Tektronix
Tektronix MDO3024
Oscilloscope, Mixed Domain, 200 MHz 4 Ch., 2.5 GS/s
200 MHz Bande passante
4 voies Nombre de voies analogiques
2,5 GS/s Taux d'échantillonnage
10 millions de points Longueur d'enregistrement
3 GHz Bande passante de l'analyseur de spectre RF

| Attribut | Valeur |
|---|---|
| Bande passante | 200 MHz |
| Nombre de voies analogiques | 4 voies |
| Taux d'échantillonnage | 2,5 GS/s |
| Longueur d'enregistrement | 10 millions de points |
| Bande passante de l'analyseur de spectre RF | 3 GHz |
| Résolution verticale | 8 bits |
| Écran | Écran tactile LCD couleur 9 pouces (228,6 mm) |
| Voies numériques (option) | 16 voies numériques (avec sonde optionnelle) |
| Interfaces de connectivité | USB, LAN (LXI), port hôte USB |
| Sensibilité verticale | 1 mV/div à 10 V/div |
Tektronix MDO3024 Options:
- MDO3024 - MDO3AFG - Arbitrary function generator with 13 predefined waveforms and arbitrary waveform generation
- MDO3024 - MDO3MSO - 16 digital channels; includes P6316 digital probe and accessories
- MDO3024 - MDO3SA - Increase spectrum analyzer input frequency range to 9 kHz – 3 GHz and capture bandwidth to 3 GHz
- MDO3024 - MDO3SEC - Enhanced instrument security to enable password protected control of turning on/off all instrument ports and instrument firmware update functionality
- MDO3024 - Opt. A0 - North America power plug (115 V, 60 Hz)
- MDO3024 - Opt. A1 - Universal Euro power plug (220 V, 50 Hz)
- MDO3024 - Opt. A2 - United Kingdom power plug (240 V, 50 Hz)
- MDO3024 - Opt. A3 - Australia power plug (240 V, 50 Hz)
- MDO3024 - Opt. A5 - Switzerland power plug (220 V, 50 Hz)
- MDO3024 - Opt. A6 - Japan power plug (100 V, 50/60 Hz)
- MDO3024 - Opt. A10 - China power plug (50 Hz)
- MDO3024 - Opt. A11 - India power plug (50 Hz)
- MDO3024 - Opt. A12 - Brazil power plug (60 Hz)
- MDO3024 - Opt. A99 - No power cord
- MDO3024 - Opt. L0 - English front panel label
- MDO3024 - Opt. L1 - French front panel overlay
- MDO3024 - Opt. L2 - Italian front panel overlay
- MDO3024 - Opt. L3 - German front panel overlay
- MDO3024 - Opt. L4 - Spanish front panel overlay
- MDO3024 - Opt. L5 - Japanese front panel overlay
- MDO3024 - Opt. L6 - Portuguese front panel overlay
- MDO3024 - Opt. L7 - Simplified Chinese front panel overlay
- MDO3024 - Opt. L8 - Traditional Chinese front panel overlay
- MDO3024 - Opt. L9 - Korean front panel overlay
- MDO3024 - Opt. L10 - Russian front panel overlay
- MDO3024 - Opt. L99 - No manual, English front panel label
- MDO3024 - Opt. C3 - Calibration Service 3 Years
- MDO3024 - Opt. C5 - Calibration Service 5 Years
- MDO3024 - Opt. D1 - Calibration Data Report
- MDO3024 - Opt. D3 - Calibration Data Report 3 Years (with Opt. C3)
- MDO3024 - Opt. D5 - Calibration Data Report 5 Years (with Opt. C5)
- MDO3024 - Opt. G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- MDO3024 - Opt. G5 - Complete Care 5 Years (includes loaner, scheduled calibration, and more)
- MDO3024 - Opt. R5 - Repair Service 5 Years (including warranty)
- MDO3024 - MDO3BW2T34 - Bandwidth upgrade from 200 MHz to 350 MHz
- MDO3024 - MDO3BW2T54 - Bandwidth upgrade from 200 MHz to 500 MHz
- MDO3024 - MDO3BW2T104 - Bandwidth upgrade from 200 MHz to 1 GHz
- MDO3024 - MDO3BW3T54 - Bandwidth upgrade from 350 MHz to 500 MHz
- MDO3024 - MDO3BW3T104 - Bandwidth upgrade from 350 MHz to 1 GHz
- MDO3024 - MDO3BW5T104 - Bandwidth upgrade from 500 MHz to 1 GHz
- MDO3024 - MDO3BND - Application module enabling all functionality of MDO3AERO, MDO3AUDIO, MDO3AUTO, MDO3COMP, MDO3EMBD, MDO3FLEX, MDO3LMT, MDO3PWR and MDO3USB in a single module
- MDO3024 - MDO3AERO - Aerospace Serial Triggering and Analysis Module (MIL-STD-1553 and ARINC-429)
- MDO3024 - MDO3AUDIO - Audio Serial Triggering and Analysis Module (I2S, LJ, RJ, and TDM)
- MDO3024 - MDO3AUTO - Automotive Serial Triggering and Analysis Module (CAN, CAN FD, and LIN)
- MDO3024 - MDO3COMP - Computer Serial Triggering and Analysis Module (RS-232/422/485/UART)
- MDO3024 - MDO3EMBD - Embedded Serial Triggering and Analysis Module (I2C and SPI)
- MDO3024 - MDO3FLEX - FlexRay Serial Triggering and Analysis Module
- MDO3024 - MDO3USB - USB Serial Triggering and Analysis Module (low-speed, full-speed, and high-speed)
- MDO3024 - MDO3PWR - Power Analysis Application Module
- MDO3024 - MDO3LMT - Limit and Mask Testing Application Module
| Model | MDO3024 |
|---|
Le Tektronix MDO3024 est un oscilloscope mixte domaine 4 canaux de 200MHz avec analyseur de spectre intégré, offrant un échantillonnage de 2,5GS/s et une mémoire de 10M. Il est personnalisable et conforme aux normes de sécurité internationales.
Idéal pour le débogage de signaux complexes, il prend en charge les fonctions mathématiques, l’analyse logique/protocole, AFG, avec des connexions USB, Ethernet, VGA et plus.
Testwall peut fournir le Tektronix MDO3024 d’occasion, entièrement testé. Avec un support expert et une livraison mondiale, Testwall garantit des instruments haute performance avec une fiabilité et un service inégalés. Contactez-nous pour la calibration ou la réparation du Tektronix MDO3024.