California Instruments

California Instruments 18000L

AC Power Supply
18 000 VA (18 kVA) Puissance nominale
0 – 300 V CA (monophasé / triphasé) Tension de sortie
45 – 1 000 Hz Fréquence de sortie
3 phases (configuration triphasée) Nombre de phases
60 A par phase Courant de sortie maximal
Demander la fiche technique
Attribut Valeur
Puissance nominale 18 000 VA (18 kVA)
Tension de sortie 0 – 300 V CA (monophasé / triphasé)
Fréquence de sortie 45 – 1 000 Hz
Nombre de phases 3 phases (configuration triphasée)
Courant de sortie maximal 60 A par phase
Tension d'alimentation d'entrée 208 V CA triphasé / 50-60 Hz
Distorsion harmonique totale (THD) Inférieure à 0,5 % (charge linéaire)
Interface de programmation IEEE-488 (GPIB) et RS-232
Régulation de tension ± 0,1 % en charge statique
Dimensions (L x P x H) 482 mm x 711 mm x 355 mm (format rack 19")
California Instruments 18000L Options:
  • 18000L - P - Programmable controller (standard programmable, True RMS sensing)
  • 18000L - PT - Fast Transient programmable controller (real-time servo, fast settling)
  • 18000L - M - Manual control oscillator
  • 18000L - MODE - Allows IEEE-programmed or switch configured single-phase or three-phase output
  • 18000L - MT - Military applications controller option; CIIL and full confidence test
  • 18000L - RPV - Allows amplitude to be programmed with an external 0-10 VDC input (manual oscillator)
  • 18000L - SQW - Square wave capability with programmable controller
  • 18000L - 704 - MIL-STD-704 test routines embedded in -P and -PT controller
  • 18000L - 160 - RTCA/DO-160 test routines embedded in -PT controller
  • 18000L - HV - High voltage; changes output transformer to 156 V / 312 V, L-N
  • 18000L - EHV - Extra high voltage; changes output transformer to 200 V / 400 V, L-N (45 Hz to 1000 Hz only)
  • 18000L - LV - Low voltage; changes output transformer to 67.5 V / 135 V, L-N
  • 18000L - UP - Allows system to accept 3-phase L-L voltage from 342 V to 456 V, L-L
  • 18000L - LKM - Clock/Lock Master Unit; installs hardware to adapt to one slave unit
  • 18000L - LKS - Clock/Lock Slave Unit; installs hardware to accept Clock/Lock inputs from LKM unit
  • 18000L - 210960 - Rack slides; required for mounting in 19" (483 mm) instrument rack
Formulaire d'étalonnage California Instruments 18000L

Formulaire de réparation California Instruments 18000L
Maximum file size: 40MB

No Related Posts

Plus d'informations
Model18000L
California Instruments 18000L is an AC Power Supply