Fluke 9142

Field Metrology Well, -25C -150C w/INSA
-25°C to 140°C (-13°F to 284°F) Temperature Range
±0.005°C Temperature Stability
±0.01°C at 23°C Temperature Uniformity
0.001°C Display Resolution
Heating to 140°C in approximately 15 minutes; Cooling to -25°C in approximately 30 minutes Heating/Cooling Time
Request datasheet
Attribute Value
Temperature Range -25°C to 140°C (-13°F to 284°F)
Temperature Stability ±0.005°C
Temperature Uniformity ±0.01°C at 23°C
Display Resolution 0.001°C
Heating/Cooling Time Heating to 140°C in approximately 15 minutes; Cooling to -25°C in approximately 30 minutes
Well Depth 152 mm (6 in)
Well Diameter 25.4 mm (1 in) with interchangeable inserts
Reference Accuracy ±0.05°C
Power Requirements 100 V to 240 V AC, 50/60 Hz, 250 W maximum
Operating Environment 10°C to 50°C ambient temperature, up to 90% relative humidity (non-condensing)
Fluke 9142 Options:
  • 9142 - A - Field Metrology Well, –25 °C to 150 °C, Insert "A" Imperial Misc Holes
  • 9142 - B - Field Metrology Well, –25 °C to 150 °C, Insert "B" Imperial Comparison Holes
  • 9142 - C - Field Metrology Well, –25 °C to 150 °C, Insert "C" 0.25-inch Holes
  • 9142 - D - Field Metrology Well, –25 °C to 150 °C, Insert "D" Metric Comparison Holes
  • 9142 - E - Field Metrology Well, –25 °C to 150 °C, Insert "E" Metric Misc Holes w/0.25-inch Hole
  • 9142 - F - Field Metrology Well, –25 °C to 150 °C, Insert "F" Metric Comparison Misc Holes w/0.25-inch Hole
  • 9142 - A-P - Field Metrology Well, –25 °C to 150 °C, Insert "A" Imperial Misc Holes, w/Process Electronics
  • 9142 - B-P - Field Metrology Well, –25 °C to 150 °C, Insert "B" Imperial Comparison Holes, w/Process Electronics
  • 9142 - C-P - Field Metrology Well, –25 °C to 150 °C, Insert "C" 0.25-inch Holes, w/Process Electronics
  • 9142 - D-P - Field Metrology Well, –25 °C to 150 °C, Insert "D" Metric Comparison Holes, w/Process Electronics
  • 9142 - E-P - Field Metrology Well, –25 °C to 150 °C, Insert "E" Metric Misc Holes w/0.25-inch Hole, w/Process Electronics
  • 9142 - F-P - Field Metrology Well, –25 °C to 150 °C, Insert "F" Metric Comparison Misc Holes w/0.25-inch Hole, w/Process Electronics
  • 9142 - INSA - Insert "A" 9142, Imperial Misc Holes
  • 9142 - INSB - Insert "B" 9142, Imperial Comparison Holes
  • 9142 - INSC - Insert "C" 9142, 0.25-inch Holes
  • 9142 - INSD - Insert "D" 9142, Metric Comparison Holes
  • 9142 - INSE - Insert "E" 9142, Metric Misc Holes w/0.25-inch Hole
  • 9142 - INSF - Insert "F" 9142, Metric Comparison Misc Holes w/0.25-inch Hole
  • 9142 - INSZ - Insert "Z" 9142, Blank
  • 9142 - CASE - Carrying Case, 9142-4 Field Metrology Wells
Calibration Form Fluke 9142

Repair Form Fluke 9142
Maximum file size: 40MB

No Related Posts

More Information
Model9142

 Fluke  9142 Field Metrology Well

 

   The  Fluke  9142 Field Metrology Well is a Field Metrology Well that extends high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance. It offers exceptional accuracy, stability and portability, making it ideal for on-site calibration tasks.  This  Metrology Well is easy-to-use with  a large, easy-to-read LCD display, function keys, and menu navigation buttons.  Fluke  9142 Field Metrology Well has a built-in gradient-temperature compensation   that adjusts control characteristics to ensure stable performance in unstable environments.

   Fluke  9142 Field Metrology Well is packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate.  This industrial temperature loop calibrator  is perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the €œprocess " option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4 €“20 mA cur with 24 volt loop power.  9142 Field Metrology Well also has onboard automation and documentation.

 

Specifications for the  Fluke  9142 Field Metrology Well Include:

Temperature range €“25 °C to 150 °C ( €“13 °F to 302 °F)
Display Accuracy ± 0.2 °C
Stability ± 0.01 °C