Fluke

Fluke 435-II

Power Quality Analyser, 3 Phase
CAT III 1000 V / CAT IV 600 V Measurement Categories
Voltage, Current, Frequency, Power (W), Apparent Power (VA), Reactive Power (VAR), Power Factor, Harmonics up to 50th order, Unbalance, Flicker Power Quality Parameters
1 V to 1000 V RMS (Phase to Neutral), 1 V to 1700 V RMS (Phase to Phase) Voltage Measurement Range
1 mA to 6000 A RMS (using compatible current clamps) Current Measurement Range
42.5 Hz to 69 Hz Frequency Range
Request datasheet
Attribute Value
Measurement Categories CAT III 1000 V / CAT IV 600 V
Power Quality Parameters Voltage, Current, Frequency, Power (W), Apparent Power (VA), Reactive Power (VAR), Power Factor, Harmonics up to 50th order, Unbalance, Flicker
Voltage Measurement Range 1 V to 1000 V RMS (Phase to Neutral), 1 V to 1700 V RMS (Phase to Phase)
Current Measurement Range 1 mA to 6000 A RMS (using compatible current clamps)
Frequency Range 42.5 Hz to 69 Hz
Energy Loss Calculator Calculates energy losses in watts and currency cost, including motor efficiency analysis
Memory / Data Storage Internal memory capable of storing up to 600 screen captures and extended trend logging via SD card (up to 2 GB)
Display Color VGA display, 320 x 240 pixels, sunlight-readable
Power Supply AC adapter (included) or rechargeable Li-ion battery pack; up to 8 hours battery life
Communication / Software USB interface with Fluke Energy Analyze Plus software for PC-based reporting and analysis
Fluke 435-II Options:
  • 435-II - I430-FLEXI-TF-4PK - 6000 A Fluke 430 Thin Flexi 61 cm (24 in) 4 pack
  • 435-II - C1740 - Softcase for 174X and 43X-II PQ Analyzer
  • 435-II - i5sPQ3 - 5 A ac Current Clamps, 3-pack
  • 435-II - i400s - i400s AC Current Clamp
  • 435-II - WC100 - Color Localization Set
  • 435-II - GPS430-II - GPS430 Time Synchronization Module
  • 435-II - BP291 - Double capacity Li-ion battery (up to 16 hr)
  • 435-II - HH290 - Hanging hook for use on cabinet doors
Calibration Form Fluke 435-II

Repair Form Fluke 435-II
Maximum file size: 40MB

No Related Posts

More Information
Model435-II

The Fluke 435 Series II Power Quality and Energy Analyzer delivers industry-leading accuracy in three-phase and single-phase power analysis, featuring patented Unified Power Measurement to quantify energy losses. It combines an energy loss calculator, PowerWave data capture, Class-A compliance (IEC 61000-4-30), waveform and transient capture, mains signaling measurement, and robust logging capabilities—all capped by the highest safety rating of 600 V CAT IV/1000 V CAT III with four flexible current probes.

Designed for engineers and technicians, the Fluke 435-II simplifies locating, predicting, preventing, and troubleshooting power quality issues. It supports measurements of harmonics, dips, swells, flicker, inrush, and unbalance across extensive scope, energy, and monitor modes for accurate system diagnostics.

Testwall can supply the used Fluke 435-II Power Quality and Energy Analyzer, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Fluke 435-II Power Quality and Energy Analyzer.