Chroma
Chroma 19036
Wound Component Electrical Safety Test Analyser
0 - 600 V CC Tension de sortie
0 - 105 A Courant de sortie
15 000 W Puissance de sortie maximale
GPIB, RS-232, USB, Ethernet (en option) Interface de communication
± 0,1 % de la pleine échelle Précision de la tension

| Attribut | Valeur |
|---|---|
| Tension de sortie | 0 - 600 V CC |
| Courant de sortie | 0 - 105 A |
| Puissance de sortie maximale | 15 000 W |
| Interface de communication | GPIB, RS-232, USB, Ethernet (en option) |
| Précision de la tension | ± 0,1 % de la pleine échelle |
| Précision du courant | ± 0,2 % de la pleine échelle |
| Alimentation secteur requise | 208 / 220 / 380 / 400 V CA, triphasé, 50/60 Hz |
| Dimensions (L x H x P) | 483 x 266 x 700 mm |
| Poids | Environ 55 kg |
| Température de fonctionnement | 0 °C à 40 °C |
Chroma 19036 Options:
- 19036 - A190359 - 16ch HV External Scanning BOX
- 19036 - A190360 - 19' Rack Mount Kit
- 19036 - A190362 - 16ch 4-wire HV External Scanning Box
- 19036 - W25000099 - 4-wire Test Cable with bare wire (3m)
- 19036 - W25000100 - 4-wire Test Cable with bare wire (1.5m)
- 19036 - W25000104 - 4-wire Test Cable with Clip
| Model | 19036 |
|---|
Chroma 19036 Analyser The Chroma 19036 Wound Component Electrical Safety Test (EST) Analyser uniquely combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It is suitable for testing large leakage cur or big electrical safety equipment and can perform safety tests on wound components like motors, transformers and solenoid valve to verify their quality. The Chroma 19036 as a comprehensive tester integrated with high power hipot test and other safety tests can bring the maximum benefit to the production line as well as to quality assurance.Features and Specifications of the Chroma 19036 Wound Component EST Analyser include: Features: 10 Channels 5 in 1 composite Analyser: ACWV, DCWV, IR, Impulse, DCR Product Applications: Hi-pot test: Insulation Resistance test: Impulse Winding Test (IWT): DCR measurement: 5kVac / 6kVdc HSCC (High Speed Contact Check) 500 VA output 5kV Maximum 6kV impulse voltage High sampling rate (200MHz) 4-wire DCR measurement Δ / Y motor winding calculation Support maximum 40 channels scanning test USB waveform storage & hard copy function Graphic color display Standard LAN, USB, RS232 interface GFI (Ground Fault Interrupt) for body protection From EV motors, servomotors, ascension motors to fans, all rotary motor products need to perform impulse test, hi-pot and DCR measurements to ensure product quality DCR measurement is in 4-wire type Each terminal has Drive and Sense 10 independent channels for scanning Can test 3 DUTs at once to increase productivity Each channel can be set to Hi/Lo/Open respectively Specifications: AC/DC Withstanding Test: Insulation Resistance Test: Impulse Winding Test: DC Resistance Measurement: Flashover Detection: Interface: Output Voltage: Load Regulation: ≤ (1% of output+0.1% of full scale) Voltage Accuracy: ± (1% of setting+0.1% of full scale) Voltage Resolution: 2V Cutoff Cur: Cur Accuracy: ± (1% of reading+0.5% of range) Test Timer: Output Frequency: 50Hz / 60Hz (for AC) Waveform: Sine wave (for AC) AC: 0.05 - 5.0kV DC: 0.05 - 6.0kV AC: 0.001mA - 120mA(Voltage≤4kV) AC: 0.001mA - 100mA(Voltage>4kV) DC: 0.0001mA - 20mA Test time:0.3 - 999 sec., and continue Ramp/ Fall/Dwell time:0.1 - 999 sec., and off Output Voltage: Load Regulation: ≤(1%of output+0.1%of full scale) Voltage Accuracy: ±(1%of setting+0.1%of full scale) IR Range: 0.1MΩ - 50GΩ Resistance Accuracy: DC: 0.050 - 5.000kV Steps: 0.002kV >1kV: ≥0.5kV and ≤1kV: 1MΩ - 1GΩ: ±(3% of reading+0.1% of full range) 1GΩ - 10GΩ: ±(7% of reading+2% of full range ) 10GΩ - 50GΩ: ±(10% of reading+1% of full range) 0.1MΩ - 1GΩ: ±(3% of reading+0.1% of full range) 1GΩ - 10GΩ: ±(7% of reading+2% of full range ) 10GΩ - 50GΩ: ±(10% of reading+1% of full range) Applied Voltage: 0.5 - 6kV Step: 10V Energy: ,Max 0.21 Joules Induction Test Range: More than 10uH Sampling Speed: 10bit/ 5ns(200MHz) Sampling Range: 11 Ranges Pulse Number: Detection Mode: Area /Diffeial Area: Flutter/ Laplacian Detection Pulse Number: 1 - 32 Dummy Pulse Number: 0 - 9 Test Signal: Measurement Range: 0.1mΩ - 500kΩ Measurement Accuracy: 100m Ω: ± (0.5% of reading + 1% of full range) 1 Ω: ± (0.5% of reading + 0.2% of full range) 10 Ω: ± (0.5% of reading + 0.05% of full range) 100 Ω: ± (0.5% of reading + 0.05% of full range) 1k Ω: ± (0.5% of reading + 0.05% of full range) 10k Ω: ± (0.5% of reading + 0.05% of full range) 100k Ω: ± (0.5% of reading + 0.05% of full range) Detection Cur: Programmable setting AC: 20mA Programmable setting DC: 10mA Contact Check Function: Electrical Hazard Protection Function: Contact Check: OSC (open/short check0 HFCC (High Frequency Contact Check) HSCC (High Speed Contact Check; winding DCR check) Ground Fault Interrupt: 0.5mA±0.25mAAC,ON/OFF Key Lock: Yes (password control) Interlock: Yes Indication, Alarm: Memory Storage: 200 sets, maximum 40 steps per set Go: Short sound, Green LED NG: Long sound, Red LED Standard: RS232, Handler, USB, LAN interface
- 10 Channels
- 5 in 1 composite Analyser: ACWV, DCWV, IR, Impulse, DCR
- Hi-pot test:
- 5kVac / 6kVdc
- HSCC (High Speed Contact Check)
- 500 VA output
- Insulation Resistance test:
- 5kV Maximum
- Impulse Winding Test (IWT):
- 6kV impulse voltage
- High sampling rate (200MHz)
- DCR measurement:
- 4-wire DCR measurement
- Δ / Y motor winding calculation
- Support maximum 40 channels scanning test
- USB waveform storage & hard copy function
- Graphic color display
- Standard LAN, USB, RS232 interface
- GFI (Ground Fault Interrupt) for body protection
- Product Applications:
- From EV motors, servomotors, ascension motors to fans, all rotary motor products need to perform impulse test, hi-pot and DCR measurements to ensure product quality
- DCR measurement is in 4-wire type
- Each terminal has Drive and Sense
- 10 independent channels for scanning
- Can test 3 DUTs at once to increase productivity
- Each channel can be set to Hi/Lo/Open respectively
- Hi-pot test:
- 5kVac / 6kVdc
- HSCC (High Speed Contact Check)
- 500 VA output
- Insulation Resistance test:
- 5kV Maximum
- Impulse Winding Test (IWT):
- 6kV impulse voltage
- High sampling rate (200MHz)
- DCR measurement:
- 4-wire DCR measurement
- Δ / Y motor winding calculation
- Support maximum 40 channels scanning test
- USB waveform storage & hard copy function
- Graphic color display
- Standard LAN, USB, RS232 interface
- GFI (Ground Fault Interrupt) for body protection
- From EV motors, servomotors, ascension motors to fans, all rotary motor products need to perform impulse test, hi-pot and DCR measurements to ensure product quality
- DCR measurement is in 4-wire type
- Each terminal has Drive and Sense
- 10 independent channels for scanning
- Can test 3 DUTs at once to increase productivity
- Each channel can be set to Hi/Lo/Open respectively
- 5kVac / 6kVdc
- HSCC (High Speed Contact Check)
- 500 VA output
- 5kV Maximum
- 6kV impulse voltage
- High sampling rate (200MHz)
- 4-wire DCR measurement
- Δ / Y motor winding calculation
- AC/DC Withstanding Test:
- Output Voltage:
- AC: 0.05 - 5.0kV
- DC: 0.05 - 6.0kV
- Load Regulation: ≤ (1% of output+0.1% of full scale)
- Voltage Accuracy: ± (1% of setting+0.1% of full scale)
- Voltage Resolution: 2V
- Cutoff Cur:
- AC: 0.001mA - 120mA(Voltage≤4kV)
- AC: 0.001mA - 100mA(Voltage>4kV)
- DC: 0.0001mA - 20mA
- Cur Accuracy: ± (1% of reading+0.5% of range)
- Test Timer:
- Test time:0.3 - 999 sec., and continue
- Ramp/ Fall/Dwell time:0.1 - 999 sec., and off
- Output Frequency: 50Hz / 60Hz (for AC)
- Waveform: Sine wave (for AC)
- Insulation Resistance Test:
- Output Voltage:
- DC: 0.050 - 5.000kV
- Steps: 0.002kV
- Load Regulation: ≤(1%of output+0.1%of full scale)
- Voltage Accuracy: ±(1%of setting+0.1%of full scale)
- IR Range: 0.1MΩ - 50GΩ
- Resistance Accuracy:
- >1kV:
- 1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- ≥0.5kV and ≤1kV:
- 0.1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- Impulse Winding Test:
- Applied Voltage: 0.5 - 6kV
- Step: 10V
- Energy: ,Max 0.21 Joules
- Induction Test Range: More than 10uH
- Sampling Speed: 10bit/ 5ns(200MHz)
- Sampling Range: 11 Ranges
- Pulse Number:
- Pulse Number: 1 - 32
- Dummy Pulse Number: 0 - 9
- Detection Mode: Area /Diffeial Area: Flutter/ Laplacian Detection
- DC Resistance Measurement:
- Test Signal:
- Measurement Range: 0.1mΩ - 500kΩ
- Measurement Accuracy:
- 100m Ω: ± (0.5% of reading + 1% of full range)
- 1 Ω: ± (0.5% of reading + 0.2% of full range)
- 10 Ω: ± (0.5% of reading + 0.05% of full range)
- 100 Ω: ± (0.5% of reading + 0.05% of full range)
- 1k Ω: ± (0.5% of reading + 0.05% of full range)
- 10k Ω: ± (0.5% of reading + 0.05% of full range)
- 100k Ω: ± (0.5% of reading + 0.05% of full range)
- Flashover Detection:
- Detection Cur:
- Programmable setting AC: 20mA
- Programmable setting DC: 10mA
- Contact Check Function:
- Contact Check:
- OSC (open/short check0
- HFCC (High Frequency Contact Check)
- HSCC (High Speed Contact Check; winding DCR check)
- Electrical Hazard Protection Function:
- Ground Fault Interrupt: 0.5mA±0.25mAAC,ON/OFF
- Key Lock: Yes (password control)
- Interlock: Yes
- Indication, Alarm:
- Go: Short sound, Green LED
- NG: Long sound, Red LED
- Memory Storage: 200 sets, maximum 40 steps per set
- Interface:
- Standard: RS232, Handler, USB, LAN interface
- Output Voltage:
- AC: 0.05 - 5.0kV
- DC: 0.05 - 6.0kV
- Load Regulation: ≤ (1% of output+0.1% of full scale)
- Voltage Accuracy: ± (1% of setting+0.1% of full scale)
- Voltage Resolution: 2V
- Cutoff Cur:
- AC: 0.001mA - 120mA(Voltage≤4kV)
- AC: 0.001mA - 100mA(Voltage>4kV)
- DC: 0.0001mA - 20mA
- Cur Accuracy: ± (1% of reading+0.5% of range)
- Test Timer:
- Test time:0.3 - 999 sec., and continue
- Ramp/ Fall/Dwell time:0.1 - 999 sec., and off
- Output Frequency: 50Hz / 60Hz (for AC)
- Waveform: Sine wave (for AC)
- Output Voltage:
- DC: 0.050 - 5.000kV
- Steps: 0.002kV
- Load Regulation: ≤(1%of output+0.1%of full scale)
- Voltage Accuracy: ±(1%of setting+0.1%of full scale)
- IR Range: 0.1MΩ - 50GΩ
- Resistance Accuracy:
- >1kV:
- 1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- ≥0.5kV and ≤1kV:
- 0.1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- Applied Voltage: 0.5 - 6kV
- Step: 10V
- Energy: ,Max 0.21 Joules
- Induction Test Range: More than 10uH
- Sampling Speed: 10bit/ 5ns(200MHz)
- Sampling Range: 11 Ranges
- Pulse Number:
- Pulse Number: 1 - 32
- Dummy Pulse Number: 0 - 9
- Detection Mode: Area /Diffeial Area: Flutter/ Laplacian Detection
- Test Signal:
- Measurement Range: 0.1mΩ - 500kΩ
- Measurement Accuracy:
- 100m Ω: ± (0.5% of reading + 1% of full range)
- 1 Ω: ± (0.5% of reading + 0.2% of full range)
- 10 Ω: ± (0.5% of reading + 0.05% of full range)
- 100 Ω: ± (0.5% of reading + 0.05% of full range)
- 1k Ω: ± (0.5% of reading + 0.05% of full range)
- 10k Ω: ± (0.5% of reading + 0.05% of full range)
- 100k Ω: ± (0.5% of reading + 0.05% of full range)
- Detection Cur:
- Programmable setting AC: 20mA
- Programmable setting DC: 10mA
- Contact Check Function:
- Contact Check:
- OSC (open/short check0
- HFCC (High Frequency Contact Check)
- HSCC (High Speed Contact Check; winding DCR check)
- Electrical Hazard Protection Function:
- Ground Fault Interrupt: 0.5mA±0.25mAAC,ON/OFF
- Key Lock: Yes (password control)
- Interlock: Yes
- Indication, Alarm:
- Go: Short sound, Green LED
- NG: Long sound, Red LED
- Memory Storage: 200 sets, maximum 40 steps per set
- Standard: RS232, Handler, USB, LAN interface
- AC: 0.05 - 5.0kV
- DC: 0.05 - 6.0kV
- AC: 0.001mA - 120mA(Voltage≤4kV)
- AC: 0.001mA - 100mA(Voltage>4kV)
- DC: 0.0001mA - 20mA
- Test time:0.3 - 999 sec., and continue
- Ramp/ Fall/Dwell time:0.1 - 999 sec., and off
- DC: 0.050 - 5.000kV
- Steps: 0.002kV
- >1kV:
- 1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- ≥0.5kV and ≤1kV:
- 0.1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- 1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- 0.1MΩ - 1GΩ: ±(3% of reading+0.1% of full range)
- 1GΩ - 10GΩ: ±(7% of reading+2% of full range )
- 10GΩ - 50GΩ: ±(10% of reading+1% of full range)
- Pulse Number: 1 - 32
- Dummy Pulse Number: 0 - 9
- 100m Ω: ± (0.5% of reading + 1% of full range)
- 1 Ω: ± (0.5% of reading + 0.2% of full range)
- 10 Ω: ± (0.5% of reading + 0.05% of full range)
- 100 Ω: ± (0.5% of reading + 0.05% of full range)
- 1k Ω: ± (0.5% of reading + 0.05% of full range)
- 10k Ω: ± (0.5% of reading + 0.05% of full range)
- 100k Ω: ± (0.5% of reading + 0.05% of full range)
- Programmable setting AC: 20mA
- Programmable setting DC: 10mA
- Contact Check:
- OSC (open/short check0
- HFCC (High Frequency Contact Check)
- HSCC (High Speed Contact Check; winding DCR check)
- Ground Fault Interrupt: 0.5mA±0.25mAAC,ON/OFF
- Key Lock: Yes (password control)
- Interlock: Yes
- Indication, Alarm:
- Go: Short sound, Green LED
- NG: Long sound, Red LED
- Memory Storage: 200 sets, maximum 40 steps per set
- OSC (open/short check0
- HFCC (High Frequency Contact Check)
- HSCC (High Speed Contact Check; winding DCR check)
- Go: Short sound, Green LED
- NG: Long sound, Red LED