Manufacturer Logo

Tektronix FCA3103

FabricantTektronix
ModèleFCA3103
ProduitFrequency Counter / Analyzer, 3 GHz, 3 Ch.
TypeProduit Reconditionné

 

twFCA3100

Tektronix FCA3100

twFCA3020

Tektronix FCA3020

Obtenir un devis
SKU
twFCA3103

Tektronix Frequency Analyzer

Tektronix FCA3103 Frequency Counter / Analyzer, 3 GHz, 3 Ch.

The Tektronix FCA3103 Timer/Counter/Analyzer Series pack many diffe functions into one feature-rich instrument. With industry-leading frequency and time resolution, the FCA Series comes standard with deep internal memory and a fast data transfer rate of 250k Samples/s to internal memory. In addition, the multi-parameter display shows auxiliary measurements alongside your main measurement to provide you with the results you need at a glance. With the industry's most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal.

The Tektronix FCA3103 Series offers a zero dead-time measurement technique and continuous time stamping of trigger events. This feature is vital for mechanical and medical measurements where every single cycle must be measured. The Tektronix FCA3103 Series offers a zero dead-time counter feature to continuously stream measurement data over the GPIB/USB bus during, not after, measurement. This creates a dynamic measurement and analysis system.

 

Features and Specifications of the Tektronix FCA3103 includes:

  • 3 GHz Timer
  • 3 Input Channels
  • 50 ps Single-shot Time Resolution
  • 12 Digit/s Frequency Resolution
  • 0.001 ° Phase Resolution
  • 3 mV or better Voltage Resolution
  • Optional 5×10 €“8 High-stability Oven Time Base
  • 250k Sample/s Data Transfer Rate to Internal Memory(Up to 3.75M samples stored)
  • Up to 15k Sample/s Data Transfer Rate over USB/GPIB Bus(Block mode)
  • Up to 650 Individually Triggered Measurements/s
  • Automated Measurements: Frequency, Period, Ratio, Time Interval, Time Interval Error, Pulse Width, Rise/Fall
  • Time, Phase Angle, Duty Cycle, Maximum Voltage, Minimum Voltage, Peak-to-Peak Voltage
  • Multi-parameter Display
  • Trend Plot Mode
  • Measurement Statistics Mode
  • Histogram Mode
  • Allan Deviation
  • Zero Dead-time Frequency/Period Measurements
  • Programmable Pulse Output from 0.5 Hz to 50 MHz
  • Optional Rear-panel Inputs
  • USB Device and GPIB Ports on Rear Panel for Quick PC Connectivity
  • GPIB Interface Supports Full SCPI-compatible Programmability and offers an Emulation Mode for Plug-and-Play Replacement in Existing ATE Systems
  • External Arming Input
  • 10 MHz Reference Oscillator Output
  • Includes National Instrument's LabVIEW SignalExpress TE Limited Edition Software for Connecting Your Bench
  • Optional TimeView Software Available for Modulation Domain Analysis

 

No Related Posts

Retours

Si vous n’êtes pas entièrement satisfait de votre achat, il vous suffit de nous retourner l’article dans son état d’origine dans les 30 jours suivant la réception. Les articles retournés doivent être inutilisés et renvoyés dans leur emballage d’origine avec toute la documentation jointe. Nous procéderons à un remboursement complet à réception, à l’exception des frais de livraison initiaux. En alternative, si vous le préférez, nous pouvons échanger l’article.