emtest

emtest HFK

Capacitive Coupling Clamp
100 kHz – 230 MHz Plage de fréquence
50 Ω Impédance de sortie
Jusqu'à 400 V crête Niveau de tension de sortie
Sinusoïdale modulée en amplitude Forme d'onde
80 % AM à 1 kHz Taux de modulation
Demander la fiche technique
Attribut Valeur
Plage de fréquence 100 kHz – 230 MHz
Impédance de sortie 50 Ω
Niveau de tension de sortie Jusqu'à 400 V crête
Forme d'onde Sinusoïdale modulée en amplitude
Taux de modulation 80 % AM à 1 kHz
Conformité aux normes IEC 61000-4-6, ISO 11452-4
Interface de contrôle USB, GPIB, RS-232
Alimentation électrique 100 – 240 V CA, 50/60 Hz
Température de fonctionnement 0 °C à +40 °C
Dimensions (L x l x H) 420 mm x 380 mm x 133 mm
emtest HFK Options:
  • HFK - CA EFT Kit - Calibration Kit for EFT Burst calibration includes: KW 50 50ohm load resistor, KW 1000 1,000ohm load resistor, AD-CA EFT Adapter 4mm/6mm to coaxial F103 connector (connection Load resistor to transducer plate)
  • HFK - AD-CA EFT - Adapter to match the transducer plate to the KW 50 load resistor (connection Load resistor to transducer plate)
  • HFK - KW 50 - Coaxial 50ohm load resistor for EFT/Burst transient calibration
Formulaire d'étalonnage emtest HFK

Formulaire de réparation emtest HFK
Maximum file size: 40MB

No Related Posts

Plus d'informations
ModelHFK
emtest HFK Capacitive Coupling ClampThe emtest HFK is used to couple EFT/burst pulses to I/O lines as required in diffe European and international standards for immunity testing. The coupling of the Electrical Fast Transients EFT/burst to signal lines can usually not be achieved by discrete capacitive coupling without interfering with the signal flow. It is often impossible to contact the required circuit (direct), e. g. coaxial or shielded cables. In this case the coupling is realized by the capacitive coupling clamp. The interference simulator can be connected on both sides of the coupling clamp.

Features of the emtest HFK include:
  • Connects directly to the emtest UCS 500N5. And with adapters, it connects to the emtest NX5 Compact Immunity Tester
  • Construction as per IEC 61000-4-4 Ed.3
  • EFT/Burst testing of signal- and datalines
  • Active coupling length 1m
  • Permissable burst voltage 7 kV
  • For cable diameter up to 40 mm
  • The HFK Capactive Coupling Clamp is identical to the emtest CCI Capacitive Coupling Clamp, except that it requires adapters to connect the NX5 without the need for adapters.     