Chroma
Chroma 63212A-600-840
High Power DC Electronic Load, 600V, 840A, 12kW
600 V Tension maximale
840 A Courant maximal
Jusqu'à 42 000 W Puissance maximale
2 canaux indépendants Nombre de canaux
CC, CV, CR, CP Modes de fonctionnement

| Attribut | Valeur |
|---|---|
| Tension maximale | 600 V |
| Courant maximal | 840 A |
| Puissance maximale | Jusqu'à 42 000 W |
| Nombre de canaux | 2 canaux indépendants |
| Modes de fonctionnement | CC, CV, CR, CP |
| Interface de communication | GPIB, USB, RS-232, Ethernet (LAN) |
| Fréquence d'échantillonnage | Jusqu'à 50 kHz |
| Protection intégrée | Surintensité, surtension, surchauffe, inversion de polarité |
| Refroidissement | Ventilation forcée par ventilateurs internes |
| Format mécanique | Format rack 19 pouces |
Chroma 63212A-600-840 Options:
- 63212A-600-840 - A600009 - GPIB cable (200cm)
- 63212A-600-840 - A600010 - GPIB cable (60cm)
- 63212A-600-840 - A632000 - Softpanel for 63200A Series
- 63212A-600-840 - A632006 - NI USB-6211 Bus-Powered Multifunction DAQ
- 63212A-600-840 - A636000 - GPIB interface
- 63212A-600-840 - A636010 - Ethernet interface
- 63212A-600-840 - B632002 - Rack mounting kit for 7U models (8kW/10kW/12kW)
| Model | 63212A-600-840 |
|---|
Chroma 63212A-600-840 Programmable DC Electronic Load The 63212A series high power DC electronic loads are designed for testing a wide range of products including AC/DC and server power supplies, DC/DC converters, EV batteries, automotive charging stations, and other power electronics components. Each model has 3 power ranges, they can precisely measure the voltage and cur in real time. The Chroma 63212A-600-840 DC load offers high speed, programmable dynamic loading (CCD: Dynamic Cur Loading & CRD: Dynamic Resistance Loading) and sweep simulation for testing. The Chroma 63212A-600-840 electronic DC loads operate in constant voltage, cur, resistance, or power modes to satisfy a wide range of test requirements. A built-in highly precision A/D converter, achieving 0.015%+0.015%F.S., 0.04%+0.04%F.S. and 0.1%+0.1%F.S. accuracy for voltage, cur and power measurement respectively. The unique CZ mode designed in the Chroma 63212A-600-840 series can improve the loading behavior of CC & CP mode and makes the simulated loading cur more realistic. In addition, the Chroma 63212A-600-840 high power DC load also provides voltage peak measurement during actual loading conditions, avoiding the need for using an Oscilloscope to capture the voltage peak, saving time and costs. Specifications for the Chroma 63212A-600-840 Programmable DC Electronic load include: