Magna Power TSD600-72

| Attribut | Valeur |
|---|---|
| Tension de sortie | 600 V |
| Courant de sortie | 72 A |
| Puissance de sortie | 43 200 W (43,2 kW) |
| Tension d'entrée | 208/240/480 V CA, triphasé |
| Régulation de tension | 0,05 % de la pleine échelle |
| Régulation du courant | 0,1 % de la pleine échelle |
| Interface de programmation | RS-232, RS-485, GPIB, Ethernet (en option) |
| Mode de fonctionnement | Tension constante / Courant constant (CV/CC) |
| Refroidissement | Refroidissement par air forcé |
| Format | Montage en rack 19 pouces |
Magna Power TSD600-72 Options:
- TSD600-72 - SP - 208/240 Vac Single-Phase Input (5 kW Only)
- TSD600-72 - CAB1 - Cabinet and Integration (32" x 24" x 31.5", 12U)
- TSD600-72 - CAB2 - Cabinet and Integration (51.5" x 24" x 31.5", 24U)
- TSD600-72 - CAB3 - Cabinet and Integration (67" x 24" x 31.5", 30U)
- TSD600-72 - CAB4 - Cabinet and Integration (75" x 24" x 31.5", 36U)
- TSD600-72 - +ISO - High Isolation Output
- TSD600-72 - +HS - High Slew Rate Output
- TSD600-72 - +GPIB - IEEE-488 GPIB Interface
- TSD600-72 - +LXI - LXI TCP/IP Ethernet Interface
- TSD600-72 - PPPE - Photovoltaic Power Profile Emulation
- TSD600-72 - RS485 - RS-485 Converter
- TSD600-72 - UID - UID47 Universal Interface Device
- TSD600-72 - USB - USB Edgeport Converter
- TSD600-72 - +WC - Water Cooling
| Model | TSD600-72 |
|---|
RENT MAGNA-POWER TSD600-72
The Magna-Power Electronics TSD600-72 combines the best of DC power processing with microprocessor embedded control. Magna-Power Electronics' innovative power processing technology improves response, shrinks package size, and reduces cost. The Magna-Power TS Series power supplies are current-fed and are more tolerant to abusive loads than conventional switching power supplies. This technology allows the power supply to operate under short-circuit conditions, open-circuit conditions, and everything in between.
TS Series power supplies offer both master/slave parallel and series operation. This enables two or more power supplies to be placed in parallel for increased output cur or in series for increased output voltage. With master/slave operation, power supplies operate at near equal voltage and current.
TS Series power supplies can operate as a voltage source or cur source depending on the control settings and load conditions. If the power supply is operating as a voltage source and the load increases to a point beyond the cur command setting, the power supply automatically crosses over to cur mode control and operates as a cur source at that setting.
Specifications of the Magna-Power TSD600-72 High Voltage Power Supply include:
Input:
- AC Input Nominal Voltage:
- 480 Vac, 3Φ (operating range 432 - 528 Vac)
- Frequency: 50 Hz - 400 Hz (operating range 45 - 440 Hz)
- Power Factor: > 92% at maximum power
Output:
- 600V, 72A, 45kW
- Ripple: 250 mVrms
- Line Regulation:
- Voltage Mode: ± 0.004% of full scale
- Cur Mode: ± 0.02% of full scale
- Load Regulation
- Voltage Mode: ± 0.01% of full scale
- Cur Mode: ± 0.04% of full scale
- Load Transient Response: 2 ms to recover within ±1% of full scale output, with a 50% to 100% or 100% to 50% step load change
- Efficiency: 88% at full load
- Stability: ± 0.10% for 8 hrs. after 30 min. warmup
- Isolation:
- User inputs and outputs: referenced to earth ground
- Maximum input voltage to ground: ±2500 Vac
- Maximum output voltage to ground: ±1000 Vdc
- Maximum Slew Rate: 100 ms for output voltage change from 0 to 63% 100 ms for output cur change from 0 to 63%
- With High Slew Rate Option (+HS): 4 ms for output voltage change from 0 to 63% 8 ms for output cur change from 0 to 63%
- Bandwidth: 3 Hz for remote analog voltage programming 2 Hz for remote analog cur programming
- With High Slew Rate Option (+HS): 60 Hz for remote analog voltage programming 45 Hz for remote analog cur programming
- Dimensions: 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm)
- Weight: 349 lbs (158.3 kg
Control:
- Voltage Programming Accuracy: ± 0.075% of full scale voltage
- OVT Programming Accuracy: ± 0.075% of full scale voltage
- Cur Programming Accuracy: ± 0.075% of full scale current
- OCT Programming Accuracy: ± 0.075% of full scale current
- Voltage Readback Accuracy: ± 0.2% of full scale voltage
- Cur Readback Accuracy: ± 0.2% of full scale cur External
- Analog Programming and Monitoring Levels: 0 - 10 Vdc
- External Analog Output Impedances
- Voltage output monitoring: 100 Ω
- Cur output monitoring: 100 Ω
- +10 Vdc reference: 1 Ω
- External Digital Programming and Monitoring Limits:
- Input: 0 to 5 Vdc, 10k input inpedance
- Output: 0 to 5 Vdc, 5 mA drive capacity
- Remote Sense Limits: 3% maximum voltage drop from output to load
- Period Programming Limits: Minimum period: 10 ms Maximum period: 9997 sec