Fluke

Fluke QA-ES III

Electrosurgical Analyzer and Tester
Tests monopolar, bipolar, and argon-enhanced coagulation modes Electrosurgical Unit Testing
0 to 400 W into 10, 25, 50, 100, 200, 300, 500, and 1000 Ω loads Power Measurement Range
100 kHz to 5 MHz Frequency Range
±2% of reading ±2 W Power Accuracy
1.0 to 10.0 Crest Factor Measurement
Request datasheet
Attribute Value
Electrosurgical Unit Testing Tests monopolar, bipolar, and argon-enhanced coagulation modes
Power Measurement Range 0 to 400 W into 10, 25, 50, 100, 200, 300, 500, and 1000 Ω loads
Frequency Range 100 kHz to 5 MHz
Power Accuracy ±2% of reading ±2 W
Crest Factor Measurement 1.0 to 10.0
Load Resistance Options 10 Ω, 25 Ω, 50 Ω, 100 Ω, 200 Ω, 300 Ω, 500 Ω, 1000 Ω
Patient Leakage Current Testing Tests return electrode monitoring (REM) and patient leakage current
Display Large backlit LCD display for easy reading in various lighting conditions
Standards Compliance IEC 60601-2-2, AAMI HF18, and IEC 61010-1
Power Supply AC power input: 100 V to 240 V, 50/60 Hz
Fluke QA-ES III Options:
  • QA-ES III - MK III-06 - QA-ES MK III Electrosurgery analyzer, US, non-wireless
  • QA-ES III - MK III-07 - QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless
  • QA-ES III - MK III-08 - QA-ES MK III Electrosurgery analyzer, UK, non-wireless
  • QA-ES III - MK III-09 - QA-ES MK III Electrosurgery analyzer, Japan, non-wireless
  • QA-ES III - MK III-10 - QA-ES MK III Electrosurgery analyzer, Australia, non-wireless
  • QA-ES III - MK III-11 - QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless
  • QA-ES III - MK III-13 - QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless
  • QA-ES III - TA-MK III-06 - QA-ES MK III Electrosurgery analyzer, US, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-07 - QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-08 - QA-ES MK III Electrosurgery analyzer, UK, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-09 - QA-ES MK III Electrosurgery analyzer, Japan, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-10 - QA-ES MK III Electrosurgery analyzer, Australia, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-11 - QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless with Ansur Automation Software
  • QA-ES III - TA-MK III-13 - QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless with Ansur Automation Software
Calibration Form Fluke QA-ES III

Repair Form Fluke QA-ES III
Maximum file size: 40MB

No Related Posts

More Information
ModelQA-ES III

 Fluke QA-ES III Electrosurgical Analyzer and Tester

 

   The  Fluke QA-ES III Electrosurgical Analyzer and Tester is a comprehensive electrosurgical analyzer designed to ensure the safety and performance of electrosurgical units used in healthcare settings. It is a vital tool for biomedical equipment technicians and healthcare facilities to maintain high standards of patient care.  With generator output cur accuracy as low as ± 2.5 %, the QA-ES III is capable of testing all modern high power electrosurgical units.  Fluke QA-ES III Electrosurgical Analyzer and Tester can test all critical ESU functions with precise power, current, frequency, crest factor and load resistance ranges.

   Fluke QA-ES III Electrosurgical Analyzer and Tester  Collect all measurements including vessel sealing, contact quality monitor (CQM), high frequency (HF) leakage and output power distribution in single or continuous mode. The QA-ES III has all hardware and software needed for complete testing, so you don't need to carry additional accessories or cables. It is user-friendly with large buttons, LCD screen, and guided test procedures to simplify operations. It supports ansur test automation software allows users to create and automatically run tests, capture data, and produce easy-to-read reports.  Fluke QA-ES III Electrosurgical Analyzer and Tester is having memory storage of up to 5,000 test records, eliminating the need to download data after the completion of each preventive maintenance or troubleshooting session.

 

Specifications for the  Fluke QA-ES III Electrosurgical Analyzer and Tester Include:

Bandwidth 30 Hz to 3MHz at -3 dB including loads
Cur (RMS) 0 mA to 5,500 mA
Voltage 10 kV Peak to Peak
Power Ranges 0.0 W to 99.9 W, 100 W to 500 W

 