Fluke 568-EX

| Attribut | Valeur |
|---|---|
| Plage de mesure de température infrarouge | -40 °C à +800 °C (-40 °F à +1472 °F) |
| Précision infrarouge | ±1 % de la lecture ou ±1 °C (selon la valeur la plus élevée) |
| Rapport distance/point (D:S) | 50:1 |
| Plage de mesure du thermocouple de contact | -40 °C à +260 °C (-40 °F à +500 °F) |
| Émissivité réglable | 0,10 à 1,00 (réglable par incréments de 0,01) |
| Classification de sécurité | ATEX/IECEx Zone 1 et Zone 2 (antidéflagrant) |
| Indice de protection | IP54 (résistant à la poussière et aux projections d'eau) |
| Affichage | Écran LCD rétroéclairé avec double affichage simultané IR et contact |
| Alimentation | 2 piles AA 1,5 V (autonomie d'environ 10 heures) |
| Température de fonctionnement | -10 °C à +50 °C (14 °F à 122 °F) |
| Model | 568-EX |
|---|
Fluke 568-EX Intrinsically Safe Mini Infrared Thermometer
The Fluke 568-EX Intrinsically Safe Mini Infrared Thermometer is the one product which can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. With a straight-forward user interface and soft key menus, the Fluke 568 Ex makes even complex measurements very easy. With just a few pushes of a button, users can adjust emissivity, record data, or turn on and off alarms. All in a single intrinsically safe tool certified by major rating bodies from around the world.
Fluke 568-EX Intrinsically Safe Mini Infrared Thermometer confidently measures a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table. The 50:1 distance-to-spot ratio allows users to measure smaller objects from further away. It is also compatible with mini-connector K-type thermocouple (KTC) probe. Fluke 568-EX can captures up to 99 points of data for quick downloading to a PC through the USB connection. Featuring rugged and ergonomic design, Fluke 568 is built to withstand tough industrial, electrical, HVAC, and mechanical environments.
Specifications for the Fluke 568-EX Intrinsically Safe Mini Infrared Thermometer Include:
| Infrared temperature range | -40 °C to 800 °C (-40 °F to 1472 °F) |
| Display resolution | 0.1 °C / 0.1 °F |
| Infrared spectral response | 8 µm to 14 µm |
| Infrared response time | < 500 msec |