Megger ADX-15-RLC-PD

| Attribut | Valeur |
|---|---|
| Tension de test maximale | 15 kV |
| Méthode de mesure | RLC et détection des décharges partielles (PD) |
| Plage de mesure de capacité | 1 pF à 100 µF |
| Plage de mesure du facteur de dissipation (tan δ) | 0,0001 à 1 |
| Sensibilité de détection des décharges partielles | 1 pC |
| Fréquence de test | 15 Hz à 400 Hz |
| Interface de communication | USB, RS-232 |
| Alimentation électrique | 100 V à 240 V CA, 50/60 Hz |
| Conformité aux normes | IEC 60270, IEEE 400.3 |
| Conditions d'utilisation | Température : -10 °C à +50 °C, Humidité : jusqu'à 90 % sans condensation |
Megger ADX-15-RLC-PD Options:
- ADX-15-RLC-PD - 1013-911 - Standard ADX with DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests only - 4 kV (ADX 4)
- ADX-15-RLC-PD - 1013-912 - Standard ADX with DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests only - 6 kV (ADX 6)
- ADX-15-RLC-PD - 1013-913 - Standard ADX with DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests only - 12 kV (ADX 12)
- ADX-15-RLC-PD - 1013-914 - Standard ADX with DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests only - 15 kV (ADX 15)
- ADX-15-RLC-PD - 1013-916 - ADX with RLC (low voltage Resistance, Inductance, and Capacitance), DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests - 4 kV (ADX-4-RLC)
- ADX-15-RLC-PD - 1013-917 - ADX with RLC (low voltage Resistance, Inductance, and Capacitance), DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests - 6 kV (ADX-6-RLC)
- ADX-15-RLC-PD - 1013-918 - ADX with RLC (low voltage Resistance, Inductance, and Capacitance), DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests - 12 kV (ADX-12-RLC)
- ADX-15-RLC-PD - 1013-919 - ADX with RLC (low voltage Resistance, Inductance, and Capacitance), DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), and Surge tests - 15 kV (ADX-15-RLC)
- ADX-15-RLC-PD - 1013-920 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests - 4 kV (ADX-4-RLC-PD)
- ADX-15-RLC-PD - 1013-921 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests - 6 kV (ADX-6-RLC-PD)
- ADX-15-RLC-PD - 1013-922 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests - 12 kV (ADX-12-RLC-PD)
- ADX-15-RLC-PD - 1013-923 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests - 15 kV (ADX-15-RLC-PD)
- ADX-15-RLC-PD - 1013-925 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests, includes Power Pack Interface - 4 kV (ADX-4-RLC-PD-PPI)
- ADX-15-RLC-PD - 1013-926 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests, includes Power Pack Interface - 6 kV (ADX-6-RLC-PD-PPI)
- ADX-15-RLC-PD - 1013-927 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests, includes Power Pack Interface - 12 kV (ADX-12-RLC-PD-PPI)
- ADX-15-RLC-PD - 1013-928 - ADX with RLC, DC Insulation Resistance (IR, DA, PI), DC HiPot (standard, Step, Ramp), Surge, and Partial Discharge tests, includes Power Pack Interface - 15 kV (ADX-15-RLC-PD-PPI)
- ADX-15-RLC-PD - 1014-110 - Footswitch - Operators initiate tests using the foot switch rather than the ADX front panel test switch during coil testing
- ADX-15-RLC-PD - 1014-109 - Megger Baker Test Status Indication Light Equipment Stop (TSIL-ES) - Remote accessory box for ADX equipment stop with a button press; displays flashing red light when actively testing and green light when no testing is in progress
- ADX-15-RLC-PD - 1014-106 - ADX Standard Test Lead Set
- ADX-15-RLC-PD - 1014-107 - ADX Custom Test Lead Set
- ADX-15-RLC-PD - 1014-115 - Pelicase
- ADX-15-RLC-PD - 1014-117 - ADX Test Lead - 15 kV Black
- ADX-15-RLC-PD - 1014-114 - ADX Backpack
- ADX-15-RLC-PD - 1014-111 - ADX Keyboard
- ADX-15-RLC-PD - 1014-116 - ADX Test Lead - 15 kV Red and labeling kit
- ADX-15-RLC-PD - 1014-112 - ADX Front Cover
| Model | ADX-15-RLC-PD |
|---|
Le Megger ADX-15-RLC-PD Automated Static Motor Analyzer est conçu pour des diagnostics moteurs avancés, avec des câbles de test conformes IEC61010 évalués à 16 kV. Il prend en charge les tests RLC (Résistance, Inductance, Capacité), Résistance d’isolement DC (IR, DA, PI), HiPot DC (Standard, Step, Ramp), Surge et Décharge Partielle. L’appareil propose plusieurs modes—Manuel, Automatique ou Séquence—et intègre la gestion et la recherche d’actifs.
Grâce à la connectivité cloud PowerDB Dashboard et au logiciel ADX, les opérateurs bénéficient d’une configuration fluide, de réglages de test flexibles et d’une gestion efficace des parcours. Ce système garantit un environnement de test fiable et convivial.
Testwall peut fournir le Megger ADX-15-RLC-PD d’occasion, entièrement testé. Avec un support expert et une livraison mondiale, Testwall assure des instruments performants avec une fiabilité et une qualité de service inégalées. Veuillez nous contacter directement si vous avez besoin d’étalonnage ou de réparation du Megger ADX-15-RLC-PD.