Anritsu MA2421A

| Attributo | Valore |
|---|---|
| Intervallo di Frequenza | 10 MHz - 18 GHz |
| Intervallo di Potenza | -70 dBm a +20 dBm |
| Tipo di Rilevatore | Diodo rilevatore a risposta rapida |
| Connettore RF | APC-3.5 (femmina) |
| Impedenza | 50 Ohm |
| Tempo di Risposta | Inferiore a 400 ns |
| Incertezza di Calibrazione | ±1,0 dB |
| Temperatura Operativa | 0°C a +55°C |
| Compatibilità | Compatibile con misuratori di potenza Anritsu serie ML2400 |
| Dimensioni (L x P x A) | 19 mm x 19 mm x 76 mm (circa) |
Anritsu MA2421A Options:
- ML2490A - 06 - Rear Mount Input A
- ML2490A - 07 - Rear Input A and Reference
- ML2490A - 08 - Rear Mount Inputs A, B and Reference
- ML2490A - 09 - Rear Mount Inputs A and B
- ML2490A - 33 - Extra Operating Manual
- ML2490A - 34 - Extra Programming Manual
- ML2490A - 37 - Electronic Manuals (deletes paper version from shipment)
- ML2490A - 98 - Calibration to Z540, ISO Guide 25
- ML2490A - 99 - Premium Calibration
- ML2480A - 06 - Rear Mount Input A
- ML2480A - 07 - Rear Input A and Reference
- ML2480A - 08 - Rear Mount Inputs A, B and Reference
- ML2480A - 09 - Rear Mount Inputs A and B
- ML2480A - 15 - Factory Fitted 50MHz and 1GHz Calibrator (required by MA2411B Sensor)
- ML2480A - 15R - Retro Fit Calibrator Kit
- ML2480A - 33 - Extra Operating Manual ML2487/8A
- ML2480A - 34 - Extra Programming Manual ML2487/8A
- ML2480A - 35 - Extra Operating Manual: Japanese
- ML2480A - 36 - Extra Programming Manual: Japanese
- ML2480A - 37 - Electronic Manuals only (deletes paper version from shipment)
- ML2480A - 98 - Calibration to Z540, ISO Guide 25
- ML2480A - 99 - Premium Calibration
- ML2400A - 32A - Maintenance Manual ML2480/90A Series
- ML2400A - 31A - Option 31, Extra Operation/Prog manual ML2480A
- ML2400A - 06 - Rear Mount Input A on ML2437A
- ML2400A - 07 - Rear Input A and Reference on ML2437A
- ML2400A - 08 - Rear Mount Inputs A, B and Reference
- ML2400A - 09 - Rear Mount Inputs A and B on ML2438A
- ML2400A - 11 - NiMH Battery with Desktop Charger
- ML2400A - 11A - NiMH Battery with Desktop Charger (for use in Japan only)
- ML2400A - 22 - 3m Sensor Cable
- ML2400A - 23 - 5m Sensor Cable
- ML2400A - 24 - 10m Sensor Cable
- ML2400A - 25 - 30m Sensor Cable
- ML2400A - 26 - 50m Sensor Cable
- ML2400A - 27 - 100m Sensor Cable
- ML2400A - 30 - Extra Operation Manual ML2437/8A
- ML2400A - 98 - Calibration to Z540, ISO Guide 25
- ML2400A - 99 - Premium Calibration
- ML2400A - 30A - Option 30, Extra Operation/Prog manual (For use in Japan, only)
- ML2400A - 10585-00003 - Maintenance Manual ML2400A Series
- ML2400A - 33 - Extra Operating & Programming Manual ML2437/8A
- MA2499B - MA2499B - Anritsu 4700 & 4600 Series Sensor Adapter
- ML2400A - 01 - Rack Mount, single unit
- ML2400A - 03 - Rack Mount, side by side
- ML2400A - 05 - Front Bail Handle
- ML2400A - 12 - Front Panel Cover
- ML2400A - 20 - Spare 1.5m Sensor Cable
- ML2400A - 21 - 0.3m Sensor Cable
- ML2400A - 28 - RS232 Bootload Cable
- ML2400A - 29 - Bulkhead Adapter
- MA2418A - MA2418A - 50 MHz Reference Oscillator with Power Supply
- MA2419A - MA2419A - Range Calibrator
- MA2497A - MA2497A - Agilent/HP84xxA Series Sensor Adaptor
- MA2421A - 760-209 - Hardside Transit Case
- MA2421A - D41310 - Soft Carry Case with Shoulder Strap
| Model | MA2421A |
|---|
L’Anritsu MA2421A è un sensore di potenza termico basato su principio Seebeck, che fornisce letture precise di potenza media vera da 100 kHz a 18 GHz, da –30 dBm a +20 dBm, con elevata linearità, stabilità e basso ritorno di segnale grazie alla calibrazione dinamica tramite EEPROM integrato.
Ideale per applicazioni RF e microonde, presenta tempi di salita/discesa rapidi < 4 ms, rilevamento indipendente dalla forma d’onda in stile termocoppia e ampio intervallo dinamico di 50 dB per prestazioni affidabili in ambienti di test diversi.
Testwall può fornire l’Anritsu MA2421A usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità e qualità del servizio senza pari. Contattaci direttamente se hai bisogno di calibrazione o riparazione dell’Anritsu MA2421A.