Keysight (Agilent) 89430A

| Attribut | Valeur |
|---|---|
| Plage de fréquences | DC à 10 MHz |
| Nombre de canaux | 2 canaux d'entrée |
| Plage dynamique | 90 dB |
| Résolution en fréquence | 1 mHz |
| Impédance d'entrée | 50 Ω / 1 MΩ |
| Plage de tension d'entrée | -50 dBm à +30 dBm |
| Type d'analyseur | Analyseur de signal vectoriel (VSA) |
| Largeur de bande de résolution | 1 mHz à 3 MHz |
| Interface de communication | GPIB (IEEE-488) |
| Alimentation électrique | 100-240 V CA, 50/60 Hz |
Keysight (Agilent) 89430A Options:
- 89430A - AYA - Vector Modulation Analysis (Option UFG recommended)
- 89430A - AYB - Waterfall and Spectrogram (Option UFG recommended)
- 89430A - AYC - Freq. Reference Retrofit (reverses Opt. AY4) - Retrofit at service center only
- 89430A - AYH - Digital Video Modulation Analysis (Options AYA, UFG required)
- 89430A - AY4 - Delete Precision Frequency Reference (Retrofit unavailable)
- 89430A - AY5 - Precision Frequency Reference - Retrofit at service center only
- 89430A - AY7 - Second 10 MHz Input Channel
- 89430A - AY8 - Internal RF Source - Retrofit at factory (HP 89440/430A)
- 89430A - AY9 - Extend Time Capture to 1 Msample
- 89430A - UE2 - Firmware Upgrade (HP 894XXU only)
- 89430A - UFG - 4 MB Extended RAM, Additional I/O
- 89430A - UG7 - Advanced LAN Support (Option UFG required)
- 89430A - UK6 - Commercial Calibration Certificate (Retrofit unavailable)
- 89430A - 1C2 - HP Instrument BASIC
- 89430A - 1D7 - 50-75 Ohm Minimum Loss Pad
- 89430A - 1F0 - PC-style Keyboard - U.S. version
- 89430A - AX3 - Front Handle Kit
- 89430A - AX4 - Rack Flange Kit
- 89430A - AX5 - Flange and Handle Kit
- 89430A - 0B1 - Extra Manual Set
- 89430A - 0BU - Extra Instrument BASIC Manuals
- 89430A - 0B3 - Service Manual
- 89430A - AVK - Printed Version of Online Help
- 89430A - 1BH - General Export License version (Retrofit unavailable)
- 89430A - 1BP - MIL STD 45662A Calibration with Test Data (Retrofit unavailable)
- 89430A - HP 41800A - Active probe 5 Hz - 500 MHz, 100 kΩ / 3 pF input impedance
- 89430A - HP 1141A - Active differential probe dc - 200 MHz, 1 MΩ / 7 pF input impedance
- 89430A - HP 10020A - Resistive divider probe 1:1, 10:1 or 100:1, for 50Ω systems
- 89430A - HP 3488A - Switch control unit
- 89430A - HP 3235A - Switch control unit
- 89430A - HP 8447D - Preamplifier 25 dB gain, 100 kHz - 1.3 GHz, NF <8.5 dB
- 89430A - HP 8449D - Preamplifier 25 dB gain, 100 kHz - 1.8 GHz, NF <8.5 dB
- 89430A - HP 11852B Opt. CO4 - 50Ω - 75Ω minimum loss pad, matches 50Ω analyzer input to 75Ω environment
- 89430A - HP 89450A - DMCA Radio Test Personality (Requires option AYA)
- 89430A - HP 89451A - Radio Test Personality (Requires option AYA)
- 89430A - HP 89400+24C - Scheduled course, open enrollment; presented at HP location
- 89430A - HP 89400+24Y - Dedicated course, closed enrollment; presented at your site
| Model | 89430A |
|---|
Le Keysight (Agilent) 89430A est un module RF de 1,8 GHz conçu pour être utilisé avec le 89410A afin de constituer le système d’analyseur de signaux vectoriels 89440A. Il intègre une source interne pour des capacités d'analyse RF précises.
Cette section RF améliore l'analyse du signal grâce à une intégration transparente, des performances robustes et une compatibilité étendue. Idéale pour les environnements de R&D et de production.
Testwall peut fournir le Keysight (Agilent) 89430A d’occasion, entièrement testé. Avec un support expert et une livraison mondiale, Testwall garantit une instrumentation performante, fiable et un service de qualité. Veuillez nous contacter si vous avez besoin d’un étalonnage ou d’une réparation du Keysight (Agilent) 89430A.