Fluke 4180

Black Body Calibrator -15C to 120C
-10°C to 1000°C (14°F to 1832°F) Temperature Range
±1°C or ±1% of reading (whichever is greater) Temperature Accuracy
0.100 to 1.000 (adjustable in 0.001 increments) Emissivity Range
50:1 Optical Resolution (D:S)
8 µm to 14 µm Spectral Response
Request datasheet
Attribute Value
Temperature Range -10°C to 1000°C (14°F to 1832°F)
Temperature Accuracy ±1°C or ±1% of reading (whichever is greater)
Emissivity Range 0.100 to 1.000 (adjustable in 0.001 increments)
Optical Resolution (D:S) 50:1
Spectral Response 8 µm to 14 µm
Display Backlit LCD with simultaneous IR and visible light imaging
Response Time Less than 500 ms (95% response)
Communication Interface USB and RS-232
Power Supply 4 AA alkaline batteries or AC adapter
Operating Temperature 0°C to 50°C (32°F to 122°F)
Calibration Form Fluke 4180

Repair Form Fluke 4180
Maximum file size: 40MB

No Related Posts

More Information
Model4180

 Fluke 4180 Black Body Calibrator

 

The  Fluke 4180 Black Body Calibrator is a  Precision Infrared calibrator designed for calibrating  infrared thermometers and thermal imagers within a specific temperature range.  It is  is fast, accurate, and easy to use.  Fluke 4180 Black Body Calibrator  comes with an accredited calibration from one of the world's most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making highquality infrared thermometer calibrations.

Fluke 4180 Black Body Calibrator  has a temperature range  temperatures from €“15 °C to 120 °C.  In addition, with accuracies as good as ± 0.35 °C the 4180 can meet its specifications without additional emissivity related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.  Most people associate a blackbody calibration source with calibrating infrared thermometers. Although the word blackbody specifically refers to an ideal surface that emits and absorbs electromagnetic radiation with the maximum amount of power possible at a given temperature, many calibrators with non-ideal surfaces are also referred to as "blackbody calibrators." Fluke 4180 Black Body Calibrator  can be radiometrically calibrated to correct for uncertainties caused by emissivity and heat loss at the surface of the "blackbody" calibration source.

 

Specifications for the  Fluke 4180 Black Body Calibrator Include:

Temperature range €“15 °C to 120 °C
Nominal emissivity 0.95
Stability ±0.10 °C at €“15 °C; ±0.05 °C at 0 °C; ±0.10 °C at 120 °C
Heating time 15 min: €“15 °C to 120 °C; 14 min: 23 °C to 120 °C

 