Fluke

Fluke OFP-100-Q

OptiFiber Pro Quad OTDR Kit
VCSEL 850/1300 nm Type de source lumineuse
850 nm et 1300 nm (multimode) Plage de longueurs d'onde
SC/ST/LC (adaptateurs interchangeables) Type de connecteur
-60 dBm à +3 dBm Plage de puissance optique
±0,2 dB Précision de mesure
Demander la fiche technique
Attribut Valeur
Type de source lumineuse VCSEL 850/1300 nm
Plage de longueurs d'onde 850 nm et 1300 nm (multimode)
Type de connecteur SC/ST/LC (adaptateurs interchangeables)
Plage de puissance optique -60 dBm à +3 dBm
Précision de mesure ±0,2 dB
Type de fibre compatible Fibre optique multimode (OM1, OM2, OM3, OM4)
Autonomie de la batterie Jusqu'à 150 heures en utilisation continue
Affichage Écran LCD rétroéclairé
Certification et conformité CE, conforme aux normes IEC 61010-1
Plage de température de fonctionnement -10 °C à +50 °C
Formulaire d'étalonnage Fluke OFP-100-Q

Formulaire de réparation Fluke OFP-100-Q
Maximum file size: 40MB

No Related Posts

Plus d'informations
ModelOFP-100-Q

 FLUKE OFP-100-Q OptiFiber Pro Quad OTDR Kit

 

With its simple smartphone user interface and powerful feature set, the Fluke OFP-100-Q turns anyone into an efficient and expert premise fiber troubleshooter or installer. The Fluke OFP-100-Q leverages the most sophisticated optical technology to provide the shortest event dead zone (0.5 m typical for MM) and attenuation dead zone (2.2 m typical for MM and 3.6 m typical for SM) of any OTDR. Leveraging the popular and multi-featured LinkWare cable test management software application, OptiFiber Pro users can easily access the hassle-free project management, report generation, and software upgrade capabilities to manage workflow and consolidate test results.

Another breakthrough with the Fluke OFP-100-Q is the data acquisition speed. While in Quick Test mode, a complete set of data is acquired in as little as two seconds per wavelength. OptiFiber Pro then analyzes the data and displays it as an EventMap event, Table or Trace. The end result is less time spent testing and more time performing other tasks. With a simple one-touch selection, users enter DataCenter OTDR mode €“ without setup time for fine tuning as needed in legacy OTDRs. DataCenter OTDR mode automatically detects OTDR parameters €“ end-detection algorithms, pulse widths, etc €“ without getting confused by the short links or number of connectors. The Fluke OFP-100-Q is the industry's first purpose-built OTDR that meets the unique challenges of an enterprise fiber infrastructure.

 

Specifications for the  FLUKE OFP-100-Q OptiFiber Pro Quad OTDR Kit Include:

Wavelengths 850 nm +/- 10 nm, 1300 nm +35/-15 nm, 1310 nm +/- 25 nm, 1550 nm +/- 30 nm
Sample Resolution 3 cm - 400  cm
Max Distance Range Setting MM 40 km / SM 130 km
Quick Test Time Setting MM 2 sec (typical) SM 5 sec (typical)

 