Amplifier Research 1500T2G8A

| Attributo | Valore |
|---|---|
| Potenza di uscita | 1500 W CW |
| Gamma di frequenza | 0,8 GHz – 2,0 GHz |
| Guadagno minimo | 45 dB |
| Impedenza di ingresso/uscita | 50 Ohm |
| Potenza di ingresso massima | 0 dBm (1 mW) |
| Armoniche e spurie | -10 dBc massimo |
| Connettore di ingresso | Type N femmina |
| Connettore di uscita | Type N femmina |
| Alimentazione richiesta | 220 V CA, 50/60 Hz monofase |
| Raffreddamento | Raffreddamento a liquido |
Amplifier Research 1500T2G8A Options:
- 1500T2G8A - P1 - 190-255 VAC, 3 phase, delta (4 wire), 50/60 Hz, 11 KVA maximum
- 1500T2G8A - P2 - 360-435 VAC, 3 phase, WYE (5 wire), 50/60 Hz, 11 KVA maximum. CE marked to comply with EMC European Directive 89/336/EEC for operation inside a shielded room
- 1500T2G8A - S1F - Input, forward and reflected power sample ports on front panel
- 1500T2G8A - S2B - Supplied with larger castor wheels and mounted on a rugged base that facilitates use of a forklift to move the TWTA. Add 46 kg (100 lbs) to weight, add 76 cm (3 inches) to height and 26 cm (10 inches) to width at base
L’Amplifier Research 1500T2G8A è un amplificatore TWT ad alta potenza che fornisce 1 500 W in onda continua (CW) nell’intervallo di frequenza da 2 a 8 GHz. Con raffreddamento ad aria robusto, diagnostica sul pannello frontale e design modulare, garantisce funzionamento affidabile e manutenzione semplificata in ambienti di test impegnativi.
Progettato per test radar, verifiche di immunità EMC ad alta potenza e generazione di segnali in banda satellitare, il 1500T2G8A offre prestazioni a banda larga stabili ottimizzate per un utilizzo intensivo.
Testwall può fornire l’Amplifier Research 1500T2G8A usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumentazione ad alte prestazioni con affidabilità e qualità del servizio senza pari. Contattateci direttamente se avete bisogno di calibrazione o riparazione del 1500T2G8A.