Fluke QA-ES III

| Attribute | Value |
|---|---|
| Electrosurgical Unit Testing | Tests monopolar, bipolar, and argon-enhanced coagulation modes |
| Power Measurement Range | 0 to 400 W into 10, 25, 50, 100, 200, 300, 500, and 1000 Ω loads |
| Frequency Range | 100 kHz to 5 MHz |
| Power Accuracy | ±2% of reading ±2 W |
| Crest Factor Measurement | 1.0 to 10.0 |
| Load Resistance Options | 10 Ω, 25 Ω, 50 Ω, 100 Ω, 200 Ω, 300 Ω, 500 Ω, 1000 Ω |
| Patient Leakage Current Testing | Tests return electrode monitoring (REM) and patient leakage current |
| Display | Large backlit LCD display for easy reading in various lighting conditions |
| Standards Compliance | IEC 60601-2-2, AAMI HF18, and IEC 61010-1 |
| Power Supply | AC power input: 100 V to 240 V, 50/60 Hz |
Fluke QA-ES III Options:
- QA-ES III - MK III-06 - QA-ES MK III Electrosurgery analyzer, US, non-wireless
- QA-ES III - MK III-07 - QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless
- QA-ES III - MK III-08 - QA-ES MK III Electrosurgery analyzer, UK, non-wireless
- QA-ES III - MK III-09 - QA-ES MK III Electrosurgery analyzer, Japan, non-wireless
- QA-ES III - MK III-10 - QA-ES MK III Electrosurgery analyzer, Australia, non-wireless
- QA-ES III - MK III-11 - QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless
- QA-ES III - MK III-13 - QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless
- QA-ES III - TA-MK III-06 - QA-ES MK III Electrosurgery analyzer, US, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-07 - QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-08 - QA-ES MK III Electrosurgery analyzer, UK, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-09 - QA-ES MK III Electrosurgery analyzer, Japan, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-10 - QA-ES MK III Electrosurgery analyzer, Australia, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-11 - QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless with Ansur Automation Software
- QA-ES III - TA-MK III-13 - QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless with Ansur Automation Software
| Model | QA-ES III |
|---|
Fluke QA-ES III Electrosurgical Analyzer and Tester
The Fluke QA-ES III Electrosurgical Analyzer and Tester is a comprehensive electrosurgical analyzer designed to ensure the safety and performance of electrosurgical units used in healthcare settings. It is a vital tool for biomedical equipment technicians and healthcare facilities to maintain high standards of patient care. With generator output cur accuracy as low as ± 2.5 %, the QA-ES III is capable of testing all modern high power electrosurgical units. Fluke QA-ES III Electrosurgical Analyzer and Tester can test all critical ESU functions with precise power, current, frequency, crest factor and load resistance ranges.
Fluke QA-ES III Electrosurgical Analyzer and Tester Collect all measurements including vessel sealing, contact quality monitor (CQM), high frequency (HF) leakage and output power distribution in single or continuous mode. The QA-ES III has all hardware and software needed for complete testing, so you don't need to carry additional accessories or cables. It is user-friendly with large buttons, LCD screen, and guided test procedures to simplify operations. It supports ansur test automation software allows users to create and automatically run tests, capture data, and produce easy-to-read reports. Fluke QA-ES III Electrosurgical Analyzer and Tester is having memory storage of up to 5,000 test records, eliminating the need to download data after the completion of each preventive maintenance or troubleshooting session.
Specifications for the Fluke QA-ES III Electrosurgical Analyzer and Tester Include:
| Bandwidth | 30 Hz to 3MHz at -3 dB including loads |
| Cur (RMS) | 0 mA to 5,500 mA |
| Voltage | 10 kV Peak to Peak |
| Power Ranges | 0.0 W to 99.9 W, 100 W to 500 W |