30 Arms, DC to 100 MHz
- 720210 - 701933 - Current probe 30 Arms, DC to 50 MHz
- 720210 - 701930 - Current probe 150 Arms, DC to 10 MHz
- 720210 - 701931 - Current probe 500 Arms, DC to 2 MHz
- 720210 - 720930 - Clamp-on probe AC 50 Arms
- 720210 - 720931 - Clamp-on probe AC 200 Arms
- 720210 - 701934 - Probe power supply, Large current output, external probe power supply (4 outputs)
- 720210 - 438920 - Shunt resistor 250 Ω ±0.1%
- 720210 - 438921 - Shunt resistor 100 Ω ±0.1%
- 720210 - 438922 - Shunt resistor 10 Ω ±0.1%
- 720210 - 700924 - Differential probe 1400 Vpk, 1000 Vrms CAT II
- 720210 - 700925 - Differential probe 500 Vpk, 350 Vrms (For 701255)
- 720210 - 701926 - Differential probe 7000 Vpk, 5000 Vrms
- 720210 - 701955 - Bridge head (NDIS, 120 Ω) With 5 m cable
- 720210 - 701956 - Bridge head (NDIS, 350 Ω) With 5 m cable
- 720210 - 701957 - Bridge head (DSUB, 120 Ω) shunt-CAL with 5 m cable
- 720210 - 701958 - Bridge head (DSUB, 350 Ω) shunt-CAL with 5 m cable
- 720210 - 758924 - Safety BNC-banana adapter 500 Vrms CAT II
- 720210 - B9988AE - Printer roll paper, One lot: 10 rolls, 10m each, for DL850E/EV
- 720210 - 702911 - Logic probe 8 bit, 1 m, non-Isolated, TTL level/Contact Input
- 720210 - 702912 - Logic probe 8 bit, 3 m, non-Isolated, TTL level/Contact Input
- 720210 - 700986 - High-speed logic probe 8 bit, non-Isolated, response speed: 1 µs (typ.)
- 720210 - 700987 - Isolation logic probe 8 bit, each channel isolated
- 720210 - 758917 - Measurement lead set, Measurement leads (2 per set)
- 720210 - 758933 - Measurement lead set 1000 V/19 A/1 m length
- 720210 - 701902 - Safety BNC-BNC cable (1 m) 1000 Vrms CAT II (BNC-BNC)
- 720210 - 701903 - Safety BNC-BNC cable (2 m) 1000 Vrms CAT II (BNC-BNC)
- 720210 - 701948 - Plug-on clip For 700929 and 701947
- 720210 - 701906 - Long test clip For 700924, 701901 and 701926
- 720210 - A1800JD - Terminal For 720220 input terminal, one (1) piece
- 720210 - 705926 - Connecting cables, Connecting cable for 701953 (1 m)
- 720210 - 705927 - Connecting cables, Connecting cable for 701953 (3 m)
| Model | 720210 |
|---|
YOKOGAWA 720210 ANALOG VOLTAGE INPUT MODULE
The Yokogawa 720210 is a high-speed, 12-bit, 2 channel, isolation, anolog voltage input module.
Specifications of the Yokogawa 720210 Analog Voltage Input Module include:
Specifications:
- Effective measurement range: Twice of setting range
- Number of input channels: 2
- Input coupling:
- AC, DC, and GND
- Maximum sample rate: 100 MS/s
- Input format: Isolated unbalanced
- Frequency characteristics (-3 dB point when sine wave of amplitude 60% of range is input): DC to 20 MHz
- Voltage-axis range setting: 50 mV to 200 V range (1-2-5 steps)
- Maximum input voltage (at a frequency of 1 kHz or less):
- Combined with the 700929 (10:1): 1000 V (DC + ACpeak) CATll
- Direct input or cable not complying with the safety standard: 200 V (DC + ACpeak)
- Maximum allowable common mode voltage (at a frequency of 1 kHz or less):
- Working voltage of safety standard combine with the 700929 (10:1): 1000 Vrms (CATll)
- Direct input or cable not complying with the safety standard: 42 V (DC + ACpeak) (CAT l and CAT ll, 30 Vrms)
- Vertical (voltage) axis accuracy (DC accuracy): 100mV to 200 V range: ±(0.5% of range)
- Input connector: BNC connector (isolated type)
- Input impedance: 1 MΩ ± 1%, approximately 35 pF
- -3 dB point when AC coupled low frequency attenuation point: 10 Hz or less (1 Hz or less when using the 700929)
- Common mode rejection ratio: 80 dB (50/60 Hz) or more (typical)
- Temperature measurement: 120 dB or more (50/60 Hz, with 2-Hz filter ON, signal source resistance of 500 Ω or less) typical
- Residual noise level (input section shorted): ±1.1 mV or 1.5% of range whichever is greater (typical)
- Withstand voltage: 1500 Vrms for 1 minute (across each terminal and earth) (60Hz)
- Insulation resistance: 500 VDC, 10 MΩ or more (across each terminal and earth)
- A/D conversion resolution: 12 bit (1500 LSB/range)
- Temperature coefficient:
- Zero point: 100 mV to 200 V range: ±(0.1% of range)/ C(typical)
- Gain: ±(0.05% of range)/ C(typical)
- Bandwidth limit:
- Select from OFF, 2 MHz, 1.28 MHz, 640 kHz, 320 kHz, 160 KHz, 80 kHz, 40 kHz, 20 kHz and 10 kHz
- Cut-off characteristics: -12 dB/OCT (when 2 MHz, typical)
- Probe attenuation setting:
- Voltage probe: 1:1, 10:1, 100:1, 1000:1
- Cur probe:
- 10 A:1 V for 700937/701933
- 100 A:1 V for 701930/701931