California Instruments
California Instruments 4500L
Power Source 4500 VA 45 Hz - 2 KHz.
4500 VA Puissance de sortie
0 - 300 V AC (monophasé) / 0 - 150 V AC (triphasé) Tension de sortie
45 Hz - 1000 Hz Fréquence de sortie
15 A par phase Courant de sortie maximum
Inférieure à 0,5 % Distorsion harmonique totale (THD)
6 600,00 € HT + livraison UE gratuite

| Attribut | Valeur |
|---|---|
| Puissance de sortie | 4500 VA |
| Tension de sortie | 0 - 300 V AC (monophasé) / 0 - 150 V AC (triphasé) |
| Fréquence de sortie | 45 Hz - 1000 Hz |
| Courant de sortie maximum | 15 A par phase |
| Distorsion harmonique totale (THD) | Inférieure à 0,5 % |
| Tension d'entrée | 208 V AC / 220 V AC / 230 V AC (triphasé) |
| Interface de programmation | GPIB (IEEE-488) et RS-232 |
| Configuration de phase | Monophasé ou triphasé (3 x 1500 VA) |
| Régulation de tension | ± 0,1 % en charge nominale |
| Dimensions (L x H x P) | 483 mm x 222 mm x 711 mm (format rack 5U) |
California Instruments 4500L Options:
- 4500L - -P - Programmable controller (single phase)
- 4500L - -3P - Programmable controller (three phase)
- 4500L - -PT - Fast Transient programmable controller (single phase)
- 4500L - -3PT - Fast Transient programmable controller (three phase)
- 4500L - -M - Manual control oscillator (single phase)
- 4500L - -3M - Manual control oscillator (three phase)
- 4500L - -MODE - Allows IEEE-programmed or switch configured single-phase or three-phase output
- 4500L - -MT - Military applications controller; CIIL and full confidence test
- 4500L - -RPV - Allows amplitude to be programmed with an external 0-10 VDC input (manual oscillator)
- 4500L - -SQW - Square wave capability with programmable controller
- 4500L - -704 - MIL-STD-704 test routines embedded in -P and -PT controller
- 4500L - -160 - RTCA/DO-160 test routines embedded in -PT controller
- 4500L - -HV - High voltage output transformer: 156 V / 312 V, L-N
- 4500L - -EHV - Extra high voltage output transformer: 200 V / 400 V, L-N (45 Hz to 1000 Hz only)
- 4500L - -LV - Low voltage output transformer: 67.5 V / 135 V, L-N
- 4500L - -AX - Separate isolated 26 VAC regulated and 5 VAC unregulated auxiliary outputs
- 4500L - -UP - Accepts 3-phase L-L input voltage from 342 V to 456 V, L-L
- 4500L - -LKM - Clock/Lock Master Unit hardware
- 4500L - -LKS - Clock/Lock Slave Unit hardware
- 4500L - 210960 - Rack slides for mounting in 19" (483 mm) instrument rack
| Model | 4500L |
|---|
The California Instruments 4500L AC Power Source offers Single or three phase Outputs with up to 4500 VA of Power from 45 Hz to 2 KHz.