Hipotronics

Hipotronics 880PL-10MA

DC Hipot, 80 kV, 10 mA
80 kV DC Tension de sortie maximale
10 mA Courant de sortie
800 W Puissance nominale
Courant continu (DC) Type de tension de sortie
0,1 % ou mieux Régulation de tension
Demander la fiche technique
Attribut Valeur
Tension de sortie maximale 80 kV DC
Courant de sortie 10 mA
Puissance nominale 800 W
Type de tension de sortie Courant continu (DC)
Régulation de tension 0,1 % ou mieux
Ondulation de sortie Inférieure à 0,5 % crête à crête
Tension d'alimentation 115/230 V CA, 50/60 Hz
Interface de contrôle Panneau de commande frontal avec contrôle manuel
Protection intégrée Protection contre les surcharges et les courts-circuits
Application principale Tests diélectriques et essais haute tension
Hipotronics 880PL-10MA Options:
  • 880PL-10MA - HHDA13-280 - 120kV rated grounding stick
  • 880PL-10MA - HH-SAFE - Safety strobe light with magnetic base
  • 880PL-10MA - HH-FS - Foot operated interlock switch
  • 880PL-10MA - EXT-WARN - External Warning Lamp
  • 880PL-10MA - HH-HS - Hand operated interlock switch
  • 880PL-10MA - WARRANTY-2YR - Warranty Extension to 2 years
  • 880PL-10MA - WARRANTY-3YR - Warranty Extension to 3 years
Formulaire d'étalonnage Hipotronics 880PL-10MA

Formulaire de réparation Hipotronics 880PL-10MA
Maximum file size: 40MB

No Related Posts

Plus d'informations
Model880PL-10MA

RENT Hiptronics 880PL-10MA (call for availability)

The Hiptoronics 880PL-10mA DC hipot tester is an economical solution to DC field testing of cables, terminations, motors, generators and other electrical apparatus. The Hipotronics 880PL10-MA 80kV and is self-contained in a single, rugged and durable enclosure, which is complete from input line cord to high voltage output cable. Cable storage space is conveniently located inside.

The 880PL testers features accurate kV meter readings regardless of load current. Accurate voltage and cur measurements are assured via voltage readings that are taken directly at the output of the high voltage transformer and cur measurements are taken in the return leg. Safe discharging of both the test object and the high voltage transformer occur whenever the high voltage is turned off. Output power is provided by means of a full-wave voltage doubling rectifier circuit with silicon rectifiers.

Features of the Hipotronics 880PL-10MA include:

  • Rugged, portable single-piece construction
  • Shielded output cable
  • Full-wave voltage doubling rectifier circuit
  • Zero start interlock and guard circuit
  • Internal discharge solenoid
  • Meter accuracy ± 2% full scale
  • 10 mA cur rating for cable charging
  • External interlock provisions
  • Three range voltmeter
  • Four range cur meter
  • No internal leakage at full load
  • Instantaneous overload relay
  • Surge-limiting resistors in HV output

Benefits of the Hipotronics 880PL include:

  • Ideal for field testing €“ compact, lightweight and rugged makes it suitable for field orientated applications
  • Operator Safety €“ the power supply and test object are automatically grounded when high voltage is turned off and there is no exposed high voltage
  • Simple to Use - a minimal amount of setup time and a simple control panel allows simple testing every time
  • Accurate Leakage Cur Measurement - while guard circuit eliminates stray leakage currents

Technical Specifications for the Hipotronics 880PL-10MA:

  • Input Voltage: 120V, 50/60 Hz
  • Output Voltage: 0-80 KV
  • Output Current: 10 mA
  • Polarity: Negative Output, Possitive Ground
  • Metering: + 2% full scale accuracy
  • Ripple: 0.5% per mA with rated resistance

Hipotronics 880PL-10MA

 

Click Here To See Other  

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.